Field fix / guideManual / ReferenceVendor-agnosticProcess Controlindustrial-automation

PID Loop Configuration — Engineering Guide

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 47 views

# PID Loop Configuration Proportional-Integral-Derivative (PID) control is the backbone of process automation. TSIMEREZIVO includes a full-featured PID function block that supports auto/manual switching with bumpless transfer, setpoint ramping, output limits, cascade control, and feed-forward. This guide covers configuration, tuning, and advanced strategies. 20 min ## PID Control Fundamentals ISA-51.1 PID Algorithm (Position Form) u(t) = Kp × e(t) + Ki × ∫e(t)dt + Kd × de(t)/dt | term | formula | desc | |---|---|---| | Proportional (Kp) | Kp × e(t) | React to current error. Higher Kp = faster response, but may overshoot. Too high → oscillation. | | Integral (Ki) | Ki × ∫e(t)dt | Eliminate steady-state offset. Accumulates error over time. Too high → windup and slow oscillation. | | Derivative (Kd) | Kd × de(t)/dt | Dampen sudden error changes. Reduces overshoot. Too high → noise amplification and instability. | where: `e(t) = SP − PV`  ·  SP = Setpoint  ·  PV = Process Variable  ·  u(t) = Controller Output (CV) ## TSIMEREZIVO PID Function Block Parameters | param | tag | type | desc | val | |---|---|---|---|---| | Process Variable | PV | REAL | Measured process value (4–20mA scaled to engineering units) | Sensor read | | Setpoint | SP | REAL | Desired process value. Operator setpoint in manual SP mode | Process design | | Output | CV | REAL | Controller output 0–100%. Connected to valve/VFD AO channel | 0–100 % | | Mode | MODE | BOOL | FALSE = Manual (operator controls CV), TRUE = Auto (PID controls CV) | FALSE (startup) | | Proportional Gain | Kp | REAL | Proportional gain. Start at 1.0, tune up until near-oscillation | 0.5–5.0 | | Integral Time | Ti | TIME | Integral time in seconds. Lower Ti = more integral action | T#30s–T#300s | | Derivative Time | Td | TIME | Derivative time. Use 0 for most loops. Enable for slow processes | T#0s (default) | | Output High Limit | CV_HI | REAL | Maximum CV output (valve fully open / VFD max frequency) | 100.0 | | Output Low Limit | CV_LO | REAL | Minimum CV output (valve minimum stop / VFD min frequency) | 0.0 or 5.0 | | SP Ramp Rate | SP_RAMP | REAL | Maximum SP change per minute. Prevents step changes from shocking process | 0 = disabled | | Anti-Windup | ANTI_WINDUP | BOOL | Enable integrator anti-windup when output is at limit. ALWAYS TRUE in production | TRUE | | Feed-Forward | FF | REAL | Feed-forward bias added to CV output. Compensates for measurable disturbances | 0.0 | ## Auto / Manual Mode Switching > **RULE-P1: Bumpless Transfer — Mandatory** — Switching a PID from Manual to Auto MUST use bumpless transfer: before enabling Auto, the internal integrator is pre-loaded with the current manual CV value. Without this, the controller will step the output to where the integral says it should be, causing a potentially dangerous step change on the control valve or VFD. The TSIMEREZIVO PID function block handles bumpless transfer automatically when ANTI_WINDUP=TRUE. ```st (* Manual Mode: operator can write directly to TIC201.CV *) TIC201.MODE := FALSE; (* FALSE = Manual *) TIC201.CV := 45.0; (* Operator opens valve to 45% *) (* Before switching to Auto: TSIMEREZIVO PID block pre-loads integrator *) (* (This happens internally — no code required from engineer) *) (* Switch to Auto: integrator starts from current CV = 45% *) TIC201.MODE := TRUE; (* TRUE = Auto *) (* PID now adjusts gradually from 45% to maintain SP *) (* No bump, no step change on TIC201.CV output *) (* Good practice: Log the mode switch *) (* TSIMEREZIVO audit log records mode change automatically via RULE-P5 *) ``` ## Step-Response Tuning (Ziegler-Nichols Open Loop) ### Step 1 — Put Loop in Manual Mode Switch the PID to Manual. Let the process reach a stable steady state (PV flat for 5+ minutes). Note the current CV% and the stable PV value. ### Step 2 — Make a Step Change Apply a step change to the CV — typically 10% up or down. In TSIMEREZIVO, adjust the Manual CV value in the faceplate from e.g. 45% to 55%. Record the time of the step. ### Step 3 — Record the Step Response Watch the trend. Record: - **Dead time (L)**: Time from the step until PV starts to move - **Rise time / time constant (τ)**: Time for PV to reach 63.2% of its final change - **Process gain (Kp_process)**: ΔPV / ΔCV (e.g. 8°C / 10% = 0.8 °C/%) ### Step 4 — Calculate Ziegler-Nichols PID Parameters ```text Kp = 0.9 × (τ / (Kp_process × L)) Ti = 3.33 × L (integral time in seconds) Td = 0 (derivative — omit for most flow/pressure loops) Example: L = 8s, τ = 45s, Kp_process = 0.8 °C/% Kp = 0.9 × (45 / (0.8 × 8)) = 0.9 × (45 / 6.4) = 6.3 Ti = 3.33 × 8 = 26.7s → use T#27s in TSIMEREZIVO ``` ## Cascade Control Cascade control uses two PID controllers — a primary (outer) loop controlling the main process variable, and a secondary (inner) loop that executes faster and compensates for inner disturbances. The primary loop's output becomes the setpoint for the secondary loop. *[Interactive diagram — view in the TSIMEREZIVO docs]* ```st (* PRIMARY LOOP — Temperature outer controller *) TIC201.PV := TT201_PV; (* Temperature PV from thermocouple *) TIC201.SP := 120.0; (* Desired reactor temperature 120°C *) TIC201.MODE := TRUE; (* Auto *) (* PRIMARY loop output = setpoint for secondary *) FIC401.SP := TIC201.CV; (* PrimaryOut drives cooling water flow SP *) (* SECONDARY LOOP — Flow inner controller (faster — 100ms cycle) *) FIC401.PV := FT401_PV; (* Cooling water flow m³/h *) FIC401.MODE := TRUE; (* Auto — SP set by primary loop *) (* FIC401.CV drives XV-401 cooling water valve *) ``` ### Related Guides | href | label | desc | |---|---|---| | /dashboard/docs/structured-text | Structured Text | Write the TSIMEREZIVO_PID function block in ST | | /dashboard/docs/drum-level-3-element | 3-Element Drum Level | Classic cascade application for boiler drum | | /dashboard/docs/faceplate-design | PID Faceplate | Design the operator-facing PID control panel |

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library