Alternating Lamp — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 42 views
# Alternating Lamp — Usage Guide
## Overview
Two-lamp alternating flash pattern for beacons, warnings, or demonstration panels.
## Commissioning
1. Set flash period to the required visual cadence
2. Add output feedback monitoring if lamp integrity is safety-relevant
---
## Control Logic — Vendor-Agnostic Pseudocode
# Alternating Lamp — Logic
## Standards: IEC 61131-3
## Scan Rate: 100ms | Pattern: alternating flash outputs
```
ROUTINE: AlternatingLamp
SCAN_RATE: 100ms
IF ENABLE THEN
FLASH_TMR := FLASH_TMR + 1
IF FLASH_TMR >= FLASH_PERIOD_TICKS THEN
FLASH_TMR := 0
TOGGLE := NOT TOGGLE
END_IF
LAMP_A := TOGGLE
LAMP_B := NOT TOGGLE
ELSE
LAMP_A := FALSE
LAMP_B := FALSE
END_IF
HMI_ENABLE := ENABLE
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
ENABLE,Alternating Lamp Enable,BOOL,input,,,,FALSE,
FLASH_TMR,Flash Timer,INT,internal,,0,100000,0,
FLASH_PERIOD_TICKS,Flash Toggle Period,INT,internal,,0,100000,10,
TOGGLE,Alternating State,BOOL,internal,,,,FALSE,
LAMP_A,Lamp A Output,BOOL,output,,,,FALSE,DO:1:0.0
LAMP_B,Lamp B Output,BOOL,output,,,,FALSE,DO:1:0.1
HMI_ENABLE,HMI: Enable,BOOL,output,,,,FALSE,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_NONE,No active alarms defined for alternating lamp pattern,N/A,low,diagnostic,Add lamp-feedback alarms if field hardware supports it.,0s,Yes
```