Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Utilityindustrial-automation

Auto Car Washing — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 45 views

# Auto Car Washing — Usage Guide ## Overview Timed car wash sequence with soap, rinse, and dry stages. ## Commissioning 1. Verify vehicle position detection before allowing automatic cycle start 2. Tune each stage duration for site equipment and water pressure 3. Test E-stop drop-out of all outputs --- ## Control Logic — Vendor-Agnostic Pseudocode # Auto Car Washing — Logic ## Standards: IEC 61131-3 | ISA-88-style sequence ## Scan Rate: 100ms | Pattern: wash-rinse-dry sequence ``` ROUTINE: AutoCarWashing SCAN_RATE: 100ms CASE SEQ_STATE OF 0: IF START_CMD AND VEHICLE_IN_POSITION THEN SEQ_STATE := 1 END_IF 1: SOAP_CMD := TRUE; TMR := TMR + 1; IF TMR >= SOAP_TICKS THEN SOAP_CMD := FALSE; TMR := 0; SEQ_STATE := 2 END_IF 2: RINSE_CMD := TRUE; TMR := TMR + 1; IF TMR >= RINSE_TICKS THEN RINSE_CMD := FALSE; TMR := 0; SEQ_STATE := 3 END_IF 3: DRY_CMD := TRUE; TMR := TMR + 1; IF TMR >= DRY_TICKS THEN DRY_CMD := FALSE; TMR := 0; SEQ_STATE := 4 END_IF 4: COMPLETE := TRUE; IF ACK_CMD THEN COMPLETE := FALSE; SEQ_STATE := 0 END_IF END_CASE IF ESTOP_ACTIVE THEN SOAP_CMD := FALSE; RINSE_CMD := FALSE; DRY_CMD := FALSE; SET_ALARM(ALM_ESTOP, CRITICAL) END_IF HMI_SEQ_STATE := SEQ_STATE END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address START_CMD,Wash Start Command,BOOL,input,,,,FALSE, ACK_CMD,Sequence Complete Acknowledge,BOOL,input,,,,FALSE, VEHICLE_IN_POSITION,Vehicle in Wash Position,BOOL,input,,,,FALSE,DI:0:0.0 ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.1 SEQ_STATE,Wash Sequence State,INT,internal,,0,4,0, TMR,Sequence Step Timer,INT,internal,,0,100000,0, SOAP_TICKS,Soap Step Duration,INT,internal,,0,100000,100, RINSE_TICKS,Rinse Step Duration,INT,internal,,0,100000,100, DRY_TICKS,Dry Step Duration,INT,internal,,0,100000,150, SOAP_CMD,Soap Command,BOOL,output,,,,FALSE,DO:1:0.0 RINSE_CMD,Rinse Command,BOOL,output,,,,FALSE,DO:1:0.1 DRY_CMD,Dry Command,BOOL,output,,,,FALSE,DO:1:0.2 COMPLETE,Sequence Complete,BOOL,internal,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_SEQ_STATE,HMI: Sequence State,INT,output,,0,4,0, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Wash sequence halted immediately.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library