Cargo Elevator — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 49 views

# Cargo Elevator — Usage Guide ## Overview Basic cargo elevator motion template with overload protection and door-closed interlock. ## Commissioning 1. Verify top and bottom position switches 2. Confirm overload and door-open conditions inhibit motion 3. Test E-stop drop-out of both motor direction commands --- ## Control Logic — Vendor-Agnostic Pseudocode # Cargo Elevator — Logic ## Standards: IEC 61131-3 ## Scan Rate: 20ms | Pattern: platform move with door interlocks ``` ROUTINE: CargoElevator SCAN_RATE: 20ms MOVE_PERMIT := DOOR_CLOSED AND NOT ESTOP_ACTIVE AND NOT OVERLOAD IF CALL_UP AND MOVE_PERMIT AND NOT AT_TOP THEN MOTOR_UP_CMD := TRUE END_IF IF CALL_DOWN AND MOVE_PERMIT AND NOT AT_BOTTOM THEN MOTOR_DOWN_CMD := TRUE END_IF IF AT_TOP THEN MOTOR_UP_CMD := FALSE END_IF IF AT_BOTTOM THEN MOTOR_DOWN_CMD := FALSE END_IF IF ESTOP_ACTIVE OR OVERLOAD OR NOT DOOR_CLOSED THEN MOTOR_UP_CMD := FALSE MOTOR_DOWN_CMD := FALSE END_IF IF OVERLOAD THEN SET_ALARM(ALM_OVERLOAD, HIGH) END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF HMI_TOP := AT_TOP HMI_BOTTOM := AT_BOTTOM END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address CALL_UP,Call Up Request,BOOL,input,,,,FALSE, CALL_DOWN,Call Down Request,BOOL,input,,,,FALSE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 OVERLOAD,Elevator Overload Input,BOOL,input,,,,FALSE,DI:0:0.1 DOOR_CLOSED,Door Closed Interlock,BOOL,input,,,,TRUE,DI:0:0.2 AT_TOP,Top Position Switch,BOOL,input,,,,FALSE,DI:0:0.3 AT_BOTTOM,Bottom Position Switch,BOOL,input,,,,TRUE,DI:0:0.4 MOVE_PERMIT,Elevator Move Permit,BOOL,calculated,,,,FALSE, MOTOR_UP_CMD,Motor Up Command,BOOL,output,,,,FALSE,DO:1:0.0 MOTOR_DOWN_CMD,Motor Down Command,BOOL,output,,,,FALSE,DO:1:0.1 ALM_OVERLOAD,Elevator Overload Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_TOP,HMI: At Top,BOOL,output,,,,FALSE, HMI_BOTTOM,HMI: At Bottom,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Elevator motion removed immediately.,0s,No ALM_OVERLOAD,OVERLOAD = TRUE,N/A,high,safety,Platform overload detected. Remove excess load before movement.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library