Engineering Library
Procedures, PLC and HMI code, drawings, and field-proven fixes shared by working controls and instrumentation engineers. Community contributions publish immediately and can be flagged for review. Membership is free — sign in to download, rate, and contribute.
126 published contributions
- Read more
Chemical Disinfection & Residual Monitoring — Control Design
Automatically inject chlorine or ozone into treated water to inactivate pathogens bacteria, viruses, protozoa . Maintain residual disinfectant 0.2–0.5 mg/L free chlorine throughout distribution system. Continuously monit…
TSIMEREZIVO Team · 42 views · 0 downloads
- Read more
Multi-Pump Distribution System with Pressure Regulation — Control Design
Manage water distribution from treatment plant to customers via a variable speed pump network . System must maintain constant downstream pressure despite fluctuating demand day: 700 m³/h peak; night: 80 m³/h base . Uses …
TSIMEREZIVO Team · 64 views · 0 downloads
- Read more
Filtration System Control — Control Design
Automated control of a multi media pressure filtration system for potable water or tertiary wastewater treatment. Covers normal filtration, turbidity monitoring, backwash sequencing, and filter to waste FTW operations.
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Pump Station Control — Control Design
Automated control of a multi pump wet well station for raw sewage, stormwater, or potable water transfer. Covers duty/standby pump sequencing, wet well level control, and dry run protection.
TSIMEREZIVO Team · 50 views · 0 downloads
- Read more
Soft-Start Electronic Motor Ramp — Control Design
Smooth acceleration of 3 phase AC induction motors using solid state soft starter to reduce inrush current, mechanical shock, and transmission wear. Applications: conveyor drive, pump motor, fan, compressor startup, ener…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Dual Equipment Switchover (Automatic Failover) — Control Design
Switch load automatically from Primary → Secondary motor if Primary fails OR Primary demand exceeds capacity.
TSIMEREZIVO Team · 37 views · 0 downloads
- Read more
Pump Control (Lead/Lag - Duty Cycling) — Control Design
Two identical pumps sharing duty load. Automatically alternates every 24 hours configurable to equalize wear and extend equipment life.
TSIMEREZIVO Team · 49 views · 0 downloads
- Read more
Duty Standby Alternation — PLC Control Template
Implements API 610 / ISO 13709 duty/standby pump logic with runtime equalised automatic alternation, soft handover overlap start , and auto failover within 2 seconds of duty pump loss.
TSIMEREZIVO Team · 36 views · 0 downloads
- Read more
Three Element Drum Level — PLC Control Template
This template implements the industry standard three element drum level control strategy for steam boiler applications. It is the most widely used drum level control method in power generation, typically employed for boi…
TSIMEREZIVO Team · 46 views · 0 downloads