Design Document
Community-shared design document from working engineers — 55 items. Read free, sign up to download.
Turbine Governor Control — Control Design
Speed and load control of a steam or gas turbine via the electro-hydraulic governor. Covers isochronous speed control (islanding), droop control (grid-connected), acceleration limiting, overspeed protection, and valve position control.
TSIMEREZIVO Team · 97 views · 0 downloads
Pressure Reducing Valve (Pilot-Operated) — Control Design
Reduce a high-pressure supply to a lower, regulated downstream pressure via a pilot-operated proportional valve.
TSIMEREZIVO Team · 65 views · 0 downloads
Fan Control (Single — On/Off Soft-Start) — Control Design
Start/stop a single ventilation or cooling fan with smooth acceleration and current limiting. Fan startup stress reduced dramatically via soft-start.
TSIMEREZIVO Team · 65 views · 0 downloads
Multi-Pump Distribution System with Pressure Regulation — Control Design
Manage water distribution from treatment plant to customers via a **variable-speed pump network**. System must maintain constant downstream pressure despite fluctuating demand (day: 700 m³/h peak; night: 80 m³/h base). Uses pressure feedback and multiple pump stages to minimize e
TSIMEREZIVO Team · 62 views · 0 downloads
Air/Fuel Ratio Trim Cascade Control — Control Design
Fine-tune air/fuel ratio (lambda) for optimal combustion energy recovery while meeting NOₓ emissions limits. This is the **secondary loop extension** to Template 01 (Furnace Combustion Pressure), explicitly managing stoichiometric ratio and O₂ excess using continuous emissions mo
TSIMEREZIVO Team · 59 views · 0 downloads
Pulverized Coal Mill Outlet (PA) Flow Control — Control Design
Regulate primary air (PA) flow and temperature from the coal mill to maintain consistent coal-in-air concentration (fuel feed) to the furnace. The mill grinds raw coal into powder (~200 µm), mixes with hot air to fluidize particles, and transports coal-air suspension to burners.
TSIMEREZIVO Team · 53 views · 0 downloads
Proportional Control Valve Position Feedback Loop — Control Design
Position a proportional control valve spool accurately 0-100% using feedback-based regulation. Ensures valve opening matches command despite internal friction and spool nonlinearities.
TSIMEREZIVO Team · 51 views · 0 downloads
Gas Separation Vessel — Control Design
Three-phase separator removes liquids (oil + water) from raw gas stream under subsonic conditions. Liquid level is controlled via dump valve to prevent slugging downstream (compressor inlet) while maintaining interface between oil-water. Pressure is constrained by gas outlet back
TSIMEREZIVO Team · 50 views · 0 downloads
Pump Station Control — Control Design
Automated control of a multi-pump wet-well station for raw sewage, stormwater, or potable water transfer. Covers duty/standby pump sequencing, wet-well level control, and dry-run protection.
TSIMEREZIVO Team · 50 views · 0 downloads
Pump Control (Lead/Lag - Duty Cycling) — Control Design
Two identical pumps sharing duty load. Automatically alternates every 24 hours (configurable) to equalize wear and extend equipment life.
TSIMEREZIVO Team · 47 views · 0 downloads
Temperature PID Control Loop — Control Design
Precision temperature regulation via proportional-integral-derivative (PID) feedback control. Applies 0-100% output modulation to heating or cooling element based on error between setpoint and actual temperature.
TSIMEREZIVO Team · 47 views · 0 downloads
Soft-Start Electronic Motor Ramp — Control Design
Smooth acceleration of 3-phase AC induction motors using solid-state soft-starter to reduce inrush current, mechanical shock, and transmission wear. Applications: conveyor drive, pump motor, fan, compressor startup, energy recovery systems.
TSIMEREZIVO Team · 46 views · 0 downloads
Turbine Inlet (Main Steam) Pressure Regulator — Control Design
Regulate main steam pressure at the turbine inlet to exactly 175 bar (design point) to balance competing demands:
TSIMEREZIVO Team · 45 views · 0 downloads
Conveyor Load Monitoring & Auto-Speed Regulation — Control Design
A long-haul conveyor belt (crusher discharge → mill feed or stockpile) can fail if overloaded. This template monitors belt load (via motor current draw) and automatically modulates the belt speed downward if approaching maximum safe load, then ramps speed back up once the load de
TSIMEREZIVO Team · 45 views · 0 downloads
Filter Press & Sludge Dewatering Sequence — Control Design
Operate a plate-frame or belt filter press to dewater municipal wastewater sludge. Thickened sludge (4–6% solids) is pumped into filter press; applied pressure (10–20 bar) forces water out, leaving dry cake (15–25% solids) that requires 75% less hauling cost. Automate the batch c
TSIMEREZIVO Team · 45 views · 0 downloads
Aeration Basin Control — Control Design
Dissolved oxygen (DO) control in an activated-sludge aeration basin for biological wastewater treatment. Covers blower/diffuser DO control, MLSS (mixed liquor suspended solids) monitoring, ammonia-based aeration control (ABAC), and energy optimization.
TSIMEREZIVO Team · 45 views · 0 downloads
Main Condenser Pressure Control — Control Design
Maintain the main condenser absolute pressure at 0.08 bar (80 mbar) to maximize turbine expansion and power output. The condenser converts exhaust steam from the turbine back to liquid water through cooling. Lower absolute pressure = greater enthalpy drop = more power extracted f
TSIMEREZIVO Team · 45 views · 0 downloads
Activated Sludge Aeration Basin Control — Control Design
Maintain dissolved oxygen (DO) setpoint in activated sludge reactor tank through automatic aeration control. The aeration basin is the **heart of wastewater treatment**, where microorganisms consume organic pollutants (BOD) under aerobic conditions. Precise DO control maximizes t
TSIMEREZIVO Team · 45 views · 0 downloads
Emergency Shutdown (E-Stop) Logic — Control Design
Implement a hardwired emergency stop circuit that cuts power to all dangerous motors/actuators
TSIMEREZIVO Team · 45 views · 0 downloads
Deaerator Heater Level Control — Control Design
Maintain the deaerator feed water tank at a constant level (typically 50–60% of vessel) to ensure reliable suction pressure for the boiler feedwater pump (NPSH—Net Positive Suction Head availability). The deaerator also heats feed water to ~160°C and removes dissolved oxygen (< 7
TSIMEREZIVO Team · 45 views · 0 downloads
Economizer Outlet Temperature Control — Control Design
Maintain boiler feedwater temperature exiting the economizer (exhaust gas heat exchanger) at 210–220°C to preheat incoming cold feed water from the deaerator (160°C). This recovers 10–15% of the boiler's thermal energy that would otherwise be lost up the stack, improving overall
TSIMEREZIVO Team · 45 views · 0 downloads
HVAC Control — AHU and Chiller Plant — Control Design
Building Management System (BMS) control of an Air Handling Unit (AHU) and chilled water plant serving a commercial or industrial facility. Covers supply air temperature, mixed-air economizer, variable-volume supply air, and chiller plant sequencing.
TSIMEREZIVO Team · 44 views · 0 downloads
Subsea Umbilical Fault Isolation — Control Design
A subsea production manifold is connected to topside via umbilical (hydraulic control lines, power cables, fiber optics bundled). If umbilical ruptures, hydraulic pressure is lost, and all remotely-operated valves (ROVs) go to fail-safe (closed). An automatic Emergency Disconnect
TSIMEREZIVO Team · 43 views · 0 downloads
Boiler Feedwater Pump Pressure Control — Control Design
Maintain boiler feedwater pump discharge pressure at precisely 180–200 bar to overcome boiler steam drum pressure (175 bar at design) plus pipe friction losses (~15–20 bar) while minimizing energy waste. Too high = relief valve spills energy; too low = boiler couldn't fill; too d
TSIMEREZIVO Team · 42 views · 0 downloads
Crusher Jaw Gap & Feed Rate Optimization — Control Design
A jaw crusher (belt-fed ore hopper → primary crusher → stockpile) must maintain optimal jaw gap (2–6 cm typical) to maximize throughput while preventing overload (motor stall, frame damage). Jaw gap is adjustable via eccentric pin or hydraulic actuator. Tight gap = fine product b
TSIMEREZIVO Team · 42 views · 0 downloads
Chemical Disinfection & Residual Monitoring — Control Design
Automatically inject chlorine or ozone into treated water to inactivate pathogens (bacteria, viruses, protozoa). Maintain residual disinfectant (0.2–0.5 mg/L free chlorine) throughout distribution system. Continuously monitor residual with sensor feedback; adjust pump speed to ho
TSIMEREZIVO Team · 42 views · 0 downloads
Flow Control Loop (PID-Based) — Control Design
Maintain constant flow rate via proportional valve position or pump speed modulation. Independent of downstream pressure variations.
TSIMEREZIVO Team · 42 views · 0 downloads
Pressure Control Loop (PID-Based) — Control Design
Maintain system pressure at setpoint via proportional valve modulation. Prevents overpressure conditions and minimizes pressure oscillations.
TSIMEREZIVO Team · 42 views · 0 downloads
Vision-Guided Inspection & QA — Control Design
Automated optical inspection of manufactured parts using machine vision (camera + image processing) to detect defects, classify products, and trigger downstream quality actions (accept/reject/rework). Applications: electronics assembly, printed circuit board inspection, pharmaceu
TSIMEREZIVO Team · 41 views · 0 downloads
Packaging Line Sequencing & Coordination — Control Design
Synchronize multi-zone conveyor line with intermittent and continuous equipment (feeders, labelers, casepacker, palletizer) using zone-based state machines and encoder-based product tracking. Ensures smooth flow, prevents bottlenecks, and tracks product throughout line for tracea
TSIMEREZIVO Team · 41 views · 0 downloads
Filtration System Control — Control Design
Automated control of a multi-media pressure filtration system for potable water or tertiary wastewater treatment. Covers normal filtration, turbidity monitoring, backwash sequencing, and filter-to-waste (FTW) operations.
TSIMEREZIVO Team · 41 views · 0 downloads
Boiler Drum Level Control (3-Element Control) — Control Design
Three-element feedwater control for boiler drum level. Most safety-critical control in power plants.
TSIMEREZIVO Team · 41 views · 0 downloads
Furnace Combustion Pressure Control (O₂ Trim) — Control Design
Maintain furnace combustion air pressure within ±0.5 inches water column (±125 Pa) setpoint
TSIMEREZIVO Team · 41 views · 0 downloads
Batch Reactor Temperature Control — Control Design
Multi-stage reaction vessel temperature regulation via jacket heating and cooling water circulation. Typical applications include pharmaceutical synthesis, chemical polymerization, food processing, cosmetics blending.
TSIMEREZIVO Team · 40 views · 0 downloads
Gas Compression & Discharge Throttling — Control Design
Operate centrifugal or reciprocating gas compressor to maintain pipeline discharge pressure (setpoint typically 800–1500 psia) while protecting equipment from surge (compressor pre-surge condition) and limiting discharge temperature. As downstream demand fluctuates throughout the
TSIMEREZIVO Team · 40 views · 0 downloads
Pneumatic Valve Proportional Actuation — Control Design
Proportional control of directional control valves (solenoid-piloted spool valves) using pulse-width modulation (PWM) to achieve smooth actuation of pneumatic cylinders. Applications: press control, clamping, tool changer actuation, part positioning, pick-and-place systems.
TSIMEREZIVO Team · 39 views · 0 downloads
Variable Frequency Drive (VFD) Motor Control — Control Design
Modulate AC motor speed via frequency control. Enables energy savings, process precision, and soft-start capability.
TSIMEREZIVO Team · 39 views · 0 downloads
Superheater Outlet Temperature Control (Spray Water Attemperator) — Control Design
Maintain superheated steam outlet temperature at exactly setpoint (±3°C typical) using proportional
TSIMEREZIVO Team · 39 views · 0 downloads
Crude Oil Tank Level & Custody Transfer Metering — Control Design
Automatically measure crude oil tank inventory and compute **net barrels** (accounting for temperature, API gravity, water content) for custody transfer (ownership handoff between operator and buyer). Tank level measurement must be precise within ±0.1% to avoid billing disputes.
TSIMEREZIVO Team · 39 views · 0 downloads
Turbine Speed Governor (Proportional Throttle Valve Control) — Control Design
Regulate turbine inlet steam flow via a proportional throttle valve to maintain constant **turbine shaft speed**
TSIMEREZIVO Team · 38 views · 0 downloads
Wellhead Pressure Management & Production Optimization — Control Design
Automatically regulate wellhead backpressure (tubing head pressure) to optimize production rate while protecting subsurface equipment and preventing sand production. Most oil/gas wells produce under pressure differential: reservoir pressure − tubing pressure = driving force for f
TSIMEREZIVO Team · 38 views · 0 downloads
Robotic Arm Multi-Axis Position Tracking — Control Design
Coordinate multi-axis (typically 6) robotic arm positioning via simultaneous inverse kinematics, proportional servo valve control, and position feedback from joint encoders. Applications: welding, material handling,assembly, palletizing, spray painting.
TSIMEREZIVO Team · 38 views · 0 downloads
Pump Control (Single — On/Off with Protection) — Control Design
Start/stop a single electric motor pump with automatic overload protection, dry-run prevention, and fault reporting.
TSIMEREZIVO Team · 38 views · 0 downloads
Membrane Filtration with Automated Backwash Sequencing — Control Design
Operate crossflow ultrafiltration (UF) or microfiltration (MF) membrane systems with **pressure-driven permeate production** and **air-assisted backwashing** to restore permeability. Membrane fouling increases transmembrane pressure (TMP) over time; periodically reversing flow +
TSIMEREZIVO Team · 38 views · 0 downloads
Thickener Rake Torque & Underflow Clarity — Control Design
A thickener (settling tank, 20–50 m diameter) allows coarse solids to settle under gravity while water overflows as clarified product. A rotating rake mechanism slowly scrapes settled solids toward a central pump cone (underflow discharge). Rake torque monitoring indicates bed de
TSIMEREZIVO Team · 37 views · 0 downloads
Single Tank Level Control — Control Design
Simple level control for a single tank with pump or valve control. The most fundamental control loop in industrial automation.
TSIMEREZIVO Team · 37 views · 0 downloads
Dual Equipment Switchover (Automatic Failover) — Control Design
Switch load automatically from Primary → Secondary motor if Primary fails **OR** Primary demand exceeds capacity.
TSIMEREZIVO Team · 37 views · 0 downloads
Conveyor Belt Speed & Load Control — Control Design
Modular conveyor control with variable-frequency drive (VFD) motor, load sensing, anti-slip protection, and emergency stop interlocks. Common in packaging, food processing, automotive assembly, pharmaceutical manufacturing. Coordinates with upstream feeders and downstream equipme
TSIMEREZIVO Team · 36 views · 0 downloads
Load / Frequency Control (AGC / LFC) — Control Design
Automatic Generation Control (AGC) and Load-Frequency Control (LFC) for a generating unit participating in primary, secondary, and tertiary frequency response. Covers Area Control Error (ACE) computation, generation ramp management, tie-line bias control, and unit economic dispat
TSIMEREZIVO Team · 36 views · 0 downloads
Pipeline Flow Metering & Leak Detection — Control Design
Continuously measure crude/gas flow through transmission pipeline (orifice plate, turbine, or ultrasonic meter) and detect leaks by comparing expected flow (from surface + subsurface meters) against actual outlet flow. A 2% daily discrepancy (100 bopd on 5000 bopd line) could ind
TSIMEREZIVO Team · 35 views · 0 downloads
Lighting Automation Control — Control Design
Intelligent building lighting control integrating occupancy detection, daylight harvesting, scene management, and DALI bus control. Covers on/off scheduling, dimming, emergency lighting testing, and ASHRAE 90.1 compliance monitoring.
TSIMEREZIVO Team · 35 views · 0 downloads
Injection Mold Cavity Temperature Control — Control Design
Regulate injection mold cavity temperature via circulating heating/cooling water and proportional control valves. Critical for part dimensional stability, surface quality, and cycle time optimization in injection molding. Typical mold cavities maintain 60–120°C depending on resin
TSIMEREZIVO Team · 35 views · 0 downloads
Flotation Cell Pulp Density & Air Control — Control Design
Froth flotation cells separate valuable minerals (sulfides, oxides) from gangue (worthless rock) by floating mineral particles to the surface and collecting froth overflow. Cell performance depends critically on maintaining optimal pulp density (~25–35% solids by weight) and mana
TSIMEREZIVO Team · 34 views · 0 downloads
Energy Monitoring and Sub-Metering — Control Design
BMS-integrated energy monitoring, sub-metering, and automated demand response for commercial and industrial facilities. Covers kWh/kVArh metering, power quality monitoring, tenant sub-metering, peak demand management, and ISO 50001 KPI dashboards.
TSIMEREZIVO Team · 33 views · 0 downloads
Water Recycling Circuit & Density Balance — Control Design
Mining operations recycle water from thickener overflow back to upstream processes (crusher, mill) to conserve water and recover valuable solids from clarified water. However, recycled water carries suspended fines and reagents (flotation collectors, pH modifiers) that can change
TSIMEREZIVO Team · 32 views · 0 downloads