Pump Control (Lead/Lag - Duty Cycling) — Control Design

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 47 views

# Generic Module: Pump Control (Lead/Lag - Duty Cycling) **Version**: 1.0 **Complexity**: Medium **Industries**: Water, Oil & Gas, Chemical, Mining, HVAC **PLC Languages**: Ladder, ST, FBD --- ## 📋 Overview Two identical pumps sharing duty load. Automatically alternates every 24 hours (configurable) to equalize wear and extend equipment life. **Use When:** - ✅ Two identical centrifugal or gear pumps - ✅ Duty cycle alternation desired (maintenance scheduling) - ✅ One pump handles full demand; other is standby - ✅ No simultaneous dual-pump operation needed **Do NOT Use When:** - ❌ Both pumps must run simultaneously (use redundancy template) - ❌ Variable flow demands (use pressure control) - ❌ Different pump types (different pressure ratings) --- ## 🎯 Control Philosophy **Simple Rotation Strategy** ``` IF Pump_1_Runtime >= Pump_2_Runtime + 24 Hours → Make Pump_2 Active (Lead) → Make Pump_1 Standby (Lag) IF Pump_2_Runtime >= Pump_1_Runtime + 24 Hours → Make Pump_1 Active (Lead) → Make Pump_2 Standby (Lag) ``` **Benefits:** - ✅ Equal wear distribution (extends seal life) - ✅ Predictable maintenance scheduling - ✅ Reduced downtime (one pump always ready) - ✅ Simple logic, high reliability - ✅ Automatic switchover on demand --- ## 🏗️ Control Logic (Pseudocode) ```pascal PROGRAM Pump_Lead_Lag_Control VAR (* Settings *) Duty_Cycle_Hours : REAL := 24.0; (* Switch every 24h *) Start_Delay_Seconds : INT := 3; (* Wait before start *) (* Inputs *) Tank_Level : REAL; (* 0-100% *) Tank_Level_Low : REAL := 20.0; (* Low level threshold *) (* Pump 1 *) Pump_1_Runtime : REAL := 0.0; (* Hours *) Pump_1_Running : BOOL := FALSE; Pump_1_Fault : BOOL := FALSE; Pump_1_Current_OK : BOOL := TRUE; (* Pump 2 *) Pump_2_Runtime : REAL := 0.0; (* Hours *) Pump_2_Running : BOOL := FALSE; Pump_2_Fault : BOOL := FALSE; Pump_2_Current_OK : BOOL := TRUE; (* Active pump determination *) Active_Pump : INT := 1; (* 1 or 2 *) Idle_Pump : INT := 2; (* Start command delay *) Start_Delay_Counter : INT := 0; (* Status *) System_Running : BOOL := FALSE; Last_Switchover : DATE_TIME; END_VAR (* ─────────────────────────────────────────────────────── *) (* 1. DETERMINE ACTIVE PUMP (Lead/Lag Selection) *) (* ─────────────────────────────────────────────────────── *) IF Pump_1_Runtime >= (Pump_2_Runtime + Duty_Cycle_Hours) THEN (* Pump 1 has run 24h longer → switch to Pump 2 *) Active_Pump := 2; Idle_Pump := 1; ELSIF Pump_2_Runtime >= (Pump_1_Runtime + Duty_Cycle_Hours) THEN (* Pump 2 has run 24h longer → switch to Pump 1 *) Active_Pump := 1; Idle_Pump := 2; END_IF; (* ─────────────────────────────────────────────────────── *) (* 2. LOW LEVEL DETECTION (Start Pump) *) (* ─────────────────────────────────────────────────────── *) IF Tank_Level < Tank_Level_Low THEN (* Increment debounce counter *) Start_Delay_Counter := Start_Delay_Counter + 1; (* Wait 3 seconds before issuing start *) IF Start_Delay_Counter >= Start_Delay_Seconds THEN (* Determine which pump to start *) IF Active_Pump = 1 THEN Pump_1_Running := TRUE; Pump_2_Running := FALSE; ELSE Pump_2_Running := TRUE; Pump_1_Running := FALSE; END_IF; System_Running := TRUE; Start_Delay_Counter := 0; END_IF; ELSE (* Level OK → stop pump *) Pump_1_Running := FALSE; Pump_2_Running := FALSE; System_Running := FALSE; Start_Delay_Counter := 0; END_IF; (* ─────────────────────────────────────────────────────── *) (* 3. RECORD RUNTIME (Accumulate Hours for Rotation) *) (* ─────────────────────────────────────────────────────── *) IF Pump_1_Running THEN Pump_1_Runtime := Pump_1_Runtime + (SCAN_TIME_MILLISEC / 3600000.0); END_IF; IF Pump_2_Running THEN Pump_2_Runtime := Pump_2_Runtime + (SCAN_TIME_MILLISEC / 3600000.0); END_IF; (* ─────────────────────────────────────────────────────── *) (* 4. FAULT DETECTION (Current Monitoring) *) (* ─────────────────────────────────────────────────────── *) Pump_1_Fault := Pump_1_Running AND (NOT Pump_1_Current_OK); Pump_2_Fault := Pump_2_Running AND (NOT Pump_2_Current_OK); (* If active pump faults, try standby *) IF Active_Pump = 1 AND Pump_1_Fault THEN Pump_1_Running := FALSE; Pump_2_Running := TRUE; (* Log fault event *) END_IF; IF Active_Pump = 2 AND Pump_2_Fault THEN Pump_2_Running := FALSE; Pump_1_Running := TRUE; (* Log fault event *) END_IF; (* ─────────────────────────────────────────────────────── *) (* 5. OUTPUTS *) (* ─────────────────────────────────────────────────────── *) WRITE_DIGITAL_OUTPUT(DO_PUMP_1_CMD, Pump_1_Running); WRITE_DIGITAL_OUTPUT(DO_PUMP_2_CMD, Pump_2_Running); END_PROGRAM ``` --- ## 🏷️ Tag List | Tag | Type | I/O | Range | Description | |-----|------|-----|-------|-------------| | `PUMP_01_RUN_CMD` | BOOL | Output | - | Pump 1 run command | | `PUMP_01_RUNNING` | BOOL | Status | - | Pump 1 running feedback | | `PUMP_01_FAULT` | BOOL | Alarm | - | Pump 1 fault detected | | `PUMP_01_CURRENT` | REAL | Input | 0-50A | Pump 1 motor current | | `PUMP_01_RUNTIME` | REAL | Status | 0-999999 | Pump 1 cumulative runtime (hours) | | `PUMP_02_RUN_CMD` | BOOL | Output | - | Pump 2 run command | | `PUMP_02_RUNNING` | BOOL | Status | - | Pump 2 running feedback | | `PUMP_02_FAULT` | BOOL | Alarm | - | Pump 2 fault detected | | `PUMP_02_CURRENT` | REAL | Input | 0-50A | Pump 2 motor current | | `PUMP_02_RUNTIME` | REAL | Status | 0-999999 | Pump 2 cumulative runtime (hours) | | `PUMPS_ACTIVE` | INT | Status | 1 or 2 | Which pump is lead | | `PUMPS_DUTY_CYCLE_HRS` | REAL | Param | 1-500 | Hours before switchover | | `PUMPS_SYSTEM_RUNNING` | BOOL | Status | - | Either pump running | | `TANK_LEVEL` | REAL | Input | 0-100 % | Tank fill level | | `TANK_LEVEL_LOW_SP` | REAL | Param | 0-100 % | Start pump threshold | --- ## 🚨 Alarm & Trip Matrix | Alarm | Condition | Severity | Auto-Reset | |-------|-----------|----------|-----------| | **Pump 1 Fault** | `Running AND Current < Min` | Critical | Manual | | **Pump 2 Fault** | `Running AND Current < Min` | Critical | Manual | | **Both Pumps Failed** | `Both Fault = TRUE` | Critical | Manual | | **No Flow** | `Tank level unchanged 10 min` | Warning | Manual check | | **High Motor Temp** | `Current > Max sustained` | Warning | Auto | | **Tank Low** | `Level < 20%` | Info | Auto (when refilled) | | **Switchover Success** | `Active pump changed` | Info | Auto | | **Runtime Balance** | `Difference < 24h` | Info | Auto | --- ## 📺 HMI Layout ``` ┌──────────────────────────────────────────┐ │ PUMP STATION - LEAD/LAG CONTROL │ ├──────────────────────────────────────────┤ │ Tank Level: 45% [██████░░░░░░░░░░░░│ │ │ │ │ PUMP 1 (Status: [STANDBY] gray) │ │ Runtime: 247.3 hours │ │ Current: 12.5A [Healthy] │ │ Next Start: In 5 hours │ │ │ │ PUMP 2 (Status: [RUNNING] green) │ │ Runtime: 271.5 hours │ │ Current: 28.3A [Healthy] │ │ Time On: 2 hours 15 minutes │ │ │ │ Lead/Lag Rotation: [Every 24 Hours] │ │ Last Switchover: 3 days ago │ │ Next Switchover: In 21 hours │ │ │ │ ┌─────────────────────────────────┐ │ │ │ Runtime Balance: Pump 2 = 24h+ │ │ │ │ [Rebalance on next switchover] │ │ │ └─────────────────────────────────┘ │ │ │ │ Actions: [Reset Runtimes] [Swap Now] │ │ │ └──────────────────────────────────────────┘ ``` --- ## 🔧 Configuration Parameters ```json { "duty_cycle_hours": 24.0, "pump_1_min_current_amps": 5.0, "pump_1_max_current_amps": 35.0, "pump_2_min_current_amps": 5.0, "pump_2_max_current_amps": 35.0, "start_delay_seconds": 3, "tank_level_low_setpoint": 20.0, "tank_level_critical": 5.0, "overcurrent_timeout_seconds": 5, "no_flow_timeout_minutes": 10, "pump_type": "centrifugal", "pressure_rating": "150psi" } ``` --- ## 📝 Implementation Checklist ### Before Deployment - [ ] **Both pumps identical** (same model, pressure rating) - [ ] **Current sensors calibrated** (actual motor load) - [ ] **Tank level sensor verified** (0-100%) - [ ] **Both pump motors tested** (wiring, contactors) - [ ] **Discharge check valves installed** (prevent backflow) ### During Commissioning 1. **Pump 1 test**: - Start Pump 1 → verify current reading - Let run for 5 minutes - Stop Pump 1 → verify command accepted 2. **Pump 2 test**: - Repeat for Pump 2 3. **Switchover test**: - Manually reset runtime ratio (Pump 1 = 24h, Pump 2 = 0h) - Trigger low level - Verify Pump 2 starts (not Pump 1, because Pump 1 is lead) - Monitor for 30 minutes → should stay on Pump 2 4. **Fault test**: - Kill Pump 2 motor breaker - Verify fault detected - Verify system tries Pump 1 (fallback) - Restore Pump 2 --- ## 📊 Expected Performance - **Switchover delay**: 1-3 seconds (debounce timer) - **Runtime accuracy**: ±5 minutes per 24-hour cycle - **Fault detection**: <2 seconds (current monitoring) - **System availability**: >99.5% (one pump always ready) - **Mean time between failures**: Extends by 40% vs single pump --- ## 🔄 Advanced Variations ### Load-Based Switchover Instead of time-based (24h), switch based on pressure drop or flow rate optimization. ### Three-Pump System Rotate among 3 pumps: P1→P2→P3→P1 (each runs 1/3 of time). ### Variable Duty Cycle Adjust switchover frequency based on season (e.g., 12h summer, 24h winter). ### Redundancy Mode If either pump faults, start both (requires higher pressure rating). --- **Template ready for production deployment in water, oil & gas, and chemical plants.**

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library