Level Alarm And Control — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 38 views

# Level Alarm and Control — Usage Guide ## Overview Four-tier tank alarm scheme with confirmation delays and hysteresis, combined with simple fill and drain pump control. This template is suited to Siemens STEP 7 / TIA style applications where discrete alarms and on/off control are preferred over PID. ## Alarm Hierarchy | Stage | Setpoint | Purpose | |------|----------|---------| | HH | `SP_HH` | Safety / overflow prevention | | H | `SP_H` | Early warning high level | | L | `SP_L` | Early warning low level | | LL | `SP_LL` | Safety / dry-run prevention | Each alarm uses confirmation delay plus reset hysteresis to prevent nuisance alarms from sloshing or transmitter noise. ## Control Strategy - Fill pump starts at `FILL_ON_SP`, stops at `FILL_OFF_SP` - Drain pump starts at `DRAIN_ON_SP`, stops at `DRAIN_OFF_SP` - Fill and drain are mutually interlocked; only one runs at a time - On transmitter failure, both pumps stop fail-safe ## Commissioning 1. Verify 4-20mA scaling from empty to full tank 2. Force each alarm threshold and confirm delay/hysteresis behaviour 3. Test fill pump start/stop thresholds with falling/rising level 4. Test drain pump start/stop thresholds with rising/falling level 5. Disconnect transmitter signal and confirm both pumps stop and `ALM_XMTR_FAIL` activates --- ## Control Logic — Vendor-Agnostic Pseudocode # Level Alarm and Control — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 | STEP 7 / TIA Portal style ## Scan Rate: 100ms | Pattern: LL/L/H/HH 4-tier alarm staging with on/off pump control ``` ROUTINE: LevelAlarmControl SCAN_RATE: 100ms // ═══════════════════════════════════════════════════════════════ // SECTION 1 — LEVEL MEASUREMENT (4-20mA with wire-break detection) // ═══════════════════════════════════════════════════════════════ LT001_MA := SCALE(LT001_RAW, 0, 27648, 4.0, 20.0) LT001_VALID := (LT001_MA >= 3.8) AND (LT001_MA <= 20.5) IF LT001_VALID THEN LT001_PV := SCALE(LT001_MA, 4.0, 20.0, 0.0, 100.0) LT001_LAST_GOOD := LT001_PV XMTR_FAULT := FALSE ELSE LT001_PV := LT001_LAST_GOOD XMTR_FAULT := TRUE SET_ALARM(ALM_XMTR_FAIL, HIGH) // Fail-safe: stop all pumps on transmitter loss FILL_PUMP_CMD := FALSE DRAIN_PUMP_CMD := FALSE END_IF // Rate of change calculation (level delta per 100ms scan) LEVEL_ROC := LT001_PV - LT001_PV_PREV LT001_PV_PREV := LT001_PV // ═══════════════════════════════════════════════════════════════ // SECTION 2 — 4-TIER ALARM STAGE PROCESSING // Each stage uses confirmation timers (dead-time) per ISA-18.2. // Timers reset when condition clears. Latch cleared only after // condition drops below setpoint + hysteresis. // ═══════════════════════════════════════════════════════════════ // --- HIGH-HIGH (Critical / Safety) --- IF LT001_PV >= SP_HH THEN ALM_HH_TMR := ALM_HH_TMR + 1 IF ALM_HH_TMR >= ALM_HH_DELAY THEN ALM_LEVEL_HH := TRUE SET_ALARM(ALM_LEVEL_HH, CRITICAL) END_IF ELSIF LT001_PV < (SP_HH - ALM_HYSTERESIS) THEN ALM_HH_TMR := 0 ALM_LEVEL_HH := FALSE END_IF // --- HIGH (Warning) --- IF LT001_PV >= SP_H AND NOT ALM_LEVEL_HH THEN ALM_H_TMR := ALM_H_TMR + 1 IF ALM_H_TMR >= ALM_H_DELAY THEN ALM_LEVEL_H := TRUE SET_ALARM(ALM_LEVEL_H, HIGH) END_IF ELSIF LT001_PV < (SP_H - ALM_HYSTERESIS) THEN ALM_H_TMR := 0 ALM_LEVEL_H := FALSE END_IF // --- LOW (Warning) --- IF LT001_PV <= SP_L AND NOT ALM_LEVEL_LL THEN ALM_L_TMR := ALM_L_TMR + 1 IF ALM_L_TMR >= ALM_L_DELAY THEN ALM_LEVEL_L := TRUE SET_ALARM(ALM_LEVEL_L, HIGH) END_IF ELSIF LT001_PV > (SP_L + ALM_HYSTERESIS) THEN ALM_L_TMR := 0 ALM_LEVEL_L := FALSE END_IF // --- LOW-LOW (Critical / Safety) --- IF LT001_PV <= SP_LL THEN ALM_LL_TMR := ALM_LL_TMR + 1 IF ALM_LL_TMR >= ALM_LL_DELAY THEN ALM_LEVEL_LL := TRUE SET_ALARM(ALM_LEVEL_LL, CRITICAL) END_IF ELSIF LT001_PV > (SP_LL + ALM_HYSTERESIS) THEN ALM_LL_TMR := 0 ALM_LEVEL_LL := FALSE END_IF // ═══════════════════════════════════════════════════════════════ // SECTION 3 — PUMP CONTROL // FILL pump starts at low demand; stops at high setpoint. // DRAIN pump starts at high demand; stops at low setpoint. // Both pumps interlock: only one active at a time. // ═══════════════════════════════════════════════════════════════ CASE MODE_SELECTOR OF 0: // OFF FILL_PUMP_CMD := FALSE DRAIN_PUMP_CMD := FALSE 1: // MANUAL FILL_PUMP_CMD := MAN_FILL_CMD AND NOT XMTR_FAULT AND NOT ALM_LEVEL_HH DRAIN_PUMP_CMD := MAN_DRAIN_CMD AND NOT XMTR_FAULT AND NOT ALM_LEVEL_LL // Prevent both running simultaneously IF FILL_PUMP_CMD AND DRAIN_PUMP_CMD THEN DRAIN_PUMP_CMD := FALSE END_IF 2: // AUTO // Fill pump: ON below FILL_ON_SP, OFF above FILL_OFF_SP IF LT001_PV <= FILL_ON_SP AND NOT XMTR_FAULT AND NOT ALM_LEVEL_LL AND LT001_VALID THEN FILL_PUMP_CMD := TRUE END_IF IF LT001_PV >= FILL_OFF_SP OR ALM_LEVEL_HH OR XMTR_FAULT THEN FILL_PUMP_CMD := FALSE END_IF // Drain pump: ON above DRAIN_ON_SP, OFF below DRAIN_OFF_SP IF LT001_PV >= DRAIN_ON_SP AND NOT XMTR_FAULT AND NOT ALM_LEVEL_HH AND LT001_VALID THEN DRAIN_PUMP_CMD := TRUE END_IF IF LT001_PV <= DRAIN_OFF_SP OR ALM_LEVEL_LL OR XMTR_FAULT THEN DRAIN_PUMP_CMD := FALSE END_IF // Mutual interlock IF FILL_PUMP_CMD AND DRAIN_PUMP_CMD THEN FILL_PUMP_CMD := FALSE // Drain has priority in conflict END_IF END_CASE // ═══════════════════════════════════════════════════════════════ // SECTION 4 — RAPID CHANGE ALARM // ═══════════════════════════════════════════════════════════════ IF ABS(LEVEL_ROC) > RAPID_CHANGE_THRESHOLD THEN SET_ALARM(ALM_RAPID_CHANGE, MEDIUM) END_IF // ═══════════════════════════════════════════════════════════════ // SECTION 5 — HMI OUTPUTS // ═══════════════════════════════════════════════════════════════ HMI_LEVEL_PV := LT001_PV HMI_LEVEL_ROC := LEVEL_ROC HMI_ALM_HH := ALM_LEVEL_HH HMI_ALM_H := ALM_LEVEL_H HMI_ALM_L := ALM_LEVEL_L HMI_ALM_LL := ALM_LEVEL_LL HMI_FILL_PUMP := FILL_PUMP_CMD HMI_DRAIN_PUMP := DRAIN_PUMP_CMD HMI_MODE := MODE_SELECTOR HMI_XMTR_FAULT := XMTR_FAULT END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address LT001_RAW,Level Transmitter Raw ADC,INT,input,,0,27648,,AI:0:0.0 LT001_MA,Level Transmitter mA,REAL,calculated,mA,3.8,20.5,, LT001_PV,Level Process Value,REAL,calculated,%,0,100,, LT001_VALID,Transmitter Healthy,BOOL,calculated,,,,TRUE, LT001_LAST_GOOD,Last Good Level,REAL,internal,%,0,100,50, LT001_PV_PREV,Previous Level for ROC,REAL,internal,%,0,100,50, XMTR_FAULT,Transmitter Fault Active,BOOL,internal,,,,FALSE, LEVEL_ROC,Level Rate of Change per Scan,REAL,calculated,%/scan,-100,100,0, MODE_SELECTOR,Operating Mode (0=OFF 1=MAN 2=AUTO),INT,input,,0,2,2, MAN_FILL_CMD,Manual Fill Pump Command,BOOL,input,,,,FALSE, MAN_DRAIN_CMD,Manual Drain Pump Command,BOOL,input,,,,FALSE, FILL_PUMP_CMD,Fill Pump Run Command,BOOL,output,,,,FALSE,DO:1:0.0 DRAIN_PUMP_CMD,Drain Pump Run Command,BOOL,output,,,,FALSE,DO:1:0.1 FILL_ON_SP,Fill Pump Start Setpoint,REAL,internal,%,0,100,25, FILL_OFF_SP,Fill Pump Stop Setpoint,REAL,internal,%,0,100,55, DRAIN_ON_SP,Drain Pump Start Setpoint,REAL,internal,%,0,100,75, DRAIN_OFF_SP,Drain Pump Stop Setpoint,REAL,internal,%,0,100,45, SP_LL,Level Low-Low Setpoint,REAL,internal,%,0,100,10, SP_L,Level Low Setpoint,REAL,internal,%,0,100,20, SP_H,Level High Setpoint,REAL,internal,%,0,100,80, SP_HH,Level High-High Setpoint,REAL,internal,%,0,100,90, ALM_HYSTERESIS,Alarm Reset Hysteresis,REAL,internal,%,0,10,2, ALM_HH_TMR,HH Alarm Confirmation Timer,INT,internal,,0,1000,0, ALM_H_TMR,H Alarm Confirmation Timer,INT,internal,,0,1000,0, ALM_L_TMR,L Alarm Confirmation Timer,INT,internal,,0,1000,0, ALM_LL_TMR,LL Alarm Confirmation Timer,INT,internal,,0,1000,0, ALM_HH_DELAY,HH Alarm Delay (100ms ticks),INT,internal,,0,1000,10, ALM_H_DELAY,H Alarm Delay (100ms ticks),INT,internal,,0,1000,30, ALM_L_DELAY,L Alarm Delay (100ms ticks),INT,internal,,0,1000,30, ALM_LL_DELAY,LL Alarm Delay (100ms ticks),INT,internal,,0,1000,10, RAPID_CHANGE_THRESHOLD,Rate-of-Change Alarm Threshold,REAL,internal,%/scan,0,20,2, ALM_LEVEL_HH,Level High-High Alarm Active,BOOL,calculated,,,,FALSE, ALM_LEVEL_H,Level High Alarm Active,BOOL,calculated,,,,FALSE, ALM_LEVEL_L,Level Low Alarm Active,BOOL,calculated,,,,FALSE, ALM_LEVEL_LL,Level Low-Low Alarm Active,BOOL,calculated,,,,FALSE, ALM_XMTR_FAIL,Transmitter Failure Alarm,BOOL,calculated,,,,FALSE, ALM_RAPID_CHANGE,Rapid Level Change Alarm,BOOL,calculated,,,,FALSE, HMI_LEVEL_PV,HMI: Level PV,REAL,output,%,0,100,, HMI_LEVEL_ROC,HMI: Level Rate of Change,REAL,output,%/scan,-100,100,0, HMI_ALM_HH,HMI: HH Alarm,BOOL,output,,,,FALSE, HMI_ALM_H,HMI: H Alarm,BOOL,output,,,,FALSE, HMI_ALM_L,HMI: L Alarm,BOOL,output,,,,FALSE, HMI_ALM_LL,HMI: LL Alarm,BOOL,output,,,,FALSE, HMI_FILL_PUMP,HMI: Fill Pump Status,BOOL,output,,,,FALSE, HMI_DRAIN_PUMP,HMI: Drain Pump Status,BOOL,output,,,,FALSE, HMI_MODE,HMI: Operating Mode,INT,output,,0,2,2, HMI_XMTR_FAULT,HMI: Transmitter Fault,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_LEVEL_HH,LT001_PV >= SP_HH,90%,critical,safety,Immediate high-high alarm. Stop inflow or start emergency drain. Investigate risk of overflow.,1s,No ALM_LEVEL_LL,LT001_PV <= SP_LL,10%,critical,safety,Immediate low-low alarm. Protect pumps from cavitation and check upstream supply.,1s,No ALM_XMTR_FAIL,LT001_VALID = FALSE,wire-break,high,equipment,Transmitter failed. Pumps stopped fail-safe. Check wiring and loop power.,5s,No ALM_LEVEL_H,LT001_PV >= SP_H,80%,high,process,Level high. Drain control should respond. Verify process demand and pump status.,3s,No ALM_LEVEL_L,LT001_PV <= SP_L,20%,high,process,Level low. Fill control should respond. Verify supply and fill pump status.,3s,No ALM_RAPID_CHANGE,ABS(LEVEL_ROC) > RAPID_CHANGE_THRESHOLD,>2%/scan,medium,diagnostic,Unexpected level movement. Check valve leakage, sensor noise, or sudden demand change.,0s,Yes ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library