Elevator Up Down Floors — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 39 views

# Elevator Up Down Floors — Usage Guide ## Overview Simple multi-floor elevator template with floor calls, target selection, and door-closed travel interlock. ## Commissioning 1. Verify floor position source correctness at each landing 2. Confirm door must be closed before travel commands are issued 3. Validate stop and door-open behaviour when the target floor is reached --- ## Control Logic — Vendor-Agnostic Pseudocode # Elevator Up Down Floors — Logic ## Standards: IEC 61131-3 ## Scan Rate: 20ms | Pattern: multi-floor up/down call resolution ``` ROUTINE: ElevatorUpDownFloors SCAN_RATE: 20ms // SECTION 1 — FLOOR TARGETING IF CALL_F1 THEN TARGET_FLOOR := 1 END_IF IF CALL_F2 THEN TARGET_FLOOR := 2 END_IF IF CALL_F3 THEN TARGET_FLOOR := 3 END_IF IF CALL_F4 THEN TARGET_FLOOR := 4 END_IF // SECTION 2 — MOTION IF DOOR_CLOSED AND NOT ESTOP_ACTIVE THEN IF CURRENT_FLOOR < TARGET_FLOOR THEN MOTOR_UP_CMD := TRUE; MOTOR_DOWN_CMD := FALSE END_IF IF CURRENT_FLOOR > TARGET_FLOOR THEN MOTOR_DOWN_CMD := TRUE; MOTOR_UP_CMD := FALSE END_IF IF CURRENT_FLOOR = TARGET_FLOOR THEN MOTOR_UP_CMD := FALSE; MOTOR_DOWN_CMD := FALSE; DOOR_OPEN_CMD := TRUE END_IF END_IF // SECTION 3 — SAFETY IF ESTOP_ACTIVE OR NOT DOOR_CLOSED THEN MOTOR_UP_CMD := FALSE; MOTOR_DOWN_CMD := FALSE END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF // SECTION 4 — HMI HMI_CURRENT_FLOOR := CURRENT_FLOOR HMI_TARGET_FLOOR := TARGET_FLOOR END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address CALL_F1,Floor 1 Call,BOOL,input,,,,FALSE, CALL_F2,Floor 2 Call,BOOL,input,,,,FALSE, CALL_F3,Floor 3 Call,BOOL,input,,,,FALSE, CALL_F4,Floor 4 Call,BOOL,input,,,,FALSE, CURRENT_FLOOR,Current Floor Position,INT,input,,1,4,1, TARGET_FLOOR,Target Floor,INT,internal,,1,4,1, DOOR_CLOSED,Door Closed Interlock,BOOL,input,,,,TRUE,DI:0:0.0 DOOR_OPEN_CMD,Door Open Command,BOOL,output,,,,FALSE,DO:1:0.0 ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.1 MOTOR_UP_CMD,Motor Up Command,BOOL,output,,,,FALSE,DO:1:0.1 MOTOR_DOWN_CMD,Motor Down Command,BOOL,output,,,,FALSE,DO:1:0.2 ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_CURRENT_FLOOR,HMI: Current Floor,INT,output,,1,4,1, HMI_TARGET_FLOOR,HMI: Target Floor,INT,output,,1,4,1, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Elevator travel removed immediately.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library