Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Access Trafficindustrial-automation
Vehicle Entry Exit Tracking — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 39 views
# Vehicle Entry Exit Tracking — Usage Guide
## Overview
Dual-loop occupancy tracking template for lots, compounds, or secure yards. Entry is inhibited when configured capacity is reached.
## Commissioning
1. Confirm loop detector edges count one vehicle only
2. Validate occupancy never goes negative on exit events
3. Set `CAPACITY_SP` to the true physical or regulatory capacity
---
## Control Logic — Vendor-Agnostic Pseudocode
# Vehicle Entry Exit Tracking — Logic
## Standards: IEC 61131-3
## Scan Rate: 20ms | Pattern: dual-loop vehicle counting
```
ROUTINE: VehicleEntryExitTracking
SCAN_RATE: 20ms
// SECTION 1 — EDGE DETECTION
ENTRY_EDGE := ENTRY_LOOP AND NOT ENTRY_LOOP_PREV
EXIT_EDGE := EXIT_LOOP AND NOT EXIT_LOOP_PREV
ENTRY_LOOP_PREV := ENTRY_LOOP
EXIT_LOOP_PREV := EXIT_LOOP
// SECTION 2 — COUNTING
IF ENTRY_EDGE THEN VEHICLE_COUNT := VEHICLE_COUNT + 1; ENTRY_COUNT := ENTRY_COUNT + 1 END_IF
IF EXIT_EDGE AND VEHICLE_COUNT > 0 THEN VEHICLE_COUNT := VEHICLE_COUNT - 1; EXIT_COUNT := EXIT_COUNT + 1 END_IF
// SECTION 3 — GATE COMMANDS
ENTRY_GATE_CMD := ENTRY_REQUEST AND VEHICLE_COUNT < CAPACITY_SP
EXIT_GATE_CMD := EXIT_REQUEST
IF VEHICLE_COUNT >= CAPACITY_SP THEN SET_ALARM(ALM_FULL, HIGH) END_IF
// SECTION 4 — HMI
HMI_OCCUPANCY := VEHICLE_COUNT
HMI_ENTRY_COUNT := ENTRY_COUNT
HMI_EXIT_COUNT := EXIT_COUNT
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
ENTRY_LOOP,Entry Vehicle Loop Detector,BOOL,input,,,,FALSE,DI:0:0.0
EXIT_LOOP,Exit Vehicle Loop Detector,BOOL,input,,,,FALSE,DI:0:0.1
ENTRY_LOOP_PREV,Previous Entry Loop State,BOOL,internal,,,,FALSE,
EXIT_LOOP_PREV,Previous Exit Loop State,BOOL,internal,,,,FALSE,
ENTRY_EDGE,Entry Loop Rising Edge,BOOL,calculated,,,,FALSE,
EXIT_EDGE,Exit Loop Rising Edge,BOOL,calculated,,,,FALSE,
ENTRY_REQUEST,Entry Gate Request,BOOL,input,,,,FALSE,
EXIT_REQUEST,Exit Gate Request,BOOL,input,,,,FALSE,
CAPACITY_SP,Maximum Occupancy,INT,internal,,0,100000,100,
VEHICLE_COUNT,Current Occupancy Count,DINT,internal,,0,100000,0,
ENTRY_COUNT,Total Entries,DINT,internal,,0,999999,0,
EXIT_COUNT,Total Exits,DINT,internal,,0,999999,0,
ENTRY_GATE_CMD,Entry Gate Command,BOOL,output,,,,FALSE,DO:1:0.0
EXIT_GATE_CMD,Exit Gate Command,BOOL,output,,,,FALSE,DO:1:0.1
ALM_FULL,Facility Full Alarm,BOOL,calculated,,,,FALSE,
HMI_OCCUPANCY,HMI: Occupancy Count,DINT,output,,0,100000,0,
HMI_ENTRY_COUNT,HMI: Entry Count,DINT,output,,0,999999,0,
HMI_EXIT_COUNT,HMI: Exit Count,DINT,output,,0,999999,0,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_FULL,VEHICLE_COUNT >= CAPACITY_SP,capacity,high,process,Facility at full capacity. Entry gate held closed until space is available.,0s,No
```