Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Conveyorsindustrial-automation

4 Conveyor Interlock — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 45 views

# 4 Conveyor Interlock — Usage Guide ## Overview Downstream-first conveyor start sequence for four linked conveyors. Each upstream conveyor requires the downstream conveyor to be healthy and running before it can start. Any downstream fault propagates upstream shutdown. ## Sequence 1. Start Conveyor 4 2. After feedback, start Conveyor 3 3. After feedback, start Conveyor 2 4. After feedback, start Conveyor 1 This prevents product pile-up and ensures downstream flow path is available before feeding material. ## Commissioning 1. Verify each conveyor run feedback before enabling auto sequence 2. Test downstream fault propagation from Conveyor 4 backward 3. Test E-stop and confirm all commands drop immediately --- ## Control Logic — Vendor-Agnostic Pseudocode # 4 Conveyor Interlock — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 10ms | Pattern: downstream permissive start sequence with E-stop cascade ``` ROUTINE: FourConveyorInterlock SCAN_RATE: 10ms // SECTION 1 — SAFETY AND PERMISSIVES SYSTEM_READY := NOT ESTOP_ACTIVE AND NOT GLOBAL_FAULT C4_READY := SYSTEM_READY AND C4_HEALTHY C3_READY := C4_READY AND C3_HEALTHY C2_READY := C3_READY AND C2_HEALTHY C1_READY := C2_READY AND C1_HEALTHY // SECTION 2 — START SEQUENCE (downstream to upstream) IF AUTO_START_CMD AND C4_READY THEN C4_CMD := TRUE END_IF IF C4_RUN_FB AND C3_READY THEN C3_START_TMR := C3_START_TMR + 1 IF C3_START_TMR >= START_DELAY_TICKS THEN C3_CMD := TRUE END_IF END_IF IF C3_RUN_FB AND C2_READY THEN C2_START_TMR := C2_START_TMR + 1 IF C2_START_TMR >= START_DELAY_TICKS THEN C2_CMD := TRUE END_IF END_IF IF C2_RUN_FB AND C1_READY THEN C1_START_TMR := C1_START_TMR + 1 IF C1_START_TMR >= START_DELAY_TICKS THEN C1_CMD := TRUE END_IF END_IF // SECTION 3 — STOP CASCADE (upstream to downstream) IF STOP_CMD OR ESTOP_ACTIVE THEN C1_CMD := FALSE C2_CMD := FALSE C3_CMD := FALSE C4_CMD := FALSE END_IF // SECTION 4 — FAULT PROPAGATION IF C4_FAULT THEN C1_CMD := FALSE; C2_CMD := FALSE; C3_CMD := FALSE; SET_ALARM(ALM_C4_FAULT, HIGH) END_IF IF C3_FAULT THEN C1_CMD := FALSE; C2_CMD := FALSE; SET_ALARM(ALM_C3_FAULT, HIGH) END_IF IF C2_FAULT THEN C1_CMD := FALSE; SET_ALARM(ALM_C2_FAULT, HIGH) END_IF IF C1_FAULT THEN SET_ALARM(ALM_C1_FAULT, HIGH) END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF // SECTION 5 — HMI OUTPUTS HMI_C1 := C1_RUN_FB HMI_C2 := C2_RUN_FB HMI_C3 := C3_RUN_FB HMI_C4 := C4_RUN_FB HMI_READY := C1_READY END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address AUTO_START_CMD,Auto Start Command,BOOL,input,,,,FALSE, STOP_CMD,Stop Command,BOOL,input,,,,FALSE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 GLOBAL_FAULT,Global System Fault,BOOL,input,,,,FALSE, START_DELAY_TICKS,Inter-conveyor Start Delay (10ms ticks),INT,internal,,0,1000,100, C1_HEALTHY,Conveyor 1 Healthy,BOOL,input,,,,TRUE,DI:0:0.1 C2_HEALTHY,Conveyor 2 Healthy,BOOL,input,,,,TRUE,DI:0:0.2 C3_HEALTHY,Conveyor 3 Healthy,BOOL,input,,,,TRUE,DI:0:0.3 C4_HEALTHY,Conveyor 4 Healthy,BOOL,input,,,,TRUE,DI:0:0.4 C1_FAULT,Conveyor 1 Fault,BOOL,input,,,,FALSE,DI:0:0.5 C2_FAULT,Conveyor 2 Fault,BOOL,input,,,,FALSE,DI:0:0.6 C3_FAULT,Conveyor 3 Fault,BOOL,input,,,,FALSE,DI:0:0.7 C4_FAULT,Conveyor 4 Fault,BOOL,input,,,,FALSE,DI:0:1.0 C1_RUN_FB,Conveyor 1 Run Feedback,BOOL,input,,,,FALSE,DI:0:1.1 C2_RUN_FB,Conveyor 2 Run Feedback,BOOL,input,,,,FALSE,DI:0:1.2 C3_RUN_FB,Conveyor 3 Run Feedback,BOOL,input,,,,FALSE,DI:0:1.3 C4_RUN_FB,Conveyor 4 Run Feedback,BOOL,input,,,,FALSE,DI:0:1.4 C1_CMD,Conveyor 1 Run Command,BOOL,output,,,,FALSE,DO:1:0.0 C2_CMD,Conveyor 2 Run Command,BOOL,output,,,,FALSE,DO:1:0.1 C3_CMD,Conveyor 3 Run Command,BOOL,output,,,,FALSE,DO:1:0.2 C4_CMD,Conveyor 4 Run Command,BOOL,output,,,,FALSE,DO:1:0.3 C1_READY,Conveyor 1 Permissive Ready,BOOL,calculated,,,,FALSE, C2_READY,Conveyor 2 Permissive Ready,BOOL,calculated,,,,FALSE, C3_READY,Conveyor 3 Permissive Ready,BOOL,calculated,,,,FALSE, C4_READY,Conveyor 4 Permissive Ready,BOOL,calculated,,,,FALSE, C1_START_TMR,Conveyor 1 Start Delay Timer,INT,internal,,0,1000,0, C2_START_TMR,Conveyor 2 Start Delay Timer,INT,internal,,0,1000,0, C3_START_TMR,Conveyor 3 Start Delay Timer,INT,internal,,0,1000,0, ALM_C1_FAULT,Conveyor 1 Fault Alarm,BOOL,calculated,,,,FALSE, ALM_C2_FAULT,Conveyor 2 Fault Alarm,BOOL,calculated,,,,FALSE, ALM_C3_FAULT,Conveyor 3 Fault Alarm,BOOL,calculated,,,,FALSE, ALM_C4_FAULT,Conveyor 4 Fault Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Active Alarm,BOOL,calculated,,,,FALSE, HMI_C1,HMI: Conveyor 1 Status,BOOL,output,,,,FALSE, HMI_C2,HMI: Conveyor 2 Status,BOOL,output,,,,FALSE, HMI_C3,HMI: Conveyor 3 Status,BOOL,output,,,,FALSE, HMI_C4,HMI: Conveyor 4 Status,BOOL,output,,,,FALSE, HMI_READY,HMI: System Ready,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. All conveyors stopped. Investigate before reset.,0s,No ALM_C4_FAULT,C4_FAULT = TRUE,N/A,high,equipment,Downstream conveyor fault. Entire line stopped to prevent pile-up.,0s,No ALM_C3_FAULT,C3_FAULT = TRUE,N/A,high,equipment,Conveyor 3 fault. Upstream conveyors stopped to protect line.,0s,No ALM_C2_FAULT,C2_FAULT = TRUE,N/A,high,equipment,Conveyor 2 fault. Conveyor 1 stopped to prevent accumulation.,0s,No ALM_C1_FAULT,C1_FAULT = TRUE,N/A,medium,equipment,Conveyor 1 fault. Inspect motor and belt condition.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library