Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Sorting Classificationindustrial-automation
Waste Sorting System — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 36 views
# Waste Sorting System — Usage Guide
## Overview
Sensor-array waste sorting template for metal, plastic, glass, and general waste streams.
## Commissioning
1. Validate each sensor technology with representative sample materials
2. Confirm route outputs align with mechanical diverter positions
3. Define plant policy for classifier fault fallback before production use
---
## Control Logic — Vendor-Agnostic Pseudocode
# Waste Sorting System — Logic
## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2
## Scan Rate: 20ms | Pattern: sensor-array classification with route outputs
```
ROUTINE: WasteSortingSystem
SCAN_RATE: 20ms
// SECTION 1 — MATERIAL CLASSIFICATION
IF INSPECTION_DONE THEN
IF METAL_DETECT THEN CLASS := 1
ELSIF NIR_PLASTIC THEN CLASS := 2
ELSIF GLASS_DETECT THEN CLASS := 3
ELSE CLASS := 4
END_IF
END_IF
// SECTION 2 — ROUTING
ROUTE_METAL := (CLASS = 1)
ROUTE_PLASTIC := (CLASS = 2)
ROUTE_GLASS := (CLASS = 3)
ROUTE_GENERAL := (CLASS = 4)
// SECTION 3 — ALARMS
IF SENSOR_FAULT THEN SET_ALARM(ALM_SENSOR_FAULT, HIGH) END_IF
IF AIR_PRESS_LOW THEN SET_ALARM(ALM_AIR_LOW, HIGH) END_IF
// SECTION 4 — HMI
HMI_CLASS := CLASS
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
INSPECTION_DONE,Inspection Complete Pulse,BOOL,input,,,,FALSE,DI:0:0.0
METAL_DETECT,Metal Detection Result,BOOL,input,,,,FALSE,DI:0:0.1
NIR_PLASTIC,NIR Plastic Identification Result,BOOL,input,,,,FALSE,DI:0:0.2
GLASS_DETECT,Glass Identification Result,BOOL,input,,,,FALSE,DI:0:0.3
SENSOR_FAULT,Classifier Sensor Fault,BOOL,input,,,,FALSE,DI:0:0.4
AIR_PRESS_LOW,Air Pressure Low,BOOL,input,,,,FALSE,DI:0:0.5
CLASS,Assigned Waste Class,INT,internal,,0,4,0,
ROUTE_METAL,Metal Route Command,BOOL,output,,,,FALSE,DO:1:0.0
ROUTE_PLASTIC,Plastic Route Command,BOOL,output,,,,FALSE,DO:1:0.1
ROUTE_GLASS,Glass Route Command,BOOL,output,,,,FALSE,DO:1:0.2
ROUTE_GENERAL,General Waste Route Command,BOOL,output,,,,FALSE,DO:1:0.3
ALM_SENSOR_FAULT,Classifier Sensor Fault Alarm,BOOL,calculated,,,,FALSE,
ALM_AIR_LOW,Air Pressure Low Alarm,BOOL,calculated,,,,FALSE,
HMI_CLASS,HMI: Waste Class,INT,output,,0,4,0,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_SENSOR_FAULT,SENSOR_FAULT = TRUE,N/A,high,equipment,Material classification sensors unhealthy. Stop line or divert to general waste by policy.,0s,No
ALM_AIR_LOW,AIR_PRESS_LOW = TRUE,N/A,high,equipment,Insufficient air pressure for ejection devices. Restore air supply before auto mode.,0s,No
```