Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Pump Systemsindustrial-automation

Three Input Permissive Pump — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 44 views

# Three-Input Permissive Pump Logic — Usage Guide ## Overview Implements the industry-standard AND-gate permissive pattern with 3 configurable process permissives plus hardwired E-Stop and overload, a 5-bit diagnostic word for HMI display, and individual alarm messages per unsatisfied condition. Used on: transfer pumps, process feed pumps, any application requiring multiple confirmed conditions before starting. ## Permissive Configuration | Permissive | Default Condition | Configurable? | |-----------|-------------------|--------------| | P1 — Upstream Level | LT_UPSTREAM_PV ≥ 20% | Yes — adjust `UPSTREAM_LEVEL_MIN` | | P2 — Path Clear | Isolation valve open LS active | Swap for any DO/DI condition | | P3 — Downstream Capacity | LT_DOWNSTREAM_PV < 85% | Yes — adjust `DOWNSTREAM_LEVEL_MAX` | | P4 — Overload (hardwired) | NC contact from MCC | Hardwired, not software-adjustable | | P5 — E-Stop (hardwired) | NC safety relay loop | Hardwired, not software-adjustable | ## PERMISSIVE_WORD Bit Map | Bit | Weight | Permissive | |-----|--------|-----------| | 0 | 1 | P1 Upstream Level | | 1 | 2 | P2 Path Clear | | 2 | 4 | P3 Downstream Capacity | | 3 | 8 | P4 Overload OK | | 4 | 16 | P5 E-Stop OK | All 5 = 31 → PERMISSIVES_OK = TRUE ## Adding More Permissives Extend the pattern: add PERM_RAW[3], a new DB_CTR[3], set PERMISSIVE_WORD bit 5, and update the master gate to check bit 5 (PERMISSIVE_WORD = 63 for 6 permissives). ## Commissioning - Force each permissive condition false one at a time; confirm pump cannot start - Verify individual alarm messages appear on HMI for each failure - Check PERMISSIVE_WORD register via HMI — should show which bits are missing - Test discrepancy alarm by disconnecting feedback wire --- ## Control Logic — Vendor-Agnostic Pseudocode # Three-Input Permissive Pump Logic — Logic ## Standards: IEC 61131-3 | ISA-5.1 | IEC 61508 SIL1 ## Scan Rate: 10ms | Pattern: AND-gate permissive with individual diagnostics ``` ROUTINE: ThreeInputPermissivePump SCAN_RATE: 10ms // ═══════════════════════════════════════════════════════════════ // SECTION 1 — INPUT CONDITIONING // Each permissive input is debounced and individually alarmed. // This pattern is used in TIA Portal as a network-per-permissive // style with explicit status bits for HMI display. // ═══════════════════════════════════════════════════════════════ // Debounce all 3 permissive inputs (20ms) FOR i := 0 TO 2 DO IF PERM_RAW[i] THEN DB_CTR[i] := MIN(DB_CTR[i] + 1, 3) ELSE DB_CTR[i] := MAX(DB_CTR[i] - 1, 0) END_IF PERM_DB[i] := (DB_CTR[i] >= 2) END_FOR // ═══════════════════════════════════════════════════════════════ // SECTION 2 — PERMISSIVE CONDITION DEFINITIONS // P1: Upstream vessel has adequate level (min fill before pumping) // P2: Flow path clear (manual isolation valve position confirmed) // P3: Receiving vessel has capacity (not high-high) // ═══════════════════════════════════════════════════════════════ // P1: Upstream level adequate (≥ LOW_LEVEL_SETPOINT) PERM_1_UPSTREAM_LEVEL := (LT_UPSTREAM_PV >= UPSTREAM_LEVEL_MIN) PERM_1_ACTIVE := PERM_DB[0] AND PERM_1_UPSTREAM_LEVEL // P2: Flow path confirmed clear PERM_2_PATH_CLEAR := (XV_ISOLATION_OPEN_LS AND NOT XV_ISOLATION_CLOSED_LS) PERM_2_ACTIVE := PERM_DB[1] AND PERM_2_PATH_CLEAR // P3: Downstream vessel has capacity (level < HH setpoint) PERM_3_DOWNSTREAM_CAP := (LT_DOWNSTREAM_PV < DOWNSTREAM_LEVEL_MAX) PERM_3_ACTIVE := PERM_DB[2] AND PERM_3_DOWNSTREAM_CAP // ═══════════════════════════════════════════════════════════════ // SECTION 3 — MASTER PERMISSIVE GATE // All three permissives AND'ed. Individual failures alarmed. // Provides 8-state diagnostic word for HMI bit-masking. // ═══════════════════════════════════════════════════════════════ PERMISSIVE_WORD := 0 IF PERM_1_ACTIVE THEN PERMISSIVE_WORD := PERMISSIVE_WORD OR 1 END_IF IF PERM_2_ACTIVE THEN PERMISSIVE_WORD := PERMISSIVE_WORD OR 2 END_IF IF PERM_3_ACTIVE THEN PERMISSIVE_WORD := PERMISSIVE_WORD OR 4 END_IF IF PERM_OL_OK THEN PERMISSIVE_WORD := PERMISSIVE_WORD OR 8 END_IF IF PERM_ESTOP_OK THEN PERMISSIVE_WORD := PERMISSIVE_WORD OR 16 END_IF // All 5 conditions required (3 process + OL + E-Stop) PERMISSIVES_OK := (PERMISSIVE_WORD = 31) // 0b11111 // ═══════════════════════════════════════════════════════════════ // SECTION 4 — PUMP CONTROL WITH PERMISSIVE GATE // Start is gated through permissive AND gate. // Any permissive loss during run → latched stop (requires reset). // ═══════════════════════════════════════════════════════════════ CASE MODE_SELECTOR OF 0: PUMP_CMD := FALSE; PUMP_LATCH := FALSE 1: // MANUAL IF PB_START AND PERMISSIVES_OK THEN PUMP_LATCH := TRUE END_IF IF PB_STOP OR NOT PERMISSIVES_OK THEN PUMP_LATCH := FALSE END_IF PUMP_CMD := PUMP_LATCH 2: // AUTO IF AUTO_START AND PERMISSIVES_OK THEN PUMP_LATCH := TRUE END_IF IF AUTO_STOP OR PB_STOP OR NOT PERMISSIVES_OK THEN PUMP_LATCH := FALSE END_IF PUMP_CMD := PUMP_LATCH END_CASE // ═══════════════════════════════════════════════════════════════ // SECTION 5 — PERMISSIVE FAILURE DIAGNOSTICS // Individual alarms for each unsatisfied permissive. // HMI word enables single-screen diagnosis. // ═══════════════════════════════════════════════════════════════ IF NOT PERM_1_ACTIVE THEN SET_ALARM(ALM_PERM1_FAIL, MEDIUM, MSG="Upstream level too low — min level not reached") END_IF IF NOT PERM_2_ACTIVE THEN SET_ALARM(ALM_PERM2_FAIL, MEDIUM, MSG="Flow path not clear — check isolation valve XV") END_IF IF NOT PERM_3_ACTIVE THEN SET_ALARM(ALM_PERM3_FAIL, MEDIUM, MSG="Downstream vessel full — no capacity for transfer") END_IF IF NOT PERM_OL_OK THEN SET_ALARM(ALM_OVERLOAD, HIGH, MSG="Motor overload relay tripped") END_IF IF NOT PERM_ESTOP_OK THEN SET_ALARM(ALM_ESTOP, CRITICAL, MSG="E-Stop active — check safety circuit") END_IF // Discrepancy check IF PUMP_CMD <> PUMP_RUN_FB THEN DISC_TMR := DISC_TMR + 1 IF DISC_TMR >= 300 THEN SET_ALARM(ALM_DISCREPANCY, MEDIUM) END_IF ELSE DISC_TMR := 0 END_IF // ═══════════════════════════════════════════════════════════════ // SECTION 6 — HMI OUTPUTS // ═══════════════════════════════════════════════════════════════ HMI_PERMISSIVE_WORD := PERMISSIVE_WORD HMI_PERMISSIVES_OK := PERMISSIVES_OK HMI_PUMP_RUNNING := PUMP_RUN_FB HMI_PUMP_CMD := PUMP_CMD HMI_PERM1_STATE := PERM_1_ACTIVE HMI_PERM2_STATE := PERM_2_ACTIVE HMI_PERM3_STATE := PERM_3_ACTIVE HMI_UPSTREAM_LEVEL := LT_UPSTREAM_PV HMI_DOWNSTREAM_LEVEL := LT_DOWNSTREAM_PV HMI_MODE := MODE_SELECTOR END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address PERM_RAW_0,Permissive 1 Raw Input,BOOL,input,,,,FALSE,DI:0:0.0 PERM_RAW_1,Permissive 2 Raw Input,BOOL,input,,,,FALSE,DI:0:0.1 PERM_RAW_2,Permissive 3 Raw Input,BOOL,input,,,,FALSE,DI:0:0.2 DB_CTR_0,Permissive 1 Debounce Counter,INT,internal,,0,3,0, DB_CTR_1,Permissive 2 Debounce Counter,INT,internal,,0,3,0, DB_CTR_2,Permissive 3 Debounce Counter,INT,internal,,0,3,0, PERM_DB_0,Permissive 1 Debounced State,BOOL,calculated,,,,FALSE, PERM_DB_1,Permissive 2 Debounced State,BOOL,calculated,,,,FALSE, PERM_DB_2,Permissive 3 Debounced State,BOOL,calculated,,,,FALSE, LT_UPSTREAM_PV,Upstream Vessel Level,REAL,input,%,0,100,,AI:2:0.0 LT_DOWNSTREAM_PV,Downstream Vessel Level,REAL,input,%,0,100,,AI:2:0.1 XV_ISOLATION_OPEN_LS,Isolation Valve Open Limit Switch,BOOL,input,,,,FALSE,DI:0:0.3 XV_ISOLATION_CLOSED_LS,Isolation Valve Closed Limit Switch,BOOL,input,,,,FALSE,DI:0:0.4 UPSTREAM_LEVEL_MIN,Upstream Level Minimum Permissive,REAL,internal,%,0,100,20, DOWNSTREAM_LEVEL_MAX,Downstream Level Maximum Permissive,REAL,internal,%,0,100,85, PERM_1_UPSTREAM_LEVEL,P1: Upstream Level Condition Met,BOOL,calculated,,,,FALSE, PERM_1_ACTIVE,P1: Permissive 1 Satisfied (debounced),BOOL,calculated,,,,FALSE, PERM_2_PATH_CLEAR,P2: Flow Path Clear Condition,BOOL,calculated,,,,FALSE, PERM_2_ACTIVE,P2: Permissive 2 Satisfied (debounced),BOOL,calculated,,,,FALSE, PERM_3_DOWNSTREAM_CAP,P3: Downstream Capacity Condition,BOOL,calculated,,,,FALSE, PERM_3_ACTIVE,P3: Permissive 3 Satisfied (debounced),BOOL,calculated,,,,FALSE, PERM_OL_OK,Motor Overload Relay Healthy (NC),BOOL,input,,,,TRUE,DI:0:0.5 PERM_ESTOP_OK,E-Stop Circuit Healthy (NC),BOOL,input,,,,TRUE,DI:0:0.6 PERMISSIVE_WORD,Permissive Status Bitmask (5-bit),INT,calculated,,0,31,0, PERMISSIVES_OK,All Permissives Satisfied (PERMISSIVE_WORD=31),BOOL,calculated,,,,FALSE, MODE_SELECTOR,Operating Mode (0=OFF 1=MAN 2=AUTO),INT,input,,0,2,1, PB_START,Start Pushbutton,BOOL,input,,,,FALSE,DI:0:0.7 PB_STOP,Stop Pushbutton (debounced NC),BOOL,input,,,,FALSE,DI:0:0.8 AUTO_START,Auto Start Command from Process,BOOL,input,,,,FALSE, AUTO_STOP,Auto Stop Command from Process,BOOL,input,,,,FALSE, PUMP_CMD,Pump Command Output,BOOL,output,,,,FALSE,DO:1:0.0 PUMP_RUN_FB,Pump Running Feedback,BOOL,input,,,,FALSE,DI:0:0.9 PUMP_LATCH,Pump Latch (Seal-In),BOOL,internal,,,,FALSE, DISC_TMR,Command/Feedback Discrepancy Timer,INT,internal,,0,500,0, ALM_PERM1_FAIL,Permissive 1 Not Satisfied — Upstream Level,BOOL,calculated,,,,FALSE, ALM_PERM2_FAIL,Permissive 2 Not Satisfied — Path Not Clear,BOOL,calculated,,,,FALSE, ALM_PERM3_FAIL,Permissive 3 Not Satisfied — Downstream Full,BOOL,calculated,,,,FALSE, ALM_OVERLOAD,Motor Overload Relay Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Active Alarm,BOOL,calculated,,,,FALSE, ALM_DISCREPANCY,Command/Feedback Discrepancy Alarm,BOOL,calculated,,,,FALSE, HMI_PERMISSIVE_WORD,HMI: Permissive Status Word,INT,output,,0,31,0, HMI_PERMISSIVES_OK,HMI: All Permissives OK Flag,BOOL,output,,,,FALSE, HMI_PUMP_RUNNING,HMI: Pump Running State,BOOL,output,,,,FALSE, HMI_PUMP_CMD,HMI: Pump Command State,BOOL,output,,,,FALSE, HMI_PERM1_STATE,HMI: Permissive 1 State,BOOL,output,,,,FALSE, HMI_PERM2_STATE,HMI: Permissive 2 State,BOOL,output,,,,FALSE, HMI_PERM3_STATE,HMI: Permissive 3 State,BOOL,output,,,,FALSE, HMI_UPSTREAM_LEVEL,HMI: Upstream Level Display,REAL,output,%,0,100,, HMI_DOWNSTREAM_LEVEL,HMI: Downstream Level Display,REAL,output,%,0,100,, HMI_MODE,HMI: Operating Mode,INT,output,,0,2,1, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,PERM_ESTOP_OK = FALSE,N/A,critical,safety,E-Stop activated. Verify safety of area before clearing. Check safety relay wiring.,0s,No ALM_OVERLOAD,PERM_OL_OK = FALSE,N/A,high,equipment,Motor thermal overload. Allow cooling before reset. Investigate overload cause.,0s,No ALM_PERM1_FAIL,PERM_1_ACTIVE = FALSE,20%,medium,process,Upstream level below minimum. Refill upstream vessel or reduce setpoint.,2s,Yes ALM_PERM2_FAIL,PERM_2_ACTIVE = FALSE,N/A,medium,process,Isolation valve not confirmed open or valve discrepancy. Check valve and limit switches.,2s,Yes ALM_PERM3_FAIL,PERM_3_ACTIVE = FALSE,85%,medium,process,Downstream vessel at capacity. Reduce downstream demand or increase HH setpoint.,2s,Yes ALM_DISCREPANCY,PUMP_CMD != PUMP_RUN_FB for >3s,3s,medium,equipment,Output commanded but motor feedback disagrees. Check MCC, contactor, and wiring.,3s,Yes ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library