Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Vision Qualityindustrial-automation
Bottle Quality Inspection — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 35 views
# Bottle Quality Inspection — Usage Guide
## Overview
Vision inspection template for bottled product quality including cap, label, and fill-height checks with reject handling.
## Commissioning
1. Validate each vision result against known good and bad samples
2. Verify reject timing and station offset at production speed
3. Set failure-rate alarm threshold to catch equipment drift without nuisance trips
---
## Control Logic — Vendor-Agnostic Pseudocode
# Bottle Quality Inspection — Logic
## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2
## Scan Rate: 20ms | Pattern: cap, label, fill-height inspection with reject
```
ROUTINE: BottleQualityInspection
SCAN_RATE: 20ms
IF INSPECTION_DONE THEN
QUALITY_OK := CAP_OK AND LABEL_OK AND FILL_OK
IF QUALITY_OK THEN PASS_COUNT := PASS_COUNT + 1 ELSE FAIL_COUNT := FAIL_COUNT + 1; REJECT_CMD := TRUE END_IF
END_IF
IF REJECT_CMD THEN
REJECT_TMR := REJECT_TMR + 1
IF REJECT_TMR >= REJECT_TIME_TICKS THEN REJECT_CMD := FALSE; REJECT_TMR := 0 END_IF
END_IF
IF CAMERA_FAULT THEN SET_ALARM(ALM_CAMERA_FAULT, HIGH) END_IF
IF FAIL_COUNT > 0 AND ((FAIL_COUNT * 100.0) / (PASS_COUNT + FAIL_COUNT)) >= FAIL_RATE_SP THEN SET_ALARM(ALM_FAIL_RATE, HIGH) END_IF
HMI_QUALITY_OK := QUALITY_OK
HMI_PASS_COUNT := PASS_COUNT
HMI_FAIL_COUNT := FAIL_COUNT
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
INSPECTION_DONE,Vision Inspection Complete Pulse,BOOL,input,,,,FALSE,DI:0:0.0
CAP_OK,Cap Present and Correct,BOOL,input,,,,FALSE,
LABEL_OK,Label Present and Correct,BOOL,input,,,,FALSE,
FILL_OK,Fill Height Acceptable,BOOL,input,,,,FALSE,
CAMERA_FAULT,Camera or Vision Fault,BOOL,input,,,,FALSE,DI:0:0.1
QUALITY_OK,Overall Quality Accept,BOOL,calculated,,,,FALSE,
REJECT_CMD,Reject Gate Command,BOOL,output,,,,FALSE,DO:1:0.0
REJECT_TMR,Reject Timer,INT,internal,,0,1000,0,
REJECT_TIME_TICKS,Reject Pulse Duration,INT,internal,,0,1000,25,
PASS_COUNT,Accepted Bottle Count,DINT,internal,,0,999999,0,
FAIL_COUNT,Rejected Bottle Count,DINT,internal,,0,999999,0,
FAIL_RATE_SP,Failure Rate Alarm Threshold,REAL,internal,%,0,100,5,
ALM_CAMERA_FAULT,Vision Camera Fault Alarm,BOOL,calculated,,,,FALSE,
ALM_FAIL_RATE,High Inspection Failure Rate Alarm,BOOL,calculated,,,,FALSE,
HMI_QUALITY_OK,HMI: Quality OK,BOOL,output,,,,FALSE,
HMI_PASS_COUNT,HMI: Pass Count,DINT,output,,0,999999,0,
HMI_FAIL_COUNT,HMI: Fail Count,DINT,output,,0,999999,0,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_CAMERA_FAULT,CAMERA_FAULT = TRUE,N/A,high,equipment,Vision inspection unavailable. Stop line or divert all product per plant policy.,0s,No
ALM_FAIL_RATE,Inspection failure rate >= FAIL_RATE_SP,5%,high,process,Quality failures elevated. Investigate capper, labeler, and filler settings.,0s,No
```