Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Vision Qualityindustrial-automation

Bottle Quality Inspection — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 35 views

# Bottle Quality Inspection — Usage Guide ## Overview Vision inspection template for bottled product quality including cap, label, and fill-height checks with reject handling. ## Commissioning 1. Validate each vision result against known good and bad samples 2. Verify reject timing and station offset at production speed 3. Set failure-rate alarm threshold to catch equipment drift without nuisance trips --- ## Control Logic — Vendor-Agnostic Pseudocode # Bottle Quality Inspection — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 20ms | Pattern: cap, label, fill-height inspection with reject ``` ROUTINE: BottleQualityInspection SCAN_RATE: 20ms IF INSPECTION_DONE THEN QUALITY_OK := CAP_OK AND LABEL_OK AND FILL_OK IF QUALITY_OK THEN PASS_COUNT := PASS_COUNT + 1 ELSE FAIL_COUNT := FAIL_COUNT + 1; REJECT_CMD := TRUE END_IF END_IF IF REJECT_CMD THEN REJECT_TMR := REJECT_TMR + 1 IF REJECT_TMR >= REJECT_TIME_TICKS THEN REJECT_CMD := FALSE; REJECT_TMR := 0 END_IF END_IF IF CAMERA_FAULT THEN SET_ALARM(ALM_CAMERA_FAULT, HIGH) END_IF IF FAIL_COUNT > 0 AND ((FAIL_COUNT * 100.0) / (PASS_COUNT + FAIL_COUNT)) >= FAIL_RATE_SP THEN SET_ALARM(ALM_FAIL_RATE, HIGH) END_IF HMI_QUALITY_OK := QUALITY_OK HMI_PASS_COUNT := PASS_COUNT HMI_FAIL_COUNT := FAIL_COUNT END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address INSPECTION_DONE,Vision Inspection Complete Pulse,BOOL,input,,,,FALSE,DI:0:0.0 CAP_OK,Cap Present and Correct,BOOL,input,,,,FALSE, LABEL_OK,Label Present and Correct,BOOL,input,,,,FALSE, FILL_OK,Fill Height Acceptable,BOOL,input,,,,FALSE, CAMERA_FAULT,Camera or Vision Fault,BOOL,input,,,,FALSE,DI:0:0.1 QUALITY_OK,Overall Quality Accept,BOOL,calculated,,,,FALSE, REJECT_CMD,Reject Gate Command,BOOL,output,,,,FALSE,DO:1:0.0 REJECT_TMR,Reject Timer,INT,internal,,0,1000,0, REJECT_TIME_TICKS,Reject Pulse Duration,INT,internal,,0,1000,25, PASS_COUNT,Accepted Bottle Count,DINT,internal,,0,999999,0, FAIL_COUNT,Rejected Bottle Count,DINT,internal,,0,999999,0, FAIL_RATE_SP,Failure Rate Alarm Threshold,REAL,internal,%,0,100,5, ALM_CAMERA_FAULT,Vision Camera Fault Alarm,BOOL,calculated,,,,FALSE, ALM_FAIL_RATE,High Inspection Failure Rate Alarm,BOOL,calculated,,,,FALSE, HMI_QUALITY_OK,HMI: Quality OK,BOOL,output,,,,FALSE, HMI_PASS_COUNT,HMI: Pass Count,DINT,output,,0,999999,0, HMI_FAIL_COUNT,HMI: Fail Count,DINT,output,,0,999999,0, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_CAMERA_FAULT,CAMERA_FAULT = TRUE,N/A,high,equipment,Vision inspection unavailable. Stop line or divert all product per plant policy.,0s,No ALM_FAIL_RATE,Inspection failure rate >= FAIL_RATE_SP,5%,high,process,Quality failures elevated. Investigate capper, labeler, and filler settings.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library