Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Access Trafficindustrial-automation
Traffic Signal Push Button — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 38 views
# Traffic Signal Push Button — Usage Guide
## Overview
Fixed-time crossing signal with default vehicle green and latched pedestrian call. A pedestrian request is served only after the minimum vehicle green has elapsed.
## Commissioning
1. Validate lamp outputs and flash behaviour
2. Set timing constants to local traffic standard or site safety study
3. Confirm pedestrian calls are latched and not missed during vehicle green
---
## Control Logic — Vendor-Agnostic Pseudocode
# Traffic Signal Push Button — Logic
## Standards: IEC 61131-3 | MUTCD-inspired timing
## Scan Rate: 100ms | Pattern: vehicle green default with pedestrian call
```
ROUTINE: TrafficSignalPushButton
SCAN_RATE: 100ms
// SECTION 1 — PEDESTRIAN CALL LATCH
IF PB_PED THEN PED_CALL := TRUE END_IF
// SECTION 2 — SIGNAL STATE MACHINE
CASE STATE OF
0: // VEHICLE GREEN / PED RED
VEH_GREEN := TRUE; VEH_YELLOW := FALSE; VEH_RED := FALSE; PED_WALK := FALSE
IF PED_CALL THEN TIMER := TIMER + 1; IF TIMER >= MIN_GREEN_TICKS THEN STATE := 1; TIMER := 0 END_IF END_IF
1: // VEHICLE YELLOW
VEH_GREEN := FALSE; VEH_YELLOW := TRUE; VEH_RED := FALSE
TIMER := TIMER + 1; IF TIMER >= YELLOW_TICKS THEN STATE := 2; TIMER := 0 END_IF
2: // ALL RED / PED WALK
VEH_RED := TRUE; PED_WALK := TRUE
TIMER := TIMER + 1; IF TIMER >= WALK_TICKS THEN STATE := 3; TIMER := 0 END_IF
3: // PED FLASH / ALL RED
PED_FLASH := TRUE; VEH_RED := TRUE
TIMER := TIMER + 1; IF TIMER >= FLASH_TICKS THEN STATE := 0; TIMER := 0; PED_CALL := FALSE; PED_FLASH := FALSE END_IF
END_CASE
// SECTION 3 — HMI
HMI_STATE := STATE
HMI_PED_CALL := PED_CALL
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
PB_PED,Pedestrian Push Button,BOOL,input,,,,FALSE,DI:0:0.0
PED_CALL,Pedestrian Call Latched,BOOL,internal,,,,FALSE,
STATE,Signal State,INT,internal,,0,3,0,
TIMER,State Timer,INT,internal,,0,10000,0,
MIN_GREEN_TICKS,Minimum Vehicle Green Time,INT,internal,,0,10000,100,
YELLOW_TICKS,Vehicle Yellow Time,INT,internal,,0,10000,30,
WALK_TICKS,Pedestrian Walk Time,INT,internal,,0,10000,80,
FLASH_TICKS,Pedestrian Flash Time,INT,internal,,0,10000,50,
VEH_GREEN,Vehicle Green Output,BOOL,output,,,,FALSE,DO:1:0.0
VEH_YELLOW,Vehicle Yellow Output,BOOL,output,,,,FALSE,DO:1:0.1
VEH_RED,Vehicle Red Output,BOOL,output,,,,FALSE,DO:1:0.2
PED_WALK,Pedestrian Walk Output,BOOL,output,,,,FALSE,DO:1:0.3
PED_FLASH,Pedestrian Flash Output,BOOL,output,,,,FALSE,DO:1:0.4
HMI_STATE,HMI: Signal State,INT,output,,0,3,0,
HMI_PED_CALL,HMI: Pedestrian Call,BOOL,output,,,,FALSE,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_NONE,No active alarms defined for fixed-time signal template,N/A,low,diagnostic,Add lamp failure monitoring where required by site standard.,0s,Yes
```