Paper Cutter Encoder — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 32 views
# Paper Cutter Encoder — Usage Guide
## Overview
Length-based paper cutting using encoder pulses to trigger the knife at precise intervals. Suitable for web handling, sheet cutting, and continuous product segmentation.
## Commissioning
1. Calibrate `MM_PER_PULSE` from roller circumference and encoder resolution
2. Verify cut repeatability at low and nominal line speed
3. Confirm knife timeout alarm catches missed return-home feedback
---
## Control Logic — Vendor-Agnostic Pseudocode
# Paper Cutter Encoder — Logic
## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2
## Scan Rate: 5ms | Pattern: encoder pulse length measurement with knife trigger
```
ROUTINE: PaperCutterEncoder
SCAN_RATE: 5ms
// SECTION 1 — ENCODER COUNTING
ENC_EDGE := ENC_A AND NOT ENC_A_PREV
ENC_A_PREV := ENC_A
IF ENC_EDGE THEN ENCODER_COUNT := ENCODER_COUNT + 1 END_IF
LENGTH_MM := ENCODER_COUNT * MM_PER_PULSE
// SECTION 2 — KNIFE TRIGGER
IF AUTO_MODE AND LENGTH_MM >= CUT_LENGTH_SP AND NOT KNIFE_BUSY THEN
KNIFE_CMD := TRUE
KNIFE_BUSY := TRUE
CUT_COUNT := CUT_COUNT + 1
ENCODER_COUNT := 0
END_IF
IF KNIFE_BUSY THEN
KNIFE_TMR := KNIFE_TMR + 1
IF KNIFE_TMR >= KNIFE_PULSE_TICKS THEN
KNIFE_CMD := FALSE
END_IF
IF KNIFE_HOME_FB THEN
KNIFE_BUSY := FALSE
KNIFE_TMR := 0
END_IF
END_IF
// SECTION 3 — ALARMS
IF NOT KNIFE_HOME_FB AND KNIFE_TMR >= KNIFE_TIMEOUT_TICKS THEN
SET_ALARM(ALM_KNIFE_TIMEOUT, HIGH)
END_IF
IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF
// SECTION 4 — HMI OUTPUTS
HMI_LENGTH_MM := LENGTH_MM
HMI_CUT_COUNT := CUT_COUNT
HMI_KNIFE_BUSY := KNIFE_BUSY
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE,
ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0
ENC_A,Encoder A Pulse Input,BOOL,input,,,,FALSE,DI:0:0.1
ENC_A_PREV,Previous Encoder A State,BOOL,internal,,,,FALSE,
ENC_EDGE,Encoder Rising Edge,BOOL,calculated,,,,FALSE,
ENCODER_COUNT,Encoder Pulse Count,DINT,internal,,0,999999,0,
MM_PER_PULSE,Linear Travel per Pulse,REAL,internal,mm,0,100,0.5,
LENGTH_MM,Measured Length,REAL,calculated,mm,0,999999,0,
CUT_LENGTH_SP,Cut Length Setpoint,REAL,input,mm,0,999999,500,
KNIFE_CMD,Knife Solenoid Command,BOOL,output,,,,FALSE,DO:1:0.0
KNIFE_HOME_FB,Knife Home Feedback,BOOL,input,,,,TRUE,DI:0:0.2
KNIFE_BUSY,Knife Cycle In Progress,BOOL,internal,,,,FALSE,
KNIFE_TMR,Knife Pulse/Timeout Timer,INT,internal,,0,10000,0,
KNIFE_PULSE_TICKS,Knife Command Pulse Width (5ms ticks),INT,internal,,0,1000,20,
KNIFE_TIMEOUT_TICKS,Knife Cycle Timeout (5ms ticks),INT,internal,,0,10000,400,
CUT_COUNT,Total Cuts,DINT,internal,,0,999999,0,
ALM_KNIFE_TIMEOUT,Knife Did Not Return Home,BOOL,calculated,,,,FALSE,
ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE,
HMI_LENGTH_MM,HMI: Current Measured Length,REAL,output,mm,0,999999,0,
HMI_CUT_COUNT,HMI: Total Cut Count,DINT,output,,0,999999,0,
HMI_KNIFE_BUSY,HMI: Knife Busy,BOOL,output,,,,FALSE,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Knife motion inhibited immediately.,0s,No
ALM_KNIFE_TIMEOUT,KNIFE_HOME_FB = FALSE for > KNIFE_TIMEOUT_TICKS,2s,high,equipment,Knife did not return home. Stop machine and inspect mechanism.,0s,No
```