Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Conveyorsindustrial-automation

Paper Cutter Encoder — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 32 views

# Paper Cutter Encoder — Usage Guide ## Overview Length-based paper cutting using encoder pulses to trigger the knife at precise intervals. Suitable for web handling, sheet cutting, and continuous product segmentation. ## Commissioning 1. Calibrate `MM_PER_PULSE` from roller circumference and encoder resolution 2. Verify cut repeatability at low and nominal line speed 3. Confirm knife timeout alarm catches missed return-home feedback --- ## Control Logic — Vendor-Agnostic Pseudocode # Paper Cutter Encoder — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 5ms | Pattern: encoder pulse length measurement with knife trigger ``` ROUTINE: PaperCutterEncoder SCAN_RATE: 5ms // SECTION 1 — ENCODER COUNTING ENC_EDGE := ENC_A AND NOT ENC_A_PREV ENC_A_PREV := ENC_A IF ENC_EDGE THEN ENCODER_COUNT := ENCODER_COUNT + 1 END_IF LENGTH_MM := ENCODER_COUNT * MM_PER_PULSE // SECTION 2 — KNIFE TRIGGER IF AUTO_MODE AND LENGTH_MM >= CUT_LENGTH_SP AND NOT KNIFE_BUSY THEN KNIFE_CMD := TRUE KNIFE_BUSY := TRUE CUT_COUNT := CUT_COUNT + 1 ENCODER_COUNT := 0 END_IF IF KNIFE_BUSY THEN KNIFE_TMR := KNIFE_TMR + 1 IF KNIFE_TMR >= KNIFE_PULSE_TICKS THEN KNIFE_CMD := FALSE END_IF IF KNIFE_HOME_FB THEN KNIFE_BUSY := FALSE KNIFE_TMR := 0 END_IF END_IF // SECTION 3 — ALARMS IF NOT KNIFE_HOME_FB AND KNIFE_TMR >= KNIFE_TIMEOUT_TICKS THEN SET_ALARM(ALM_KNIFE_TIMEOUT, HIGH) END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF // SECTION 4 — HMI OUTPUTS HMI_LENGTH_MM := LENGTH_MM HMI_CUT_COUNT := CUT_COUNT HMI_KNIFE_BUSY := KNIFE_BUSY END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 ENC_A,Encoder A Pulse Input,BOOL,input,,,,FALSE,DI:0:0.1 ENC_A_PREV,Previous Encoder A State,BOOL,internal,,,,FALSE, ENC_EDGE,Encoder Rising Edge,BOOL,calculated,,,,FALSE, ENCODER_COUNT,Encoder Pulse Count,DINT,internal,,0,999999,0, MM_PER_PULSE,Linear Travel per Pulse,REAL,internal,mm,0,100,0.5, LENGTH_MM,Measured Length,REAL,calculated,mm,0,999999,0, CUT_LENGTH_SP,Cut Length Setpoint,REAL,input,mm,0,999999,500, KNIFE_CMD,Knife Solenoid Command,BOOL,output,,,,FALSE,DO:1:0.0 KNIFE_HOME_FB,Knife Home Feedback,BOOL,input,,,,TRUE,DI:0:0.2 KNIFE_BUSY,Knife Cycle In Progress,BOOL,internal,,,,FALSE, KNIFE_TMR,Knife Pulse/Timeout Timer,INT,internal,,0,10000,0, KNIFE_PULSE_TICKS,Knife Command Pulse Width (5ms ticks),INT,internal,,0,1000,20, KNIFE_TIMEOUT_TICKS,Knife Cycle Timeout (5ms ticks),INT,internal,,0,10000,400, CUT_COUNT,Total Cuts,DINT,internal,,0,999999,0, ALM_KNIFE_TIMEOUT,Knife Did Not Return Home,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_LENGTH_MM,HMI: Current Measured Length,REAL,output,mm,0,999999,0, HMI_CUT_COUNT,HMI: Total Cut Count,DINT,output,,0,999999,0, HMI_KNIFE_BUSY,HMI: Knife Busy,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Knife motion inhibited immediately.,0s,No ALM_KNIFE_TIMEOUT,KNIFE_HOME_FB = FALSE for > KNIFE_TIMEOUT_TICKS,2s,high,equipment,Knife did not return home. Stop machine and inspect mechanism.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library