Importing & Creating Tags — Engineering Guide

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 44 views

# Importing & Creating Tags Tags are the bridge between physical field signals and TSIMEREZIVO logic, HMI displays, and historical data. This guide covers all three import methods: CSV batch upload, Studio 5000 L5X export, and manual tag creation one-at-a-time. 15 min ## What is a Tag? A tag is a named process variable — a single data point from a PLC, DCS or sensor. Tags have a name, a data type, a PLC address, engineering units, and optionally alarm limits. Every value you see in an HMI display, trend chart, or alarm list is driven by a tag. ### Step 2 — Upload the CSV Go to **Tags → Import → Upload CSV**. Drag and drop your completed CSV file or click Browse. TSIMEREZIVO validates every row and shows a preview table with any errors highlighted in red before committing. ### Step 3 — Review the Validation Report TSIMEREZIVO shows a pre-import report: total rows, valid rows, error rows. Common errors: duplicate tag names, unknown data_type, missing required columns, invalid PLC address format. Fix errors in Excel and re-upload — or fix individual rows in the preview table directly. ### Step 4 — Confirm Import Click **Import Tags**. Tags are created instantly. A success toast shows the count: e.g. *✓ 246 tags imported*. ## Method 2 — Studio 5000 L5X Export If you use Allen-Bradley Studio 5000 or Logix Designer, you can export your entire controller tag database as a standard L5X (XML) file and import it directly into TSIMEREZIVO. ### Step 1 — Export from Studio 5000 In Studio 5000: **File → Save As → Logix Designer XML (.L5X)**. Include Controller Tags and Program Tags. Save the file. ### Step 2 — Upload the L5X In TSIMEREZIVO: **Tags → Import → Upload L5X**. TSIMEREZIVO parses the XML, extracts all controller-scope and program-scope tags, their data types (including User-Defined Types / UDTs), and maps addresses automatically. > **UDT / AOI Member Tags** — TSIMEREZIVO expands UDT members into individual dot-notation tags. E.g. a `MOTOR_FB` UDT becomes `PP101.Speed`, ` PP101.Current`, ` PP101.Fault` etc. AOI tags are similarly expanded. ## Method 3 — Manual Tag Creation ### Step 1 — Go to Tags → New Tag Navigate to **Tags → + New Tag**. Fill in the tag form fields as described in the CSV column definitions above. Use manual entry for individual tags when making a small change or adding tags post-commissioning. ### Step 2 — Assign to Equipment Every tag should be linked to an Equipment record. Use the **Equipment** dropdown to associate this tag with a pump, valve, transmitter, or motor. This enables equipment-level dashboards and tag grouping in HMI faceplates. ## PLC Data Types Reference | type | bits | range | use | |---|---|---|---| | BOOL | 1 | 0 or 1 | Coils, discrete I/O, flags, alarms, push-buttons | | INT | 16 | -32,768 to 32,767 | Raw ADC counts, speed setpoints, counters | | DINT | 32 | -2,147,483,648 to 2,147,483,647 | High-resolution counters, time stamps in ms | | REAL | 32 | ±3.4×10³⁸ (IEEE 754 float) | Scaled process values: temperature, flow, pressure | | LREAL | 64 | ±1.8×10³⁰⁸ (double precision) | High-precision measurement, gas chromatographs | | STRING | var | Up to 82 chars (AB), 254 (S7) | Batch IDs, recipe names, operator messages | | WORD | 16 | 0 to 65,535 | Packed boolean words, status bytes, bitfield registers | | DWORD | 32 | 0 to 4,294,967,295 | 32-bit status, packed alarms, Modbus 32-bit integers | ## Bulk Editing Tags After import, you can edit multiple tags at once: ### Step 1 — Select Multiple Tags In the Tags list, tick the checkboxes on multiple rows. Use Shift+Click to select a range. The bulk action bar appears at the bottom of the screen. ### Step 2 — Apply Bulk Changes You can change **Engineering Unit**, ** Alarm Limits**, ** Equipment Assignment**, or ** Controller Assignment** across all selected tags simultaneously. Confirm in the dialog. A change log entry is created for each tag (ISA-18.2 audit trail). ### What's Next? | href | label | desc | |---|---|---| | /dashboard/docs/live-connection | Go Live | Subscribe tags to see live PLC values | | /dashboard/docs/ladder-logic | Ladder Logic | Write LD control logic using your new tags | | /dashboard/docs/tag-binding | HMI Tag Binding | Bind tags to SCADA symbols and faceplates |

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library