2 Conveyor Packaging — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 35 views
# 2 Conveyor Packaging — Usage Guide
## Overview
Two-conveyor packaging cell with product counting, reject divert gate, and accumulation handling. The infeed conveyor pauses when the downstream path is blocked, while the outfeed continues when permitted.
## Commissioning
1. Verify product sensor edge counting accuracy
2. Trigger reject condition and confirm divert gate timing
3. Block downstream sensor and verify infeed stops without nuisance trips
---
## Control Logic — Vendor-Agnostic Pseudocode
# 2 Conveyor Packaging — Logic
## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2
## Scan Rate: 10ms | Pattern: count, divert, accumulate
```
ROUTINE: TwoConveyorPackaging
SCAN_RATE: 10ms
// SECTION 1 — PRODUCT COUNTING
PE_EDGE := PE_PRODUCT AND NOT PE_PRODUCT_PREV
PE_PRODUCT_PREV := PE_PRODUCT
IF PE_EDGE THEN PRODUCT_COUNT := PRODUCT_COUNT + 1 END_IF
// SECTION 2 — ACCUMULATION CONTROL
IF DOWNSTREAM_BLOCKED THEN
CONV_INFEED_CMD := FALSE
SET_ALARM(ALM_ACCUMULATION, MEDIUM)
ELSE
CONV_INFEED_CMD := AUTO_MODE
END_IF
CONV_OUTFEED_CMD := AUTO_MODE AND NOT ESTOP_ACTIVE
// SECTION 3 — DIVERT LOGIC
IF REJECT_SENSOR THEN
DIVERT_GATE_CMD := TRUE
DIVERT_TMR := DIVERT_TMR + 1
IF DIVERT_TMR >= DIVERT_TIME_TICKS THEN
DIVERT_GATE_CMD := FALSE
DIVERT_TMR := 0
REJECT_COUNT := REJECT_COUNT + 1
END_IF
END_IF
// SECTION 4 — ALARMS
IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF
IF JAM_SENSOR THEN SET_ALARM(ALM_JAM, HIGH) END_IF
// SECTION 5 — HMI OUTPUTS
HMI_PRODUCT_COUNT := PRODUCT_COUNT
HMI_REJECT_COUNT := REJECT_COUNT
HMI_INFEED := CONV_INFEED_CMD
HMI_OUTFEED := CONV_OUTFEED_CMD
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE,
ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0
PE_PRODUCT,Product Photoeye,BOOL,input,,,,FALSE,DI:0:0.1
PE_PRODUCT_PREV,Previous Product Photoeye State,BOOL,internal,,,,FALSE,
PE_EDGE,Product Rising Edge,BOOL,calculated,,,,FALSE,
DOWNSTREAM_BLOCKED,Downstream Blocked Sensor,BOOL,input,,,,FALSE,DI:0:0.2
JAM_SENSOR,Jam Detection Sensor,BOOL,input,,,,FALSE,DI:0:0.3
REJECT_SENSOR,Reject Qualification Sensor,BOOL,input,,,,FALSE,DI:0:0.4
CONV_INFEED_CMD,Infeed Conveyor Command,BOOL,output,,,,FALSE,DO:1:0.0
CONV_OUTFEED_CMD,Outfeed Conveyor Command,BOOL,output,,,,FALSE,DO:1:0.1
DIVERT_GATE_CMD,Reject Divert Gate Command,BOOL,output,,,,FALSE,DO:1:0.2
DIVERT_TMR,Divert Gate Timer,INT,internal,,0,1000,0,
DIVERT_TIME_TICKS,Divert Gate Open Duration,INT,internal,,0,1000,50,
PRODUCT_COUNT,Accepted Product Count,DINT,internal,,0,999999,0,
REJECT_COUNT,Rejected Product Count,DINT,internal,,0,999999,0,
ALM_ACCUMULATION,Accumulation Alarm,BOOL,calculated,,,,FALSE,
ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE,
ALM_JAM,Jam Alarm,BOOL,calculated,,,,FALSE,
HMI_PRODUCT_COUNT,HMI: Product Count,DINT,output,,0,999999,0,
HMI_REJECT_COUNT,HMI: Reject Count,DINT,output,,0,999999,0,
HMI_INFEED,HMI: Infeed Conveyor,BOOL,output,,,,FALSE,
HMI_OUTFEED,HMI: Outfeed Conveyor,BOOL,output,,,,FALSE,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Packaging conveyors stopped.,0s,No
ALM_JAM,JAM_SENSOR = TRUE,N/A,high,equipment,Product jam detected. Stop line and clear blockage.,1s,No
ALM_ACCUMULATION,DOWNSTREAM_BLOCKED = TRUE,N/A,medium,process,Outfeed blocked. Infeed paused to avoid accumulation.,0s,Yes
```