Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Conveyorsindustrial-automation

2 Conveyor Packaging — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 35 views

# 2 Conveyor Packaging — Usage Guide ## Overview Two-conveyor packaging cell with product counting, reject divert gate, and accumulation handling. The infeed conveyor pauses when the downstream path is blocked, while the outfeed continues when permitted. ## Commissioning 1. Verify product sensor edge counting accuracy 2. Trigger reject condition and confirm divert gate timing 3. Block downstream sensor and verify infeed stops without nuisance trips --- ## Control Logic — Vendor-Agnostic Pseudocode # 2 Conveyor Packaging — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 10ms | Pattern: count, divert, accumulate ``` ROUTINE: TwoConveyorPackaging SCAN_RATE: 10ms // SECTION 1 — PRODUCT COUNTING PE_EDGE := PE_PRODUCT AND NOT PE_PRODUCT_PREV PE_PRODUCT_PREV := PE_PRODUCT IF PE_EDGE THEN PRODUCT_COUNT := PRODUCT_COUNT + 1 END_IF // SECTION 2 — ACCUMULATION CONTROL IF DOWNSTREAM_BLOCKED THEN CONV_INFEED_CMD := FALSE SET_ALARM(ALM_ACCUMULATION, MEDIUM) ELSE CONV_INFEED_CMD := AUTO_MODE END_IF CONV_OUTFEED_CMD := AUTO_MODE AND NOT ESTOP_ACTIVE // SECTION 3 — DIVERT LOGIC IF REJECT_SENSOR THEN DIVERT_GATE_CMD := TRUE DIVERT_TMR := DIVERT_TMR + 1 IF DIVERT_TMR >= DIVERT_TIME_TICKS THEN DIVERT_GATE_CMD := FALSE DIVERT_TMR := 0 REJECT_COUNT := REJECT_COUNT + 1 END_IF END_IF // SECTION 4 — ALARMS IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF IF JAM_SENSOR THEN SET_ALARM(ALM_JAM, HIGH) END_IF // SECTION 5 — HMI OUTPUTS HMI_PRODUCT_COUNT := PRODUCT_COUNT HMI_REJECT_COUNT := REJECT_COUNT HMI_INFEED := CONV_INFEED_CMD HMI_OUTFEED := CONV_OUTFEED_CMD END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 PE_PRODUCT,Product Photoeye,BOOL,input,,,,FALSE,DI:0:0.1 PE_PRODUCT_PREV,Previous Product Photoeye State,BOOL,internal,,,,FALSE, PE_EDGE,Product Rising Edge,BOOL,calculated,,,,FALSE, DOWNSTREAM_BLOCKED,Downstream Blocked Sensor,BOOL,input,,,,FALSE,DI:0:0.2 JAM_SENSOR,Jam Detection Sensor,BOOL,input,,,,FALSE,DI:0:0.3 REJECT_SENSOR,Reject Qualification Sensor,BOOL,input,,,,FALSE,DI:0:0.4 CONV_INFEED_CMD,Infeed Conveyor Command,BOOL,output,,,,FALSE,DO:1:0.0 CONV_OUTFEED_CMD,Outfeed Conveyor Command,BOOL,output,,,,FALSE,DO:1:0.1 DIVERT_GATE_CMD,Reject Divert Gate Command,BOOL,output,,,,FALSE,DO:1:0.2 DIVERT_TMR,Divert Gate Timer,INT,internal,,0,1000,0, DIVERT_TIME_TICKS,Divert Gate Open Duration,INT,internal,,0,1000,50, PRODUCT_COUNT,Accepted Product Count,DINT,internal,,0,999999,0, REJECT_COUNT,Rejected Product Count,DINT,internal,,0,999999,0, ALM_ACCUMULATION,Accumulation Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, ALM_JAM,Jam Alarm,BOOL,calculated,,,,FALSE, HMI_PRODUCT_COUNT,HMI: Product Count,DINT,output,,0,999999,0, HMI_REJECT_COUNT,HMI: Reject Count,DINT,output,,0,999999,0, HMI_INFEED,HMI: Infeed Conveyor,BOOL,output,,,,FALSE, HMI_OUTFEED,HMI: Outfeed Conveyor,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Packaging conveyors stopped.,0s,No ALM_JAM,JAM_SENSOR = TRUE,N/A,high,equipment,Product jam detected. Stop line and clear blockage.,1s,No ALM_ACCUMULATION,DOWNSTREAM_BLOCKED = TRUE,N/A,medium,process,Outfeed blocked. Infeed paused to avoid accumulation.,0s,Yes ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library