Multi Output Permissive Gate — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 36 views

# Multi Output Permissive Gate — Usage Guide ## Overview Shared permissive template that fans a common safety and readiness gate to multiple downstream outputs. Useful where several actuators must only operate when the same safety conditions are true. ## Commissioning 1. Verify each common permissive input independently 2. Confirm all output requests drop immediately when the permissive is lost 3. Avoid using this template as a substitute for certified safety hardware where required by risk assessment --- ## Control Logic — Vendor-Agnostic Pseudocode # Multi Output Permissive Gate — Logic ## Standards: IEC 61131-3 | IEC 61508 ## Scan Rate: 10ms | Pattern: shared permissive fan-out to multiple outputs ``` ROUTINE: MultiOutputPermissiveGate SCAN_RATE: 10ms // SECTION 1 — COMMON PERMISSIVE COMMON_PERMIT := MASTER_ENABLE AND NOT ESTOP_ACTIVE AND GUARD_CLOSED AND POWER_HEALTHY // SECTION 2 — FAN-OUT OUT1_CMD := REQ1 AND COMMON_PERMIT OUT2_CMD := REQ2 AND COMMON_PERMIT OUT3_CMD := REQ3 AND COMMON_PERMIT OUT4_CMD := REQ4 AND COMMON_PERMIT // SECTION 3 — ALARMS IF NOT COMMON_PERMIT AND (REQ1 OR REQ2 OR REQ3 OR REQ4) THEN SET_ALARM(ALM_PERMIT_LOST, HIGH) END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF // SECTION 4 — HMI HMI_COMMON_PERMIT := COMMON_PERMIT HMI_OUT1 := OUT1_CMD HMI_OUT2 := OUT2_CMD HMI_OUT3 := OUT3_CMD HMI_OUT4 := OUT4_CMD END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address MASTER_ENABLE,Master Enable,BOOL,input,,,,FALSE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 GUARD_CLOSED,Guard Closed Interlock,BOOL,input,,,,TRUE,DI:0:0.1 POWER_HEALTHY,Power Supply Healthy,BOOL,input,,,,TRUE,DI:0:0.2 REQ1,Output 1 Request,BOOL,input,,,,FALSE, REQ2,Output 2 Request,BOOL,input,,,,FALSE, REQ3,Output 3 Request,BOOL,input,,,,FALSE, REQ4,Output 4 Request,BOOL,input,,,,FALSE, COMMON_PERMIT,Common Permissive,BOOL,calculated,,,,FALSE, OUT1_CMD,Output 1 Command,BOOL,output,,,,FALSE,DO:1:0.0 OUT2_CMD,Output 2 Command,BOOL,output,,,,FALSE,DO:1:0.1 OUT3_CMD,Output 3 Command,BOOL,output,,,,FALSE,DO:1:0.2 OUT4_CMD,Output 4 Command,BOOL,output,,,,FALSE,DO:1:0.3 ALM_PERMIT_LOST,Common Permit Lost Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_COMMON_PERMIT,HMI: Common Permit,BOOL,output,,,,FALSE, HMI_OUT1,HMI: Output 1,BOOL,output,,,,FALSE, HMI_OUT2,HMI: Output 2,BOOL,output,,,,FALSE, HMI_OUT3,HMI: Output 3,BOOL,output,,,,FALSE, HMI_OUT4,HMI: Output 4,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. All gated outputs inhibited.,0s,No ALM_PERMIT_LOST,Any output requested while COMMON_PERMIT = FALSE,N/A,high,safety,Output request blocked by lost permissive. Investigate interlocks before re-enabling.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library