Engineering Library
Procedures, PLC and HMI code, drawings, and field-proven fixes shared by working controls and instrumentation engineers. Community contributions publish immediately and can be flagged for review. Membership is free — sign in to download, rate, and contribute.
126 published contributions
- Read more
VFD Motor Speed Control — Engineering Guide
VFD Motor Speed Control
TSIMEREZIVO Team · 47 views · 0 downloads
- Read more
Ladder Logic (LD) Programming — Engineering Guide
Ladder Logic LD Programming
TSIMEREZIVO Team · 52 views · 0 downloads
- Read more
Boiler Drum Level — 3-Element Control — Engineering Guide
Boiler Drum Level — 3 Element Control
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Conveyor Pull-Cord Safety Circuit — Engineering Guide
Conveyor Pull Cord Safety Circuit
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Connection Diagnostics — Engineering Guide
Connection Diagnostics
TSIMEREZIVO Team · 48 views · 0 downloads
- Read more
Management of Change (MOC) — Engineering Guide
Management of Change MOC
TSIMEREZIVO Team · 36 views · 0 downloads
- Read more
Alarm Investigation & Management — Engineering Guide
Alarm Investigation & Management
TSIMEREZIVO Team · 51 views · 0 downloads
- Read more
I/O Rack & Module Mapping — Engineering Guide
I/O Rack & Module Mapping
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Filter Press & Sludge Dewatering Sequence — Control Design
Operate a plate frame or belt filter press to dewater municipal wastewater sludge. Thickened sludge 4–6% solids is pumped into filter press; applied pressure 10–20 bar forces water out, leaving dry cake 15–25% solids tha…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Chemical Disinfection & Residual Monitoring — Control Design
Automatically inject chlorine or ozone into treated water to inactivate pathogens bacteria, viruses, protozoa . Maintain residual disinfectant 0.2–0.5 mg/L free chlorine throughout distribution system. Continuously monit…
TSIMEREZIVO Team · 42 views · 0 downloads
- Read more
Multi-Pump Distribution System with Pressure Regulation — Control Design
Manage water distribution from treatment plant to customers via a variable speed pump network . System must maintain constant downstream pressure despite fluctuating demand day: 700 m³/h peak; night: 80 m³/h base . Uses …
TSIMEREZIVO Team · 64 views · 0 downloads
- Read more
Boiler Drum Level Control (3-Element Control) — Control Design
Three element feedwater control for boiler drum level. Most safety critical control in power plants.
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Air/Fuel Ratio Trim Cascade Control — Control Design
Fine tune air/fuel ratio lambda for optimal combustion energy recovery while meeting NOₓ emissions limits. This is the secondary loop extension to Template 01 Furnace Combustion Pressure , explicitly managing stoichiomet…
TSIMEREZIVO Team · 61 views · 0 downloads
- Read more
Boiler Feedwater Pump Pressure Control — Control Design
Maintain boiler feedwater pump discharge pressure at precisely 180–200 bar to overcome boiler steam drum pressure 175 bar at design plus pipe friction losses ~15–20 bar while minimizing energy waste. Too high = relief va…
TSIMEREZIVO Team · 43 views · 0 downloads
- Read more
Deaerator Heater Level Control — Control Design
Maintain the deaerator feed water tank at a constant level typically 50–60% of vessel to ensure reliable suction pressure for the boiler feedwater pump NPSH—Net Positive Suction Head availability . The deaerator also hea…
TSIMEREZIVO Team · 45 views · 0 downloads
- Read more
Turbine Speed Governor (Proportional Throttle Valve Control) — Control Design
Regulate turbine inlet steam flow via a proportional throttle valve to maintain constant turbine shaft speed
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Superheater Outlet Temperature Control (Spray Water Attemperator) — Control Design
Maintain superheated steam outlet temperature at exactly setpoint ±3°C typical using proportional
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Furnace Combustion Pressure Control (O₂ Trim) — Control Design
Maintain furnace combustion air pressure within ±0.5 inches water column ±125 Pa setpoint
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Subsea Umbilical Fault Isolation — Control Design
A subsea production manifold is connected to topside via umbilical hydraulic control lines, power cables, fiber optics bundled . If umbilical ruptures, hydraulic pressure is lost, and all remotely operated valves ROVs go…
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Gas Separation Vessel — Control Design
Three phase separator removes liquids oil + water from raw gas stream under subsonic conditions. Liquid level is controlled via dump valve to prevent slugging downstream compressor inlet while maintaining interface betwe…
TSIMEREZIVO Team · 50 views · 0 downloads
- Read more
Gas Compression & Discharge Throttling — Control Design
Operate centrifugal or reciprocating gas compressor to maintain pipeline discharge pressure setpoint typically 800–1500 psia while protecting equipment from surge compressor pre surge condition and limiting discharge tem…
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Wellhead Pressure Management & Production Optimization — Control Design
Automatically regulate wellhead backpressure tubing head pressure to optimize production rate while protecting subsurface equipment and preventing sand production. Most oil/gas wells produce under pressure differential: …
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Water Recycling Circuit & Density Balance — Control Design
Mining operations recycle water from thickener overflow back to upstream processes crusher, mill to conserve water and recover valuable solids from clarified water. However, recycled water carries suspended fines and rea…
TSIMEREZIVO Team · 32 views · 0 downloads
- Read more
Crusher Jaw Gap & Feed Rate Optimization — Control Design
A jaw crusher belt fed ore hopper → primary crusher → stockpile must maintain optimal jaw gap 2–6 cm typical to maximize throughput while preventing overload motor stall, frame damage . Jaw gap is adjustable via eccentri…
TSIMEREZIVO Team · 43 views · 0 downloads
Worked on a project? Share what you learned.
Upload procedures, code, drawings — or post the fix that took you a day to find. Your experience is the library.