Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Conveyorsindustrial-automation

Product Delivery System — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 37 views

# Product Delivery System — Usage Guide ## Overview Queue-based product delivery template for pick, buffer, convey, and dispatch applications. Tracks queued items and drives a conveyor plus pusher actuator when dispatch demand is present. ## Commissioning 1. Verify queue count increments at pick and decrements at dispatch 2. Confirm pusher pulse width is sufficient for clean dispatch without double-push 3. Set queue high limit based on physical buffer capacity --- ## Control Logic — Vendor-Agnostic Pseudocode # Product Delivery System — Logic ## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2 ## Scan Rate: 10ms | Pattern: pick, queue, convey, dispatch ``` ROUTINE: ProductDeliverySystem SCAN_RATE: 10ms // SECTION 1 — QUEUE MANAGEMENT PICK_EDGE := PICK_SENSOR AND NOT PICK_SENSOR_PREV PICK_SENSOR_PREV := PICK_SENSOR IF PICK_EDGE THEN QUEUE_COUNT := QUEUE_COUNT + 1 END_IF DISPATCH_EDGE := DISPATCH_SENSOR AND NOT DISPATCH_SENSOR_PREV DISPATCH_SENSOR_PREV := DISPATCH_SENSOR IF DISPATCH_EDGE AND QUEUE_COUNT > 0 THEN QUEUE_COUNT := QUEUE_COUNT - 1 END_IF // SECTION 2 — CONVEYOR / PUSHER CONTROL CONV_CMD := AUTO_MODE AND NOT ESTOP_ACTIVE AND QUEUE_COUNT > 0 IF DISPATCH_REQUEST AND QUEUE_COUNT > 0 THEN PUSHER_CMD := TRUE PUSHER_TMR := PUSHER_TMR + 1 IF PUSHER_TMR >= PUSHER_TIME_TICKS THEN PUSHER_CMD := FALSE PUSHER_TMR := 0 END_IF END_IF // SECTION 3 — ALARMS IF QUEUE_COUNT >= QUEUE_HIGH_LIMIT THEN SET_ALARM(ALM_QUEUE_HIGH, MEDIUM) END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF // SECTION 4 — HMI OUTPUTS HMI_QUEUE_COUNT := QUEUE_COUNT HMI_CONV := CONV_CMD HMI_PUSHER := PUSHER_CMD END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 PICK_SENSOR,Pick Station Product Sensor,BOOL,input,,,,FALSE,DI:0:0.1 PICK_SENSOR_PREV,Previous Pick Sensor State,BOOL,internal,,,,FALSE, PICK_EDGE,Pick Sensor Rising Edge,BOOL,calculated,,,,FALSE, DISPATCH_SENSOR,Dispatch Confirmation Sensor,BOOL,input,,,,FALSE,DI:0:0.2 DISPATCH_SENSOR_PREV,Previous Dispatch Sensor State,BOOL,internal,,,,FALSE, DISPATCH_EDGE,Dispatch Sensor Rising Edge,BOOL,calculated,,,,FALSE, DISPATCH_REQUEST,Dispatch Request,BOOL,input,,,,FALSE, CONV_CMD,Delivery Conveyor Command,BOOL,output,,,,FALSE,DO:1:0.0 PUSHER_CMD,Dispatch Pusher Command,BOOL,output,,,,FALSE,DO:1:0.1 PUSHER_TMR,Pusher Pulse Timer,INT,internal,,0,1000,0, PUSHER_TIME_TICKS,Pusher Extend Time (10ms ticks),INT,internal,,0,1000,40, QUEUE_COUNT,Queued Product Count,DINT,internal,,0,999999,0, QUEUE_HIGH_LIMIT,High Queue Alarm Threshold,DINT,internal,,0,999999,20, ALM_QUEUE_HIGH,Queue High Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_QUEUE_COUNT,HMI: Queue Count,DINT,output,,0,999999,0, HMI_CONV,HMI: Conveyor Status,BOOL,output,,,,FALSE, HMI_PUSHER,HMI: Pusher Status,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Delivery motion inhibited.,0s,No ALM_QUEUE_HIGH,QUEUE_COUNT >= QUEUE_HIGH_LIMIT,20,medium,process,Queue high. Downstream dispatch demand is insufficient for incoming rate.,5s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library