Product Delivery System — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 37 views
# Product Delivery System — Usage Guide
## Overview
Queue-based product delivery template for pick, buffer, convey, and dispatch applications. Tracks queued items and drives a conveyor plus pusher actuator when dispatch demand is present.
## Commissioning
1. Verify queue count increments at pick and decrements at dispatch
2. Confirm pusher pulse width is sufficient for clean dispatch without double-push
3. Set queue high limit based on physical buffer capacity
---
## Control Logic — Vendor-Agnostic Pseudocode
# Product Delivery System — Logic
## Standards: IEC 61131-3 | ISA-5.1 | ISA-18.2
## Scan Rate: 10ms | Pattern: pick, queue, convey, dispatch
```
ROUTINE: ProductDeliverySystem
SCAN_RATE: 10ms
// SECTION 1 — QUEUE MANAGEMENT
PICK_EDGE := PICK_SENSOR AND NOT PICK_SENSOR_PREV
PICK_SENSOR_PREV := PICK_SENSOR
IF PICK_EDGE THEN QUEUE_COUNT := QUEUE_COUNT + 1 END_IF
DISPATCH_EDGE := DISPATCH_SENSOR AND NOT DISPATCH_SENSOR_PREV
DISPATCH_SENSOR_PREV := DISPATCH_SENSOR
IF DISPATCH_EDGE AND QUEUE_COUNT > 0 THEN QUEUE_COUNT := QUEUE_COUNT - 1 END_IF
// SECTION 2 — CONVEYOR / PUSHER CONTROL
CONV_CMD := AUTO_MODE AND NOT ESTOP_ACTIVE AND QUEUE_COUNT > 0
IF DISPATCH_REQUEST AND QUEUE_COUNT > 0 THEN
PUSHER_CMD := TRUE
PUSHER_TMR := PUSHER_TMR + 1
IF PUSHER_TMR >= PUSHER_TIME_TICKS THEN
PUSHER_CMD := FALSE
PUSHER_TMR := 0
END_IF
END_IF
// SECTION 3 — ALARMS
IF QUEUE_COUNT >= QUEUE_HIGH_LIMIT THEN SET_ALARM(ALM_QUEUE_HIGH, MEDIUM) END_IF
IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF
// SECTION 4 — HMI OUTPUTS
HMI_QUEUE_COUNT := QUEUE_COUNT
HMI_CONV := CONV_CMD
HMI_PUSHER := PUSHER_CMD
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
AUTO_MODE,Automatic Mode Enable,BOOL,input,,,,TRUE,
ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0
PICK_SENSOR,Pick Station Product Sensor,BOOL,input,,,,FALSE,DI:0:0.1
PICK_SENSOR_PREV,Previous Pick Sensor State,BOOL,internal,,,,FALSE,
PICK_EDGE,Pick Sensor Rising Edge,BOOL,calculated,,,,FALSE,
DISPATCH_SENSOR,Dispatch Confirmation Sensor,BOOL,input,,,,FALSE,DI:0:0.2
DISPATCH_SENSOR_PREV,Previous Dispatch Sensor State,BOOL,internal,,,,FALSE,
DISPATCH_EDGE,Dispatch Sensor Rising Edge,BOOL,calculated,,,,FALSE,
DISPATCH_REQUEST,Dispatch Request,BOOL,input,,,,FALSE,
CONV_CMD,Delivery Conveyor Command,BOOL,output,,,,FALSE,DO:1:0.0
PUSHER_CMD,Dispatch Pusher Command,BOOL,output,,,,FALSE,DO:1:0.1
PUSHER_TMR,Pusher Pulse Timer,INT,internal,,0,1000,0,
PUSHER_TIME_TICKS,Pusher Extend Time (10ms ticks),INT,internal,,0,1000,40,
QUEUE_COUNT,Queued Product Count,DINT,internal,,0,999999,0,
QUEUE_HIGH_LIMIT,High Queue Alarm Threshold,DINT,internal,,0,999999,20,
ALM_QUEUE_HIGH,Queue High Alarm,BOOL,calculated,,,,FALSE,
ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE,
HMI_QUEUE_COUNT,HMI: Queue Count,DINT,output,,0,999999,0,
HMI_CONV,HMI: Conveyor Status,BOOL,output,,,,FALSE,
HMI_PUSHER,HMI: Pusher Status,BOOL,output,,,,FALSE,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Delivery motion inhibited.,0s,No
ALM_QUEUE_HIGH,QUEUE_COUNT >= QUEUE_HIGH_LIMIT,20,medium,process,Queue high. Downstream dispatch demand is insufficient for incoming rate.,5s,No
```