Engineering Library
Procedures, PLC and HMI code, drawings, and field-proven fixes shared by working controls and instrumentation engineers. Community contributions publish immediately and can be flagged for review. Membership is free — sign in to download, rate, and contribute.
126 published contributions
- Read more
PID Loop Configuration — Engineering Guide
PID Loop Configuration
TSIMEREZIVO Team · 51 views · 0 downloads
- Read more
Structured Text (ST) Programming — Engineering Guide
Structured Text ST Programming
TSIMEREZIVO Team · 54 views · 0 downloads
- Read more
Management of Change (MOC) — Engineering Guide
Management of Change MOC
TSIMEREZIVO Team · 36 views · 0 downloads
- Read more
Filter Press & Sludge Dewatering Sequence — Control Design
Operate a plate frame or belt filter press to dewater municipal wastewater sludge. Thickened sludge 4–6% solids is pumped into filter press; applied pressure 10–20 bar forces water out, leaving dry cake 15–25% solids tha…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Chemical Disinfection & Residual Monitoring — Control Design
Automatically inject chlorine or ozone into treated water to inactivate pathogens bacteria, viruses, protozoa . Maintain residual disinfectant 0.2–0.5 mg/L free chlorine throughout distribution system. Continuously monit…
TSIMEREZIVO Team · 43 views · 0 downloads
- Read more
Membrane Filtration with Automated Backwash Sequencing — Control Design
Operate crossflow ultrafiltration UF or microfiltration MF membrane systems with pressure driven permeate production and air assisted backwashing to restore permeability. Membrane fouling increases transmembrane pressure…
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Multi-Pump Distribution System with Pressure Regulation — Control Design
Manage water distribution from treatment plant to customers via a variable speed pump network . System must maintain constant downstream pressure despite fluctuating demand day: 700 m³/h peak; night: 80 m³/h base . Uses …
TSIMEREZIVO Team · 66 views · 0 downloads
- Read more
Activated Sludge Aeration Basin Control — Control Design
Maintain dissolved oxygen DO setpoint in activated sludge reactor tank through automatic aeration control. The aeration basin is the heart of wastewater treatment , where microorganisms consume organic pollutants BOD und…
TSIMEREZIVO Team · 45 views · 0 downloads
- Read more
Aeration Basin Control — Control Design
Dissolved oxygen DO control in an activated sludge aeration basin for biological wastewater treatment. Covers blower/diffuser DO control, MLSS mixed liquor suspended solids monitoring, ammonia based aeration control ABAC…
TSIMEREZIVO Team · 47 views · 0 downloads
- Read more
Filtration System Control — Control Design
Automated control of a multi media pressure filtration system for potable water or tertiary wastewater treatment. Covers normal filtration, turbidity monitoring, backwash sequencing, and filter to waste FTW operations.
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Load / Frequency Control (AGC / LFC) — Control Design
Automatic Generation Control AGC and Load Frequency Control LFC for a generating unit participating in primary, secondary, and tertiary frequency response. Covers Area Control Error ACE computation, generation ramp manag…
TSIMEREZIVO Team · 37 views · 0 downloads
- Read more
Pulverized Coal Mill Outlet (PA) Flow Control — Control Design
Regulate primary air PA flow and temperature from the coal mill to maintain consistent coal in air concentration fuel feed to the furnace. The mill grinds raw coal into powder ~200 µm , mixes with hot air to fluidize par…
TSIMEREZIVO Team · 54 views · 0 downloads
- Read more
Air/Fuel Ratio Trim Cascade Control — Control Design
Fine tune air/fuel ratio lambda for optimal combustion energy recovery while meeting NOₓ emissions limits. This is the secondary loop extension to Template 01 Furnace Combustion Pressure , explicitly managing stoichiomet…
TSIMEREZIVO Team · 64 views · 0 downloads
- Read more
Subsea Umbilical Fault Isolation — Control Design
A subsea production manifold is connected to topside via umbilical hydraulic control lines, power cables, fiber optics bundled . If umbilical ruptures, hydraulic pressure is lost, and all remotely operated valves ROVs go…
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Gas Separation Vessel — Control Design
Three phase separator removes liquids oil + water from raw gas stream under subsonic conditions. Liquid level is controlled via dump valve to prevent slugging downstream compressor inlet while maintaining interface betwe…
TSIMEREZIVO Team · 51 views · 0 downloads
- Read more
Pipeline Flow Metering & Leak Detection — Control Design
Continuously measure crude/gas flow through transmission pipeline orifice plate, turbine, or ultrasonic meter and detect leaks by comparing expected flow from surface + subsurface meters against actual outlet flow. A 2% …
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Crude Oil Tank Level & Custody Transfer Metering — Control Design
Automatically measure crude oil tank inventory and compute net barrels accounting for temperature, API gravity, water content for custody transfer ownership handoff between operator and buyer . Tank level measurement mus…
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Gas Compression & Discharge Throttling — Control Design
Operate centrifugal or reciprocating gas compressor to maintain pipeline discharge pressure setpoint typically 800–1500 psia while protecting equipment from surge compressor pre surge condition and limiting discharge tem…
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Wellhead Pressure Management & Production Optimization — Control Design
Automatically regulate wellhead backpressure tubing head pressure to optimize production rate while protecting subsurface equipment and preventing sand production. Most oil/gas wells produce under pressure differential: …
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Water Recycling Circuit & Density Balance — Control Design
Mining operations recycle water from thickener overflow back to upstream processes crusher, mill to conserve water and recover valuable solids from clarified water. However, recycled water carries suspended fines and rea…
TSIMEREZIVO Team · 33 views · 0 downloads
- Read more
Thickener Rake Torque & Underflow Clarity — Control Design
A thickener settling tank, 20–50 m diameter allows coarse solids to settle under gravity while water overflows as clarified product. A rotating rake mechanism slowly scrapes settled solids toward a central pump cone unde…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Crusher Jaw Gap & Feed Rate Optimization — Control Design
A jaw crusher belt fed ore hopper → primary crusher → stockpile must maintain optimal jaw gap 2–6 cm typical to maximize throughput while preventing overload motor stall, frame damage . Jaw gap is adjustable via eccentri…
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Flotation Cell Pulp Density & Air Control — Control Design
Froth flotation cells separate valuable minerals sulfides, oxides from gangue worthless rock by floating mineral particles to the surface and collecting froth overflow. Cell performance depends critically on maintaining …
TSIMEREZIVO Team · 35 views · 0 downloads
- Read more
Conveyor Load Monitoring & Auto-Speed Regulation — Control Design
A long haul conveyor belt crusher discharge → mill feed or stockpile can fail if overloaded. This template monitors belt load via motor current draw and automatically modulates the belt speed downward if approaching maxi…
TSIMEREZIVO Team · 45 views · 0 downloads