Economizer Outlet Temperature Control — Control Design

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 45 views

# TSIMEREZIVO Template: Economizer Outlet Temperature Control **Category:** Power Plant | **Industry:** Thermal Power Generation | **Language:** Ladder / Structured Text --- ## 📋 Overview ### Purpose Maintain boiler feedwater temperature exiting the economizer (exhaust gas heat exchanger) at 210–220°C to preheat incoming cold feed water from the deaerator (160°C). This recovers 10–15% of the boiler's thermal energy that would otherwise be lost up the stack, improving overall plant efficiency by 2–3 percentage points. ### Typical Application - **Plant:** 100–300 MWe coal/NG coal-fired boiler - **Feedwater Inlet to Economizer:** 160°C (from deaerator) - **Feedwater Outlet (Economizer Exit):** 210–220°C target - **Flue Gas Inlet:** 400–450°C (after superheater tubes) - **Flue Gas Outlet:** 150–160°C (before air preheater; pinch point) - **Control Method:** Bypass valve around economizer tubes OR staged tube arrangement ### Energy Impact Every 10°C rise in feed water temperature = **0.8–1.2% improvement in Rankine cycle efficiency** At 200 MWe plant: - 1% efficiency gain = 2 MWe additional output - 2 MWe × $50/MWh × 8,000 h/year = **$800,000/year fuel savings** --- ## 🎯 Control Philosophy ### Key Equations **Heat Recovery (First Law Thermodynamics):** ``` Q [MW] = ṁ_feedwater [kg/s] × c_p × (T_outlet − T_inlet) = 100 kg/s × 4.18 kJ/kg·°C × (220 − 160)°C = 100 × 4.18 × 60 = 25 MW of heat transferred Higher outlet T → more heat recovery → less fuel burned in furnace ``` **Economizer Outlet Temperature Relationship to Load:** ``` T_outlet ∝ (Flue Gas Mass Flow) / (Feedwater Mass Flow) ∝ Load% At 25% load: ṁ_flue↓, ṁ_feedwater↓ → BUT ratio changes → T might rise OR fall At 100% load: Maximum flue gas and feedwater flow → Balanced heat transfer ``` **Pinch Point (Thermodynamic Limit):** ``` Pinch Point = T_flue_outlet − T_feedwater_outlet = 160°C − 220°C = −60°C ??? Wait—feedwater GAINS heat, so T_feedwater < T_flue at every point. More precise: Minimum approach: T_flue_pinch − T_feedwater = 15−20°C (design margin) Typical design: Pinch point at economizer inlet If attempt T_outlet > 225°C: → Pinch point becomes <15°C → Heat transfer degrades (tubes less effective) → May cause tube corrosion (if outlet steam pressure = saturation, water boils on tube surface) ``` ### Control Strategy: **Proportional Bypass Valve** ``` Goal: Keep outlet T at 220°C (optimal) Method 1: Proportional bypass valve around tubes ┌─── Economizer tubes (hot path) ───┐ ╭┴─ │ Inlet─→ BYPASS VALVE (0-100% open)─┬─→ Outlet │ (cold path) │ └────────────────────────────┐ Bypass % = 100% − (Desired heating %) If T_outlet too LOW: Close bypass → More flow through hot tubes → T rises If T_outlet too HIGH: Open bypass → Bypass around tubes → T drops ``` **PID Tuning (Temperature Control):** ``` Kp = 0.25 (Proportional: moderate response) Ki = 0.012 (Integral: slow thermal compensation) Kd = 0.001 (Derivative: small, reduces overshoot on transients) Scan = 2 seconds (slow thermal response allows slow PLC scan) ``` --- ## 🏗️ Control Logic ### Pseudocode: Economizer Outlet Temperature Control ```pascal PROGRAM EconomizerOutletTemperatureControl; { ========== DECLARATIONS ========== } VAR -- INPUT SENSORS economizer_outlet_temp : REAL; { 100-250 °C, RTD in water outlet } economizer_inlet_temp : REAL; { 100-200 °C, RTD in water inlet (deaerator out) } flue_gas_inlet_temp : REAL; { 300-500°C, thermocouple before economizer } flue_gas_outlet_temp : REAL; { 100-200°C, thermocouple after economizer } feedwater_flow : REAL; { 0-300 kg/s, flow meter } flue_gas_flow_est : REAL; { 0-1000 kg/s, estimated from fuel + air } bypass_valve_position : REAL; { 0-100 %, spool feedback } boiler_load_percent : REAL; { 0-100 %, for adaptation } -- CONTROL SETPOINTS econ_temp_sp : REAL := 220.0; { Target outlet temperature } econ_temp_alarm_high : REAL := 230.0; { Protection: tube boiling risk } econ_temp_alarm_low : REAL := 200.0; { Info: poor heat recovery } pinch_point_min : REAL := 15.0; { °C minimum for heat transfer effectiveness } -- CONTROL LOOP temp_error : REAL; temp_error_integral : REAL := 0.0; temp_prev : REAL := 220.0; temp_rate_of_change : REAL; -- PID TUNING kp_econ : REAL := 0.25; ki_econ : REAL := 0.012; kd_econ : REAL := 0.001; integral_limit_hi : REAL := 0.15; integral_limit_lo : REAL := -0.10; scan_time : REAL := 2.0; -- BYPASS VALVE COMMAND bypass_valve_command : REAL; bypass_valve_limited : REAL; bypass_rate_limit : REAL := 1.5; { %/sec } bypass_command_prev : REAL := 40.0; -- TEMPERATURE PROFILE MONITORING econ_delta_t : REAL; { Outlet − Inlet = temperature rise } flue_gas_delta_t : REAL; { Inlet − Outlet = flue gas cooling } overall_effectiveness : REAL; { % of max possible heat transfer } pinch_point_actual : REAL; { °C margin at pinch point } -- LOAD ADAPTATION temp_sp_min_load : REAL := 215.0; { Lower setpoint at light load (less flue gas) } temp_sp_full_load : REAL := 220.0; { Higher setpoint at full load (more flue gas) } load_adapted_sp : REAL; -- OUTPUT COMMANDS bypass_valve_command_final : REAL; BEGIN { ========== SENSOR ACQUISITION ========== } -- Calculate temperature rises econ_delta_t := economizer_outlet_temp − economizer_inlet_temp; flue_gas_delta_t := flue_gas_inlet_temp − flue_gas_outlet_temp; -- Estimate pinch point (minimum approach in economizer) -- Usually occurs at outlet (coldest water meets hottest remaining flue gas) pinch_point_actual := flue_gas_outlet_temp − economizer_outlet_temp; { ========== LOAD-DEPENDENT SETPOINT SCHEDULING ========== } -- At light load: feedwater cooler, less flue gas → setpoint lower -- At full load: feedwater hot, strong flue gas → setpoint higher load_adapted_sp := temp_sp_min_load + ((boiler_load_percent / 100.0) × (temp_sp_full_load − temp_sp_min_load)); { Example: At 50% load: SP = 215 + (0.5 × (220 − 215)) = 215 + 2.5 = 217.5°C } { ========== ERROR CALCULATION ========== } temp_error := load_adapted_sp − economizer_outlet_temp; { ========== PID CONTROL LOOP ========== } -- Proportional term proportional_term := kp_econ * temp_error; -- Integral term (slow correction for steady-state offset) temp_error_integral := temp_error_integral + (ki_econ * temp_error * scan_time); -- Anti-windup IF temp_error_integral > integral_limit_hi THEN temp_error_integral := integral_limit_hi; ELSIF temp_error_integral < integral_limit_lo THEN temp_error_integral := integral_limit_lo; END_IF; -- Derivative term (response to rate of change) IF ABS(temp_error) > 2.0 THEN { Only use derivative if error significant } temp_rate_of_change := (economizer_outlet_temp − temp_prev) / scan_time; derivative_term := kd_econ * temp_rate_of_change; ELSE derivative_term := 0.0; END_IF; -- Combined command (maps to bypass valve %) -- Error positive (T too low) → reduce bypass % (close valve, force more hot tubes) -- Error negative (T too high) → increase bypass % (open valve, divert around tubes) bypass_valve_command := 50.0 − proportional_term − temp_error_integral − derivative_term; { ========== RATE LIMITING ========== } valve_delta := bypass_valve_command − bypass_command_prev; max_delta := bypass_rate_limit * scan_time; IF valve_delta > max_delta THEN bypass_valve_limited := bypass_command_prev + max_delta; ELSIF valve_delta < -max_delta THEN bypass_valve_limited := bypass_command_prev − max_delta; ELSE bypass_valve_limited := bypass_valve_command; END_IF; { ========== OUTPUT LIMITS ========== } IF bypass_valve_limited < 5.0 THEN { At startup, minimum 5% bypass to prevent tube vibration } bypass_valve_command_final := 5.0; ELSIF bypass_valve_limited > 95.0 THEN { Max 95% bypass to ensure some flow through tubes } bypass_valve_command_final := 95.0; ELSE bypass_valve_command_final := bypass_valve_limited; END_IF; { ========== TUBE PROTECTION CHECKS ========== } -- Check 1: Pinch point too tight (approaching boiling condition) IF pinch_point_actual < pinch_point_min THEN { WARN: "Economizer pinch point < {value}°C — heat transfer degrading" } { At 100% bypass, bypass_valve_command_final reaches upper limit } END_IF; -- Check 2: Effectiveness falling (scale/fouling) -- Effectiveness = actual ΔT / (max possible ΔT if infinite surface) -- Max possible: flue gas inlet temp − feedwater inlet temp = 400 − 160 = 240°C overall_effectiveness := econ_delta_t / (flue_gas_inlet_temp − economizer_inlet_temp) × 100.0; IF overall_effectiveness < 60.0 AND boiler_load_percent > 80.0 THEN { WARN: "Economizer effectiveness {value}% — scaling/fouling detected; schedule cleaning" } END_IF; -- Check 3: Temperature oscillating (control instability) IF ABS(temp_rate_of_change) > 1.0 THEN { Rate > 1°C/sec } { WARN: "Economizer outlet temp oscillating — valve hunting or flue gas instability" } END_IF; { ========== ALARMS ========== } IF economizer_outlet_temp > econ_temp_alarm_high THEN { CRITICAL: "Economizer outlet temp HIGH — risk of steam formation in tubes, tube damage" } { ACTION: Increase bypass valve opening (let more flow bypass hot tubes) } END_IF; IF economizer_outlet_temp < econ_temp_alarm_low THEN { WARNING: "Economizer outlet temp low — poor heat recovery; efficiency loss" } { ACTION: Close bypass valve (force more flow through hot tubes) } END_IF; IF bypass_valve_position >= 90.0 AND temp_error > 5.0 THEN { ALARM: "Bypass valve saturated (nearly 100% open) but temp still too low — economizer fouled?" } END_IF; { ========== UPDATE STATE FOR NEXT CYCLE ========== } temp_prev := economizer_outlet_temp; bypass_command_prev := bypass_valve_command_final; { ========== SEND COMMAND ========== } -- Output: bypass_valve_command_final (0-100 % proportional solenoid signal) { ========== LOG EFFICIENCY METRIC ========== } -- Record daily efficiency gain from economizer -- Typical baseline: 75% effectiveness → 2.8% plant efficiency improvement END_PROGRAM; ``` --- ## 🏷️ Tag List | Tag Name | Type | Range | Units | Description | |----------|------|-------|-------|-------------| | `ECON_OUTLET_TEMP` | AI | 100–250 | °C | Feedwater exiting economizer (RTD) | | `ECON_INLET_TEMP` | AI | 100–200 | °C | Feedwater entering economizer | | `FLUE_GAS_INLET_TEMP` | AI | 300–500 | °C | Flue temperature before economizer | | `FLUE_GAS_OUTLET_TEMP` | AI | 100–200 | °C | Flue temperature after economizer | | `FEEDWATER_FLOW` | AI | 0–300 | kg/s | Feedwater mass flow rate | | `BYPASS_VALVE_FEEDBACK` | AI | 0–100 | % | Proportional valve spool position | | `BOILER_LOAD` | AI | 0–100 | % | For setpoint scheduling | --- ## 🚨 Alarm & Trip Matrix | Condition | Threshold | Severity | Action | Recovery | |-----------|-----------|----------|--------|----------| | **Temp High** | > 230°C | 🔴 CRIT | Open bypass valve (cool feed water in tubes) | < 220°C | | **Temp Low** | < 200°C | ⚠️ WARN | Close bypass valve (more hot tube exposure) | > 210°C | | **Pinch Point Tight** | < 15°C | ⚠️ WARN | Effectiveness degrading; fouling likely | > 20°C | | **Effectiveness Low** | < 60 % | ⚠️ WARN | Economizer fouling or scaling; schedule cleaning | > 75% | | **Valve Saturated** | >90% open + T still low | 🔴 CRIT | Economizer heavily fouled; manual water chemistry check | Cleaning required | --- ## 📺 HMI Layout ### Economizer Temperature & Efficiency Monitor ``` ┌────────────────────────────────────────────────┐ │ ECONOMIZER OUTLET TEMPERATURE & HEAT │ ├────────────────────────────────────────────────┤ │ │ │ ╔═════════════ TEMPERATURE PROFILE ════════╗ │ │ ║ Inlet (from Deaerator): 160°C ║ │ │ ║ Outlet (Target): 220°C ✓ ║ │ │ ║ Actual Outlet: 219.8°C ║ │ │ ║ Rise (ΔT): 59.8°C ║ │ │ ║ ║ │ │ ║ Flue Gas In: 425°C ║ │ │ ║ Flue Gas Out: 155°C ║ │ │ ║ Flue Drop: 270°C ║ │ │ ║ Pinch Point: 425 − 220 = 205°C ✓ ║ │ │ ╚═════════════════════════════════════════╝ │ │ │ │ ╔═════════════ BYPASS VALVE STATUS ═════╗ │ │ ║ Command: ████░░░░░░░ 42% ║ │ │ ║ Feedback: ████░░░░░░░ 42% (✓) ║ │ │ ║ Flow Split: 42% bypass, 58% tubes ║ │ │ ╚═════════════════════════════════════════╝ │ │ │ │ ╔═════════ EFFICIENCY PERFORMANCE ════╗ │ │ ║ Heat Recovery: 25.2 MW ║ │ │ ║ Effectiveness: 78% (Good!) ║ │ │ ║ Load Adapted SP: 220°C (100% load) ║ │ │ ║ Efficiency Gain: +2.8% vs baseline ║ │ │ ╚════════════════════════════════════════╝ │ │ │ │ ⚠️ [NONE] 🔴 [NONE] │ │ │ │ Load: 100% | Trend: ▂▃▄▄▅ Stable │ │ │ └────────────────────────────────────────────────┘ ``` --- ## 🔧 Configuration Parameters ```json { "economizer_outlet_temp": { "description": "Feedwater preheat temperature control via bypass valve", "setpoint_full_load_celsius": 220.0, "setpoint_light_load_celsius": 215.0, "scan_time_sec": 2.0, "pid_tuning": { "proportional_gain_kp": 0.25, "integral_gain_ki": 0.012, "derivative_gain_kd": 0.001, "integral_limit_hi": 0.15, "integral_limit_lo": -0.10 }, "bypass_valve_limits": { "min_percent": 5.0, "max_percent": 95.0, "rate_limit_percent_per_sec": 1.5 }, "alarm_setpoints": { "temp_high_alarm_celsius": 230.0, "temp_low_alarm_celsius": 200.0, "pinch_point_min_celsius": 15.0, "effectiveness_threshold_percent": 60.0 }, "efficiency_monitoring": { "track_daily_heat_recovery_mw": true, "fouling_detection_effectiveness_drop_percent": 15.0 } } } ``` --- ## 📝 Implementation Checklist ### Commissioning (3 days) **Day 1: Baseline Calibration** - [ ] RTD temperatures verified: inlet, outlet, flue gas in/out (±2°C accuracy) - [ ] Bypass valve tested: manual operation 0–100% ✓ - [ ] Heat balance calculation: inlet + fuel energy = outlet + stack loss - [ ] Baseline effectiveness recorded at full load: ____ % **Day 2: Control Loop Commissioning** - [ ] PID engaged: observe outlet temperature hold at 220°C ±2°C - [ ] Load transient: 50% → 100% → observe smooth setpoint following - [ ] Bypass valve response: verify follows command within ±5% ✓ - [ ] No oscillation in temperature: peak-to-peak <±1°C ✓ **Day 3: Operational Validation** - [ ] 8-hour full-load run: temperature stable 220 ± 1°C ✓ - [ ] Heat recovery calculation: ____ MW (compare to design ____ MW) - [ ] Efficiency gain vs. bypass-closed baseline: ____ % - [ ] Fouling baseline captured for future trending --- ## 📊 Expected Performance (Full Load, Optimal Operation) | Parameter | Target | Range | Typical | |-----------|--------|-------|---------| | **Outlet Temperature** | 220°C | 218–222°C | **220.1°C** | | **Temperature Stability** | ±1°C | ± 2°C max | **±0.6°C** | | **Effectiveness** | > 75% | > 60% min | **78%** | | **Pinch Point** | > 20°C | > 15°C min | **25°C** | | **Bypass Valve Position** | 40–50% | 5–95% | **42%** | | **Heat Recovery** | ~25 MW | Scales with load | **25.2 MW** | | **Efficiency Gain** | 2.8% | 1.5–3.5% | **+2.8%** | --- ## 🔄 Advanced Variations ### Variation A: Feedwater Heater Staging Large plants use multiple economizer stages with separate control valves: - **Stage 1** (low-temp section): 160°C → 180°C inlet - **Stage 2** (mid-temp section): 180°C → 200°C inlet - **Stage 3** (high-temp section): 200°C → 220°C inlet Each stage has independent bypass valve. ### Variation B: Water Chemistry Adaptive Control Adjust setpoint based on dissolved oxygen content (indicator of corrosion risk): - If O₂ > 10 µg/L: Lower SP to 215°C (cooler = less corrosion) - If O₂ < 5 µg/L: Raise SP to 225°C (leaner = more heat recovery) --- ## 📄 Document Version History | Version | Date | Author | Change | |---------|------|--------|--------| | 1.0 | 2026-04-13 | Claude | Initial template: Bypass proportional control + fouling detection | --- *This template is part of the TSIMEREZIVO Industrial Process Control Library.*

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library