Air/Fuel Ratio Trim Cascade Control — Control Design

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 59 views

# TSIMEREZIVO Template: Air/Fuel Ratio Trim Cascade Control **Category:** Power Plant | **Industry:** Thermal Power Generation | **Language:** Ladder / Structured Text --- ## 📋 Overview ### Purpose Fine-tune air/fuel ratio (lambda) for optimal combustion energy recovery while meeting NOₓ emissions limits. This is the **secondary loop extension** to Template 01 (Furnace Combustion Pressure), explicitly managing stoichiometric ratio and O₂ excess using continuous emissions monitoring (CEMS). ### Typical Application - **Coal/NG Steam Boiler:** 100–300 MWe - **Furnace Temperature:** 1200–1600°C (flamefront) - **Excess Air:** 2–5% O₂ in flue gas (stoichiometric = 0% excess) - **NOₓ Emissions Limit:** 200–400 mg/Nm³ (EPA 40 CFR Part 75) - **CO Emissions Limit:** < 100 ppm (incomplete combustion warning) - **Sulfur Capture:** SO₂ + calcium (limestone) → CaSO₄ (gypsum; slurry absorber) ### Critical Control Objective **PARADOX:** More O₂ (lean burn) = Better efficiency (less unburned CO) BUT Higher NOₓ (thermal NOₓ from *high* flame temperature at lean conditions). Conversely, rich burn = Lower NOₓ but incomplete combustion = CO spikes + energy loss. **Solution:** Dynamic optimization via feedback loop that targets: - **Minimum NOₓ** (meet EPA limit of 250 mg/Nm³ typical) - **Maximum Efficiency** (CO < 50 ppm; O₂ 3–4%) - **Rapid transient response** (within 5 sec of load change) --- ## 🎯 Control Philosophy ### Key Equations **Stoichiometric Air Requirement:** ``` For bituminous coal (typical): Air needed = 10.5 [kg air / kg fuel] For natural gas (methane): Air needed = 17.2 [kg air / kg fuel] Excess air = (O₂_flue / 0.21) × 100% = Empirical, depends on flue gas oxygen analyzer reading % Excess O₂ = (O₂_measured / theoretical_O₂) × 100% ≈ (O₂_flue − 0%) / 3.5% (typical reference at stoich.) ``` **Thermal NOₓ Production (Zeldovich Mechanism):** ``` d[NOₓ]/dt ∝ T⁴ × [N₂] × [O₂]^0.5 Where T = flame temperature (K) Doubling O₂ % → NOₓ increases ~10–40% (non-linear) Increasing T by 50 K → NOₓ doubles Control target: Keep T as LOW as possible while maintaining combustion stability. ``` **Combustion Efficiency:** ``` η_combustion = 100% − (CO + H₂ + CH₄ in flue) / theoretical heat ≈ 99.5–99.9% for well-tuned boiler < 98% if CO > 100 ppm (unburned fuel waste) ``` ### Control Architecture: **Nested Cascade Loops** ``` Load Change (MW) │ ┌────┴────┐ ▼ ▼ [Primary Loop] [Secondary Loop: A/F Trim] ╔═══════════╗ ╔═════════════╗ ║ Furnace ║ ║ O₂ Analyzer ║ ║ Pressure ║ ║ + CEMS ║ ║ Control ║ ──→ (NOₓ, CO) ║ ╚═════════╤═╝ ╚═════╤═══════╝ │ │ │ ▼ │ [NOₓ Optimizer] │ Adjusts O₂ setpoint │ │ ▼ ▼ [Master Fuel] [Master Air] ↓ ↓ Fuel Valve Air Damper/Fan Speed Primary loop: Furnace pressure = baseline control Secondary loop: O₂/NOₓ = fine-tuning Both feed the same valve actuators (proportional solenoids). ``` ### Tuning Philosophy **Loop Tuning:** Slow and deliberate because: 1. CEMS analyzer has 30–60 sec response delay (reaction time) 2. Combustion efficiency changes take 10–20 sec to propagate 3. Aggressive tuning causes oscillation ±15–20 ppm NOₓ **Target Response:** - O₂ setpoint change → 60 sec to stabilize NOₓ within ±10 ppm - No overshoot (target: smooth ramp) --- ## 🏗️ Control Logic ### Pseudocode: Air/Fuel Ratio Trim Cascade (Secondary Loop Only) ```pascal PROGRAM AirFuelRatioTrimControl; { ========== DECLARATIONS ========== } VAR -- PRIMARY LOOP SIGNALS (from Template 01) furnace_pressure_actual : REAL; { From pressure sensor } furnace_pressure_sp : REAL; { From primary loop PID } fuel_flow_actual : REAL; { kg/s } -- SECONDARY LOOP SENSORS (THIS PROGRAM) o2_flue_analyzer : REAL; { 0-20 % O₂ in flue gas } nox_emissions_ppm : REAL; { 0-500 ppm, CEMS instrument } co_emissions_ppm : REAL; { 0-200 ppm, CEMS instrument } so2_emissions_ppm : REAL; { 0-200 ppm, optional } flue_gas_temp : REAL; { 100-200 °C, thermocouple } -- ANALYZER HEALTH analyzer_valid : BOOL; { Data valid flag from CEMS } analyzer_response_delay : REAL := 45.0; { Sec until stabilized } -- CONTROL SETPOINTS o2_sp_optimal : REAL := 3.5; { Target O₂ % (stoichiometric balance) } nox_sp_limit : REAL := 250.0; { EPA or plant permit limit [ppm] } co_sp_high_alarm : REAL := 100.0; { Incomplete combustion alarm } -- TRIM CORRECTION LOGIC o2_error : REAL; nox_error : REAL; nox_excess_above_limit : REAL; -- PROPORTIONAL TRIM TERM kp_o2_trim : REAL := 0.15; { Slow: O₂ is sensitive parameter } kp_nox_optimization : REAL := 0.05; { Even slower: NOₓ is highly non-linear } -- TRIM OUTPUT (Commands to primary loop) o2_sp_trim_adjustment : REAL := 0.0; { Offset added to O₂ setpoint } fuel_flow_offset : REAL := 0.0; { Alternative: direct fuel trim } -- DAMPING / STABILITY nox_moving_avg_60sec : REAL; { 60-sec rolling average filter } nox_rate_of_change : REAL; overshoot_protection : BOOL; -- PERFORMANCE TRACKING efficiency_index : REAL; nox_compliance_margin : REAL; analyzer_fault_count : INT := 0; BEGIN { ========== SENSOR INPUT & VALIDATION ========== } -- Check CEMS analyzer health (signal validity flag from instrument) IF NOT analyzer_valid THEN analyzer_fault_count := analyzer_fault_count + 1; IF analyzer_fault_count > 10 THEN { > 10 invalid readings in a row } { ALARM: "CEMS analyzer fault or drift — O₂ trim disabled, operating on O₂ only" } { Fall back to primary pressure loop (Template 01) } RETURN; { Exit this trim program; primary loop continues } END_IF; ELSE analyzer_fault_count := 0; END_IF; -- Apply 60-second moving average to NOₓ (filter noise) nox_moving_avg_60sec := (nox_moving_avg_60sec × 0.95) + (nox_emissions_ppm × 0.05); { ========== ERROR CALCULATIONS ========== } -- O₂ error (primary) o2_error := o2_sp_optimal - o2_flue_analyzer; -- NOₓ error (secondary) nox_excess_above_limit := nox_moving_avg_60sec - nox_sp_limit; nox_error := 0.0; { Even if at target, may need lean for efficiency } { ========== DECISION TREE: A/F TRIM LOGIC ========== } -- CASE 1: NOₓ Exceeding Limit (Lean Condition = Too Much O₂) IF nox_moving_avg_60sec > nox_sp_limit THEN -- PROBLEM: O₂ is TOO HIGH → Flame too hot → NOₓ spike -- SOLUTION: REDUCE O₂ setpoint → richer burn → cooler flame → lower NOₓ nox_error := nox_excess_above_limit; o2_sp_trim_adjustment := -kp_nox_optimization × nox_error; { Example: If NOₓ = 280 ppm (excess of 30 ppm): Trim = -0.05 × 30 = -1.5 New O₂ SP = 3.5 − 1.5 = 2.0% (richer, less air) Expected: Cooler combustion → NOₓ drops } -- CASE 2: CO Rising (Rich Condition = Too Little O₂) ELSIF co_emissions_ppm > co_sp_high_alarm THEN -- PROBLEM: Not enough air → incomplete combustion → CO rises -- SOLUTION: INCREASE O₂ setpoint → leaner → better flame contact → CO drops co_error := co_emissions_ppm - co_sp_high_alarm; o2_sp_trim_adjustment := +kp_o2_trim × (co_error / 100.0); { Normalize to 100 ppm range } { Example: If CO = 150 ppm (50 ppm over limit): Trim = +0.15 × (50/100) = +0.075 New O₂ SP = 3.5 + 0.075 = 3.575% (leaner, more air) Expected: Better air/fuel mixing → CO drops } -- CASE 3: Optimal Range (NOₓ < Limit AND CO < 100 ppm) ELSE -- MAINTAIN: Gradually optimize for maximum efficiency -- Keep O₂ as close to stoichiometric (0% excess) as possible without hitting NOₓ or CO limits IF nox_moving_avg_60sec < (nox_sp_limit − 30.0) THEN -- Extra margin to limit: can go LEANER to save more fuel o2_sp_trim_adjustment := o2_sp_trim_adjustment + 0.1; { Slowly increase O₂ } ELSIF nox_moving_avg_60sec > (nox_sp_limit − 10.0) THEN -- Close to limit: stay RICHER to maintain safety margin o2_sp_trim_adjustment := o2_sp_trim_adjustment − 0.05; { Slowly decrease O₂ } ELSE -- Dead-band: maintain current trim o2_sp_trim_adjustment := o2_sp_trim_adjustment × 0.99; { Very slight decay if drifting } END_IF; END_IF; { ========== RATE LIMITING (Anti-Shock) ========== } -- Prevent sudden O₂ setpoint swings -- Max change: ±0.3 per scan (2-sec scans → ±0.15/sec) IF o2_sp_trim_adjustment > o2_sp_trim_adjustment_prev + 0.3 THEN o2_sp_trim_adjustment := o2_sp_trim_adjustment_prev + 0.3; ELSIF o2_sp_trim_adjustment < o2_sp_trim_adjustment_prev − 0.3 THEN o2_sp_trim_adjustment := o2_sp_trim_adjustment_prev − 0.3; END_IF; { ========== OVERSHOOT PROTECTION ========== } -- If NOₓ dropped >20 ppm in last 2 minutes → we went too rich → back off slightly nox_rate_of_change := (nox_moving_avg_60sec − nox_prev) / scan_time; IF nox_rate_of_change < -20.0 AND scan_counter > 120 THEN { Past overshoot; becoming too rich now } o2_sp_trim_adjustment := MIN(o2_sp_trim_adjustment + 0.2, 0.0); { Lean back out slightly } overshoot_protection := TRUE; ELSE overshoot_protection := FALSE; END_IF; { ========== CONSTRAINTS ========== } -- Keep trim within reasonable bounds IF o2_sp_trim_adjustment > 1.5 THEN o2_sp_trim_adjustment := 1.5; { Max lean: 3.5 + 1.5 = 5.0% O₂ } ELSIF o2_sp_trim_adjustment < -2.0 THEN o2_sp_trim_adjustment := -2.0; { Max rich: 3.5 − 2.0 = 1.5% O₂ (combustion danger!) } END_IF; { ========== COMBINED O₂ SETPOINT ========== } -- Primary loop (Template 01) maintains furnace pressure -- Secondary loop (this) applies O₂ trim offset o2_setpoint_final := o2_sp_optimal + o2_sp_trim_adjustment; -- This final setpoint is sent to PRIMARY LOOP as its O₂ feedback target -- Primary loop's secondary (O₂ trim) loop will use this as reference { ========== EFFICIENCY TRACKING ========== } -- Calculate combustion efficiency index IF co_emissions_ppm < 50.0 AND nox_moving_avg_60sec < (nox_sp_limit − 20.0) THEN efficiency_index := 100.0; { Optimal zone } ELSIF co_emissions_ppm < 100.0 AND nox_moving_avg_60sec < nox_sp_limit THEN efficiency_index := 95.0; { Good } ELSIF co_emissions_ppm > 150.0 OR nox_moving_avg_60sec > (nox_sp_limit + 50.0) THEN efficiency_index := 80.0; { Poor; loss of combustion control } ELSE efficiency_index := 90.0; { Acceptable } END_IF; -- NOₓ compliance margin (how far below limit?) nox_compliance_margin := nox_sp_limit − nox_moving_avg_60sec; { ========== ALARMS ========== } IF nox_moving_avg_60sec > nox_sp_limit + 50.0 THEN { CRITICAL: "NOₓ emissions EXCEEDING PERMIT by 50 ppm — manual control required" } END_IF; IF co_emissions_ppm > 200.0 THEN { CRITICAL: "CO extremely high (>200 ppm) — incomplete combustion; reduce load immediately" } END_IF; IF analyzer_fault_count > 5 THEN { ALARM: "CEMS analyzer unstable — trim control suspended; operating on primary loop only" } END_IF; IF overshoot_protection THEN { INFO: "Overshoot protection active — backing off O₂ trim to prevent rich swing" } END_IF; { ========== SEND COMMAND TO PRIMARY LOOP ========== } -- Output: o2_setpoint_final (used as reference in Template 01's secondary loop) { ========== UPDATE STATE FOR NEXT CYCLE ========== } nox_prev := nox_moving_avg_60sec; o2_sp_trim_adjustment_prev := o2_sp_trim_adjustment; scan_counter := scan_counter + 1; END_PROGRAM; ``` --- ## 🏷️ Tag List ### Analog Inputs (Sensors) | Tag Name | Type | Range | Units | Description | |----------|------|-------|-------|-------------| | `O2_FLUE_ANALYZER` | AI | 0–20 | % | Flue gas O₂ concentration (CEMS) | | `NOX_EMISSIONS_CEMS` | AI | 0–500 | ppm | NOₓ (NO + NO₂) from continuous monitor | | `CO_EMISSIONS_CEMS` | AI | 0–200 | ppm | Carbon monoxide level | | `SO2_EMISSIONS_CEMS` | AI | 0–200 | ppm | Sulfur dioxide (optional, for SO₂ scrubber trim) | | `FLUE_GAS_TEMP` | AI | 0–300 | °C | Flue gas temperature (before air preheater) | | `ANALYZER_STATUS_FLAG` | DI | High = Valid | — | CEMS data validity signal | ### Analog Outputs | Tag Name | Type | Range | Units | Description | |----------|------|-------|-------|-------------| | `O2_SETPOINT_FINAL` | REAL | 1.5–5.0 | % | Final O₂ setpoint (sent to primary loop) | | `O2_TRIM_OFFSET` | REAL | −2.0 to +1.5 | % | Trim adjustment from secondary loop only | | `NOX_EFFICIENCY_INDEX` | REAL | 0–100 | — | Performance metric (100 = optimal control) | | `NOX_COMPLIANCE_MARGIN` | REAL | −50 to +250 | ppm | Distance below permit limit | ### Discrete Signals | Tag Name | Type | Logic | Description | |----------|------|-------|--|--- | `NOX_EXCEEDS_LIMIT` | DO | Latched | NOₓ > permit limit (250 ppm) | | `CO_HIGH_ALARM` | DO | Latched | CO > 100 ppm (incomplete combustion) | | `CEMS_ANALYZER_FAULT` | DO | Latched | >5 invalid readings; trim disabled | | `OVERSHOOT_PROTECTION` | DO | Pulse | Trim backing off due to overshoot | --- ## 🚨 Alarm & Trip Matrix | Condition | Threshold | Severity | Action | Recovery | |-----------|-----------|----------|--------|----------| | **NOₓ Over Permit** | > 250 ppm | 🔴 TRIP | Reduce load 5-10%; richen mixture | < 240 ppm | | **NOₓ Critical** | > 300 ppm | 🔴 CRIT | Reduce load to 50%; manual control | Investigate combustion | | **CO High** | > 100 ppm | ⚠️ WARN | Lean out (more air); check mixing | < 50 ppm | | **CO Critical** | > 200 ppm | 🔴 CRIT | Stop combustion immediately | Restart from cold | | **CEMS Fault** | Invalid data >5 readings | ⚠️ WARN | Disable trim; use pressure control only | CEMS repair/recalibration | | **O₂ Oscillating** | ±1 % in 30 sec | ⚠️ WARN | Trim tuning unstable; reduce Kp | Re-tune | --- ## 📺 HMI Layout ### Air/Fuel Ratio Trim Status Panel ``` ┌────────────────────────────────────────────────┐ │ A/F RATIO TRIM & EMISSIONS MONITOR │ ├────────────────────────────────────────────────┤ │ │ │ ╔════════════════ CEMS DATA ═════════════╗ │ │ ║ O₂ Flue: 3.4% (SP: 3.5%) ║ │ │ ║ NOₓ: 242 ppm (Limit: 250) ║ │ │ ║ CO: 32 ppm (Alarm: 100) ║ │ │ ║ SO₂: 45 ppm (Info only) ║ │ │ ║ Flue Temp: 165°C ║ │ │ ║ ║ │ │ ║ Analyzer Status: ✓ Valid (45 sec age) ║ │ │ ╚══════════════════════════════════════════╝ │ │ │ │ ╔═════════ CONTROL TRIM STATE ═════════╗ │ │ ║ O₂ Trim Offset: +0.2 % ║ │ │ ║ Final O₂ SP: 3.7% ✓ ║ │ │ ║ Trim Direction: LEANING (more air) ║ │ │ ║ Stability: Good ✓ ║ │ │ ║ Overshoot Protect: Inactive ║ │ │ ╚═════════════════════════════════════╝ │ │ │ │ ╔══════════ PERFORMANCE ════════════╗ │ │ ║ Eff Index: 98/100 GoodJ ║ │ │ ║ NOₓ Margin: +8 ppm (safe) ║ │ │ ║ Compliance Score: ✓✓✓ Excellent ║ │ │ ║ Recent Faults: [None] ║ │ │ ╚═════════════════════════════════════╝ │ │ │ │ ⚠️ [NONE] 🔴 [NONE] │ │ │ │ [Load: 75%] [Last Trim: 2 min ago] [Permit: EPA] │ │ └────────────────────────────────────────────────┘ ``` ### Trend Graph: O₂, NOₓ, CO Over 4 Hours ``` O₂ [%] 5 ├─ 4 ├─────╱╲ ╱╲──────────── 3 ├────╱ ╲───────╱ ╲────────── ← Setpoint 2 ├───╱────╲─────────╲────────── 1 └───────────────────────────── NOₓ [ppm] 350 ├─ 300 ├─╱╲ ╱╲───────────── 250 ├╱ ╲────────────╱ ╲────────── ← Permit limit 200 ├─────────────────────────────── 100 └─ CO [ppm] 150 ├─ ╱╲ ╱╲ 100 ├───╱ ╲───────╱ ╲────────── ← Alarm 50 ├────────╲─────────╲────────── 0 └───────────────────────────── └──00:00──01:00──02:00──03:00──04:00 Observations: - 00:00–01:00: O₂ = 3.4%, NOₓ = 242 (below limit), CO = 30 (excellent) - 01:00–02:00: Load ramp → O₂ trim adds +0.5 → O₂ = 3.9% (leaner = better efficiency) - 02:00–04:00: Stable at optimal trim; NOₓ stable below limit ``` --- ## 🔧 Configuration Parameters ```json { "air_fuel_ratio_trim": { "description": "Secondary loop A/F optimization (extends Template 01)", "o2_setpoint_optimal_percent": 3.5, "nox_permit_limit_ppm": 250.0, "co_high_alarm_ppm": 100.0, "scan_time_sec": 2.0, "cems_response_delay_sec": 45.0, "trim_tuning": { "proportional_gain_kp_o2": 0.15, "proportional_gain_kp_nox": 0.05, "integral_gain_ki": 0.0, "derivative_gain_kd": 0.0, "rate_limit_percent_per_scan": 0.3, "max_trim_lean_percent": 1.5, "max_trim_rich_percent": -2.0 }, "filtering": { "nox_moving_average_sec": 60.0, "nox_rate_change_threshold_ppm_per_min": -20.0, "overshoot_detection_window_sec": 120.0 }, "efficiency_zones": { "optimal_co_max_ppm": 50.0, "optimal_nox_margin_ppm": 20.0, "good_co_max_ppm": 100.0, "poor_nox_threshold_above_limit_ppm": 50.0 } } } ``` --- ## 📝 Implementation Checklist ### Instrumentation Pre-Install - [ ] CEMS analyzer system procured: O₂, NOₓ, CO, SO₂ capability - [ ] Sampling probe located: flue gas duct (after air preheater, before stack) - [ ] Analyzer warmup time confirmed: typically 30–45 minutes before valid data - [ ] Data communication: analyzer outputs via 4-20 mA or digital (Modbus/ethernet) - [ ] O₂ transmitter verified: high accuracy (<±0.5% O₂) - [ ] Flue gas temperature thermocouple installed: compensate density calculations ### Hot Commissioning (Plant at load, 5 days) **Day 1: Analyzer Validation** - [ ] CEMS online; compare O₂ reading vs. standalone portable analyzer - Portable: _____ % - CEMS: _____ % - Difference: < 0.5% ✓ - [ ] NOₓ reading stable after warmup (check baseline vs. permit) **Day 2: Primary Loop Baseline (No secondary trim active)** - [ ] Run with Template 01 only (no secondary A/F cascade) - [ ] Furnace pressure control active - [ ] Record: O₂ ___%, NOₓ ___ppm, CO ___ppm - [ ] Note if NOₓ is within permit (good starting point for trim tuning) **Day 3: Enable Secondary Trim; Observe Response** - [ ] Engage secondary trim loop (this program) - [ ] Monitor O₂ setpoint adjustment happening automatically - [ ] Observe NOₓ trend: should move toward permit limit ±10 ppm - [ ] Record trim offset direction: ___% (positive = leaning out) - [ ] Oscillation check: ±1-2% in O₂ acceptable; >2% means overtight tuning **Day 4: Load Transient Test** - [ ] Load step 50% → 100% - [ ] Monitor NOₓ response: should stabilize within 90–120 seconds - [ ] Peak NOₓ during transient: ___ppm (should not exceed limit + 30 ppm buffer) - [ ] CO during transient: ___ppm (should stay <150 ppm) **Day 5: Long-Term Stability (8-hour run)** - [ ] Run at constant full load - [ ] Monitor: NOₓ trend (should not drift), O₂ oscillation (should be <±0.5%) - [ ] Record 1-hour baseline snapshot for future comparison - [ ] Verify CEMS analyzer stability (no dropouts) - [ ] Confirm NO permit violations over 8 hours ✓ --- ## 📊 Expected Performance ### Steady-State (Full Load, Optimal Trim) | Parameter | Target | Range | Typical | |-----------|--------|-------|---------| | **O₂ Flue** | 3.5% | 3.0–4.0% | **3.4%** | | **NOₓ Emissions** | <200 ppm | <250 ppm limit | **242 ppm** | | **CO Emissions** | <50 ppm | <100 ppm | **32 ppm** | | **SO₂ Emissions** | <50 ppm | <200 ppm | **45 ppm** | | **Flue Temp** | 160–170°C | — | **165°C** | | **Trim Offset** | ±0.3% | ±2.0% max | **+0.2%** | | **Efficiency Index** | 98–100 | >90 | **98** | ### Transient Response (Load 50% → 100%) | Time (sec) | Load (%) | O₂ (%) | NOₓ (ppm) | CO (ppm) | Trend | |-----------|----------|--------|----------|----------|-------| | 0 | 50 | 3.4 | 220 | 28 | Baseline | | 30 | 75 | 3.5 | 245 | 35 | Lean due to load | | 60 | 100 | 3.7 | 265 | 42 | Peak NOₓ (above ideal, within limit) | | 90 | 100 | 3.5 | 250 | 38 | Trim correcting back | | 120 | 100 | 3.4 | 242 | 32 | **Settled** ✓ | --- ## 🔄 Advanced Variations ### Variation A: Automatic Permit Compliance Setpoint If plant operates in multiple compliance regimes (summer/winter NOₓ levels differ): ``` IF Month BETWEEN May AND September THEN nox_sp_limit := 200 ppm { More stringent summer } ELSE nox_sp_limit := 250 ppm { Standard winter } END_IF ``` ### Variation B: Load-Dependent O₂ Scheduling Some plants optimize O₂ differently based on load: ``` O₂_optimal = 3.5 + 0.05 × (100 − Load) = 3.5 at full load, 8.0 at 0% load (combustion stability concern) ``` --- ## 📄 Document Version History | Version | Date | Author | Change | |---------|------|--------|--------| | 1.0 | 2026-04-13 | Claude | Initial template: NOₓ trim + CEMS feedback | --- *This template is part of the TSIMEREZIVO Industrial Process Control Library.*

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library