Field fix / guidePLC / HMI Code & LogicVendor-agnostic (IEC 61131-3)Safetyindustrial-automation

Press Machine Two Hand — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 38 views

# Press Machine Two Hand — Usage Guide ## Overview SIL2-oriented press control template with anti-tie-down, simultaneity window, light-curtain trip, guard interlock, and STO output. ## Safety Notes - This software pattern supplements, not replaces, a certified safety relay or safety PLC design - Palm buttons must be monitored for weld and tie-down faults - STO output should de-energize drive torque through a certified safety path ## Commissioning 1. Verify simultaneity window with test actuator timing 2. Confirm any light-curtain interruption forces STO immediately 3. Test manual reset only works when hazard is cleared and press is at top position --- ## Control Logic — Vendor-Agnostic Pseudocode # Press Machine Two Hand — Logic ## Standards: IEC 61131-3 | ISO 13849 | IEC 61508 SIL2 ## Scan Rate: 5ms | Pattern: two-hand control with anti-tie-down, light curtain, STO ``` ROUTINE: PressMachineTwoHand SCAN_RATE: 5ms // SECTION 1 — SAFETY INPUT VALIDATION PB_LEFT_EDGE := PB_LEFT AND NOT PB_LEFT_PREV PB_RIGHT_EDGE := PB_RIGHT AND NOT PB_RIGHT_PREV PB_LEFT_PREV := PB_LEFT PB_RIGHT_PREV := PB_RIGHT SIMULT_WINDOW_OK := ABS(PB_LEFT_TS - PB_RIGHT_TS) <= TWO_HAND_WINDOW_TICKS ANTI_TIE_DOWN_OK := NOT PB_LEFT_HELD AND NOT PB_RIGHT_HELD SAFE_ZONE_OK := NOT LIGHT_CURTAIN_BLOCKED AND GUARD_CLOSED AND NOT ESTOP_ACTIVE // SECTION 2 — STROKE AUTHORISATION IF PB_LEFT_EDGE THEN PB_LEFT_TS := SYS_TICK END_IF IF PB_RIGHT_EDGE THEN PB_RIGHT_TS := SYS_TICK END_IF PRESS_PERMIT := PB_LEFT AND PB_RIGHT AND SIMULT_WINDOW_OK AND ANTI_TIE_DOWN_OK AND SAFE_ZONE_OK AND RESET_DONE // SECTION 3 — PRESS CYCLE IF PRESS_PERMIT AND NOT PRESS_CYCLE_ACTIVE THEN CLUTCH_CMD := TRUE BRAKE_RELEASE_CMD := TRUE PRESS_CYCLE_ACTIVE := TRUE STROKE_TMR := 0 END_IF IF PRESS_CYCLE_ACTIVE THEN STROKE_TMR := STROKE_TMR + 1 IF TOP_POS_FB AND STROKE_TMR > MIN_STROKE_TICKS THEN CLUTCH_CMD := FALSE BRAKE_RELEASE_CMD := FALSE PRESS_CYCLE_ACTIVE := FALSE END_IF END_IF // SECTION 4 — SAFETY TRIPS IF LIGHT_CURTAIN_BLOCKED OR ESTOP_ACTIVE OR NOT GUARD_CLOSED THEN STO_CMD := TRUE CLUTCH_CMD := FALSE BRAKE_RELEASE_CMD := FALSE PRESS_CYCLE_ACTIVE := FALSE SAFETY_TRIP := TRUE END_IF IF RESET_CMD AND SAFE_ZONE_OK AND TOP_POS_FB THEN SAFETY_TRIP := FALSE STO_CMD := FALSE RESET_DONE := TRUE END_IF // SECTION 5 — ALARMS IF SAFETY_TRIP THEN SET_ALARM(ALM_SAFETY_TRIP, CRITICAL) END_IF IF NOT SIMULT_WINDOW_OK AND PB_LEFT AND PB_RIGHT THEN SET_ALARM(ALM_TWO_HAND_FAULT, HIGH) END_IF // SECTION 6 — HMI HMI_PRESS_ACTIVE := PRESS_CYCLE_ACTIVE HMI_SAFETY_TRIP := SAFETY_TRIP HMI_STO := STO_CMD END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address PB_LEFT,Left Palm Button,BOOL,input,,,,FALSE,DI:0:0.0 PB_RIGHT,Right Palm Button,BOOL,input,,,,FALSE,DI:0:0.1 PB_LEFT_PREV,Previous Left Palm State,BOOL,internal,,,,FALSE, PB_RIGHT_PREV,Previous Right Palm State,BOOL,internal,,,,FALSE, PB_LEFT_EDGE,Left Palm Rising Edge,BOOL,calculated,,,,FALSE, PB_RIGHT_EDGE,Right Palm Rising Edge,BOOL,calculated,,,,FALSE, PB_LEFT_TS,Left Palm Timestamp,INT,internal,,0,999999,0, PB_RIGHT_TS,Right Palm Timestamp,INT,internal,,0,999999,0, SYS_TICK,System Tick Counter,INT,input,,0,999999,0, TWO_HAND_WINDOW_TICKS,Allowed Simultaneity Window (5ms ticks),INT,internal,,0,100,10, PB_LEFT_HELD,Left Palm Welded/Held Input Diagnostic,BOOL,input,,,,FALSE,DI:0:0.2 PB_RIGHT_HELD,Right Palm Welded/Held Input Diagnostic,BOOL,input,,,,FALSE,DI:0:0.3 SIMULT_WINDOW_OK,Two Hand Window OK,BOOL,calculated,,,,FALSE, ANTI_TIE_DOWN_OK,Anti-Tie-Down Valid,BOOL,calculated,,,,FALSE, LIGHT_CURTAIN_BLOCKED,Light Curtain Interrupted,BOOL,input,,,,FALSE,DI:0:0.4 GUARD_CLOSED,Guard Closed Interlock,BOOL,input,,,,TRUE,DI:0:0.5 ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.6 SAFE_ZONE_OK,Safe Zone Permissive,BOOL,calculated,,,,FALSE, RESET_CMD,Manual Safety Reset,BOOL,input,,,,FALSE, RESET_DONE,Reset Performed and Safe,BOOL,internal,,,,FALSE, TOP_POS_FB,Press Top Position Feedback,BOOL,input,,,,TRUE,DI:0:0.7 PRESS_PERMIT,Press Stroke Permit,BOOL,calculated,,,,FALSE, PRESS_CYCLE_ACTIVE,Press Cycle Active,BOOL,internal,,,,FALSE, STROKE_TMR,Stroke Timer,INT,internal,,0,10000,0, MIN_STROKE_TICKS,Minimum Stroke Time,INT,internal,,0,10000,50, CLUTCH_CMD,Clutch Command,BOOL,output,,,,FALSE,DO:1:0.0 BRAKE_RELEASE_CMD,Brake Release Command,BOOL,output,,,,FALSE,DO:1:0.1 STO_CMD,Safe Torque Off Command,BOOL,output,,,,FALSE,DO:1:0.2 SAFETY_TRIP,Safety Trip Latched,BOOL,internal,,,,FALSE, ALM_SAFETY_TRIP,Safety Trip Alarm,BOOL,calculated,,,,FALSE, ALM_TWO_HAND_FAULT,Two-Hand Timing Fault Alarm,BOOL,calculated,,,,FALSE, HMI_PRESS_ACTIVE,HMI: Press Cycle Active,BOOL,output,,,,FALSE, HMI_SAFETY_TRIP,HMI: Safety Trip,BOOL,output,,,,FALSE, HMI_STO,HMI: STO Command,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_SAFETY_TRIP,SAFETY_TRIP = TRUE,N/A,critical,safety,Safety trip latched. STO asserted. Clear hazard and perform manual reset from safe position.,0s,No ALM_TWO_HAND_FAULT,PB_LEFT and PB_RIGHT outside simultaneity window,<=50ms,high,safety,Invalid two-hand actuation. Check operator technique or input timing circuit.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library