Press Machine Two Hand — PLC Control Template
Shared by TSIMEREZIVO Team · 4 Oct 2026 · 38 views
# Press Machine Two Hand — Usage Guide
## Overview
SIL2-oriented press control template with anti-tie-down, simultaneity window, light-curtain trip, guard interlock, and STO output.
## Safety Notes
- This software pattern supplements, not replaces, a certified safety relay or safety PLC design
- Palm buttons must be monitored for weld and tie-down faults
- STO output should de-energize drive torque through a certified safety path
## Commissioning
1. Verify simultaneity window with test actuator timing
2. Confirm any light-curtain interruption forces STO immediately
3. Test manual reset only works when hazard is cleared and press is at top position
---
## Control Logic — Vendor-Agnostic Pseudocode
# Press Machine Two Hand — Logic
## Standards: IEC 61131-3 | ISO 13849 | IEC 61508 SIL2
## Scan Rate: 5ms | Pattern: two-hand control with anti-tie-down, light curtain, STO
```
ROUTINE: PressMachineTwoHand
SCAN_RATE: 5ms
// SECTION 1 — SAFETY INPUT VALIDATION
PB_LEFT_EDGE := PB_LEFT AND NOT PB_LEFT_PREV
PB_RIGHT_EDGE := PB_RIGHT AND NOT PB_RIGHT_PREV
PB_LEFT_PREV := PB_LEFT
PB_RIGHT_PREV := PB_RIGHT
SIMULT_WINDOW_OK := ABS(PB_LEFT_TS - PB_RIGHT_TS) <= TWO_HAND_WINDOW_TICKS
ANTI_TIE_DOWN_OK := NOT PB_LEFT_HELD AND NOT PB_RIGHT_HELD
SAFE_ZONE_OK := NOT LIGHT_CURTAIN_BLOCKED AND GUARD_CLOSED AND NOT ESTOP_ACTIVE
// SECTION 2 — STROKE AUTHORISATION
IF PB_LEFT_EDGE THEN PB_LEFT_TS := SYS_TICK END_IF
IF PB_RIGHT_EDGE THEN PB_RIGHT_TS := SYS_TICK END_IF
PRESS_PERMIT := PB_LEFT AND PB_RIGHT AND SIMULT_WINDOW_OK AND ANTI_TIE_DOWN_OK AND SAFE_ZONE_OK AND RESET_DONE
// SECTION 3 — PRESS CYCLE
IF PRESS_PERMIT AND NOT PRESS_CYCLE_ACTIVE THEN
CLUTCH_CMD := TRUE
BRAKE_RELEASE_CMD := TRUE
PRESS_CYCLE_ACTIVE := TRUE
STROKE_TMR := 0
END_IF
IF PRESS_CYCLE_ACTIVE THEN
STROKE_TMR := STROKE_TMR + 1
IF TOP_POS_FB AND STROKE_TMR > MIN_STROKE_TICKS THEN
CLUTCH_CMD := FALSE
BRAKE_RELEASE_CMD := FALSE
PRESS_CYCLE_ACTIVE := FALSE
END_IF
END_IF
// SECTION 4 — SAFETY TRIPS
IF LIGHT_CURTAIN_BLOCKED OR ESTOP_ACTIVE OR NOT GUARD_CLOSED THEN
STO_CMD := TRUE
CLUTCH_CMD := FALSE
BRAKE_RELEASE_CMD := FALSE
PRESS_CYCLE_ACTIVE := FALSE
SAFETY_TRIP := TRUE
END_IF
IF RESET_CMD AND SAFE_ZONE_OK AND TOP_POS_FB THEN
SAFETY_TRIP := FALSE
STO_CMD := FALSE
RESET_DONE := TRUE
END_IF
// SECTION 5 — ALARMS
IF SAFETY_TRIP THEN SET_ALARM(ALM_SAFETY_TRIP, CRITICAL) END_IF
IF NOT SIMULT_WINDOW_OK AND PB_LEFT AND PB_RIGHT THEN SET_ALARM(ALM_TWO_HAND_FAULT, HIGH) END_IF
// SECTION 6 — HMI
HMI_PRESS_ACTIVE := PRESS_CYCLE_ACTIVE
HMI_SAFETY_TRIP := SAFETY_TRIP
HMI_STO := STO_CMD
END_ROUTINE
```
---
## Tag List
```csv
Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address
PB_LEFT,Left Palm Button,BOOL,input,,,,FALSE,DI:0:0.0
PB_RIGHT,Right Palm Button,BOOL,input,,,,FALSE,DI:0:0.1
PB_LEFT_PREV,Previous Left Palm State,BOOL,internal,,,,FALSE,
PB_RIGHT_PREV,Previous Right Palm State,BOOL,internal,,,,FALSE,
PB_LEFT_EDGE,Left Palm Rising Edge,BOOL,calculated,,,,FALSE,
PB_RIGHT_EDGE,Right Palm Rising Edge,BOOL,calculated,,,,FALSE,
PB_LEFT_TS,Left Palm Timestamp,INT,internal,,0,999999,0,
PB_RIGHT_TS,Right Palm Timestamp,INT,internal,,0,999999,0,
SYS_TICK,System Tick Counter,INT,input,,0,999999,0,
TWO_HAND_WINDOW_TICKS,Allowed Simultaneity Window (5ms ticks),INT,internal,,0,100,10,
PB_LEFT_HELD,Left Palm Welded/Held Input Diagnostic,BOOL,input,,,,FALSE,DI:0:0.2
PB_RIGHT_HELD,Right Palm Welded/Held Input Diagnostic,BOOL,input,,,,FALSE,DI:0:0.3
SIMULT_WINDOW_OK,Two Hand Window OK,BOOL,calculated,,,,FALSE,
ANTI_TIE_DOWN_OK,Anti-Tie-Down Valid,BOOL,calculated,,,,FALSE,
LIGHT_CURTAIN_BLOCKED,Light Curtain Interrupted,BOOL,input,,,,FALSE,DI:0:0.4
GUARD_CLOSED,Guard Closed Interlock,BOOL,input,,,,TRUE,DI:0:0.5
ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.6
SAFE_ZONE_OK,Safe Zone Permissive,BOOL,calculated,,,,FALSE,
RESET_CMD,Manual Safety Reset,BOOL,input,,,,FALSE,
RESET_DONE,Reset Performed and Safe,BOOL,internal,,,,FALSE,
TOP_POS_FB,Press Top Position Feedback,BOOL,input,,,,TRUE,DI:0:0.7
PRESS_PERMIT,Press Stroke Permit,BOOL,calculated,,,,FALSE,
PRESS_CYCLE_ACTIVE,Press Cycle Active,BOOL,internal,,,,FALSE,
STROKE_TMR,Stroke Timer,INT,internal,,0,10000,0,
MIN_STROKE_TICKS,Minimum Stroke Time,INT,internal,,0,10000,50,
CLUTCH_CMD,Clutch Command,BOOL,output,,,,FALSE,DO:1:0.0
BRAKE_RELEASE_CMD,Brake Release Command,BOOL,output,,,,FALSE,DO:1:0.1
STO_CMD,Safe Torque Off Command,BOOL,output,,,,FALSE,DO:1:0.2
SAFETY_TRIP,Safety Trip Latched,BOOL,internal,,,,FALSE,
ALM_SAFETY_TRIP,Safety Trip Alarm,BOOL,calculated,,,,FALSE,
ALM_TWO_HAND_FAULT,Two-Hand Timing Fault Alarm,BOOL,calculated,,,,FALSE,
HMI_PRESS_ACTIVE,HMI: Press Cycle Active,BOOL,output,,,,FALSE,
HMI_SAFETY_TRIP,HMI: Safety Trip,BOOL,output,,,,FALSE,
HMI_STO,HMI: STO Command,BOOL,output,,,,FALSE,
```
---
## Alarm Matrix
```csv
Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge
ALM_SAFETY_TRIP,SAFETY_TRIP = TRUE,N/A,critical,safety,Safety trip latched. STO asserted. Clear hazard and perform manual reset from safe position.,0s,No
ALM_TWO_HAND_FAULT,PB_LEFT and PB_RIGHT outside simultaneity window,<=50ms,high,safety,Invalid two-hand actuation. Check operator technique or input timing circuit.,0s,No
```