Field fix / guideDesign DocumentVendor-agnostic (IEC 61131-3)Oil & Gasindustrial-automation

Gas Compression & Discharge Throttling — Control Design

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 40 views

# Oil & Gas Template: Gas Compression & Discharge Throttling ## 1. Overview **Purpose:** Operate centrifugal or reciprocating gas compressor to maintain pipeline discharge pressure (setpoint typically 800–1500 psia) while protecting equipment from surge (compressor pre-surge condition) and limiting discharge temperature. As downstream demand fluctuates throughout the day (peak load evening, minimum load 3 AM), compressor inlet flow varies; must modulate compressor capacity via recycle valve (internal bypass) or inlet guide vanes (IGV) to match demand without surge. **Industry Standards:** - API 617 (Centrifugal Compressors) - API 675 (Reciprocating Compressors) - ASME B31.8 (Gas Transmission & Distribution Piping) - ISO 10169 (Compressor Recirculation / Anti-surge systems) - NFPA 68 (Deflagration Prevention) **Critical Constraints:** - **Surge margin:** compressor must stay right of surge line map (Q vs. head); if Q drops below surge → unit goes unstable, mechanical damage - **Antisurge valve:** recycles a percentage of discharge gas back to suction to maintain minimum flow; opening controlled by pressure ratio feedback - **Suction pressure:** typically 50–200 psia (field separator outlet); temperature range 40–100°F (cold weather = higher density = lower volume) - **Discharge pressure:** regulated setpoint (800–1500 psia typical); cannot exceed equipment rating or relief valve opens - **Temperature rise:** ΔT = (T_discharge − T_suction) ∝ compression ratio; high compression → high temp → cooler duty - **Choke point:** if compressor throttles too much (low mass flow) → energy efficiency drops, heat generation high - **Recycle rate:** 5–15% typical during part-load; every % recycled = waste energy (must recompress same gas) **Relevant Physics:** - **Polytropic head:** $H = \frac{Z × R × T_s}{1-n} × (\frac{P_d}{P_s})^{(1-n)/n} - 1)$ (joules/kg; Z = compressibility factor) - **Surge line:** $Q_{surge} = k × H^{0.5}$ (empirical; k from manufacturer map; as pressure ratio rises, minimum allowable flow drops) - **Antisurge logic:** $\Delta P_{valve} ∝ (\frac{P_d}{P_s} − SP) × margin\_factor$ (proportional to pressure ratio deviation) - **Efficiency:** polytropic efficiency $\eta_p$ = ideal work / actual work; typically 75–85% for centrifugal; declines at surge --- ## 2. Control Philosophy **Challenge:** Pipeline demand variable 5:1 throughout day. Compressor surge line forces operation in a safe envelope (above line, below choke). Naive approaches fail: - Fixed discharge pressure setpoint + no antisurge → surge into wall during low-demand hours - Full recycle @ all times → waste energy - Solution: **pressure ratio feedback + surge margin tracking** ``` LAYER 1: Pressure Ratio Monitor Inputs: Discharge pressure (Pd), Suction pressure (Ps) Output: Pressure ratio = Pd / Ps Note: As Ps drops (cold morning) or Pd demanded rises, ratio increases → moves toward surge line LAYER 2: Antisurge Valve Control (Anti-surge Recirculation) Setpoint: Pressure ratio margin = 1.05 × Current_Ratio (5% safety margin) Logic: If ratio > margin → open recycle valve proportionally Effect: Reduces net export, increases suction recirculation → flow stays >surge point LAYER 3: Discharge Pressure Regulator (Main Control Loop) Setpoint: 1000 psia (typical) Feedback: Discharge pressure transmitter Output: Modulates main recirculation valve opening Note: Varies recycle % to maintain discharge pressure as demand changes LAYER 4: Temperature Protection If discharge T > 250°F → throttle inlet (reduce suction pressure) or open cooler bypass Prevents equipment damage, extends compressor life ``` --- ## 3. Control Logic (Condensed) ```pascal { === GAS COMPRESSOR ANTISURGE & DISCHARGE PRESSURE CONTROL === } PROCEDURE Gas_Compressor_Subsurface_Pressure_Control CONSTANTS DISCHARGE_PRESSURE_SETPOINT_PSIA = 1000 SUCTION_PRESSURE_MIN_SAFE = 50 { psia, prevents choke } PRESSURE_RATIO_SP = 15 { typical for centrifugal } SURGE_MARGIN_SAFETY_FACTOR = 1.05 { 5% above measured ratio } ANTISURGE_VALVE_CLOSED_PCT = 0 ANTISURGE_VALVE_OPEN_PCT = 100 TEMPERATURE_MAX_DISCHARGE_F = 250 COMPRESSOR_SPEED_MAX_RPM = 10000 VARIABLES discharge_pressure_psia : REAL suction_pressure_psia : REAL discharge_temperature_f : REAL discharge_gas_flow_mmcfpd : REAL { million cubic feet per day } pressure_ratio : REAL { Pd / Ps } pressure_ratio_setpoint : REAL { adaptive } pressure_ratio_error : REAL antisurge_valve_position_pct : REAL antisurge_valve_setpoint_pct : REAL compressor_speed_rpm : REAL compressor_speed_command_pct : REAL { 0–100% for variable-speed } surge_margin_current : REAL { distance from surge line } BEGIN discharge_pressure_psia = Read_Discharge_Pressure() suction_pressure_psia = Read_Suction_Pressure() discharge_temperature_f = Read_DISCHARGE_TEMPERATURE() discharge_gas_flow_mmcfpd = Read_GAS_FLOW() { === PRESSURE RATIO & SURGE ASSESSMENT === } pressure_ratio = discharge_pressure_psia / suction_pressure_psia { Estimate surge line for current compressor speed } { Simplified: surge_ratio = k / speed_factor; as speed ↑, surge ratio lowers } estimated_surge_ratio = 12 − (0.0015 × compressor_speed_rpm) { empirical } surge_margin_current = pressure_ratio − estimated_surge_ratio IF surge_margin_current < 0.5 THEN Log_Warning("APPROACHING_SURGE_LINE_OPEN_ANTISURGE") surge_detected = TRUE END IF { === ANTISURGE VALVE CONTROL (Recirculation) === } { Dynamic setpoint: always maintain 5% margin above current ratio } pressure_ratio_setpoint = pressure_ratio × SURGE_MARGIN_SAFETY_FACTOR { PID to modulate recirculation valve } pressure_ratio_error = pressure_ratio_setpoint − pressure_ratio pid_antisurge = KP_AS × pressure_ratio_error + KI_AS × Integral(error) { If ratio rising → open recycle to maintain flow above surge } antisurge_valve_setpoint_pct = 20 + (pid_antisurge × 50) antisurge_valve_setpoint_pct = LIMIT(antisurge_valve_setpoint_pct, 0, 100) Write_Antisurge_Valve(antisurge_valve_setpoint_pct) { Effect: as more gas recirculates, net export Q drops, but suction circulation ↑ } { Keeps compressor on stable side of surge line } { === DISCHARGE PRESSURE FEEDBACK (Main Control) === } discharge_error = DISCHARGE_PRESSURE_SETPOINT_PSIA − discharge_pressure_psia pid_discharge = KP_DP × discharge_error + KI_DP × Integral(error) { Output modulates main throttle valve (or IGV for variable-speed) } { More throttling → higher upstream backpressure → lower compressor inlet } main_throttle_valve_pct = 50 + (pid_discharge × 30) main_throttle_valve_pct = LIMIT(main_throttle_valve_pct, 0, 100) Write_Main_Throttle_Valve(main_throttle_valve_pct) { Alternative for variable-speed: adjust compressor RPM instead of throttle } IF Compressor_Is_Variable_Speed THEN compressor_speed_rpm_target = 5000 + (discharge_error × 50) compressor_speed_rpm_target = LIMIT(compressor_speed_rpm_target, 3000, 10000) Write_VFD_Compressor_Speed(compressor_speed_rpm_target) END IF { === TEMPERATURE PROTECTION === } IF discharge_temperature_f > TEMPERATURE_MAX_DISCHARGE_F THEN Log_Warning("DISCHARGE_TEMP_EXCEED_LIMIT_" + STR(discharge_temperature_f) + "_F") { Option 1: throttle inlet (reduce suction → lower compression ratio) } suction_throttle_valve_pct = 80 { restrict inlet } Write_Inlet_Throttle_Valve(suction_throttle_valve_pct) { Option 2: open cooler bypass (if intercooler present) } cooler_bypass_valve_pct = 50 Write_Cooler_Bypass_Valve(cooler_bypass_valve_pct) ELSE suction_throttle_valve_pct = 100 { fully open } cooler_bypass_valve_pct = 0 { full cooler duty } END IF { === LOGGING === } IF MOD(scan_count, 10) = 0 THEN { every 10 seconds } Log_Process_Data({ timestamp: Get_Timestamp(), discharge_psia: discharge_pressure_psia, suction_psia: suction_pressure_psia, pressure_ratio: pressure_ratio, antisurge_valve_pct: antisurge_valve_position_pct, discharge_temp_f: discharge_temperature_f, gas_flow_mmcfpd: discharge_gas_flow_mmcfpd, compressor_speed_rpm: compressor_speed_rpm, surge_margin: surge_margin_current }) END IF END PROCEDURE ``` --- ## 4. Tag List (Selected) ``` DISCHARGE_PRESSURE_PSIA { main control variable } DISCHARGE_PRESSURE_SETPOINT_PSIA { target } SUCTION_PRESSURE_PSIA { feedback for pressure ratio } PRESSURE_RATIO { Pd / Ps, surge indicator } SURGE_MARGIN_PERCENT { distance from surge line } ANTISURGE_VALVE_POSITION_PCT { recirculation valve } DISCHARGE_TEMPERATURE_F { protection setpoint } GAS_FLOW_MMCFPD { production rate } COMPRESSOR_SPEED_RPM { for variable-speed units } RECYCLE_RATE_PERCENT { % of flow recirculated } ``` --- ## 5. Alarm & Trip Matrix | **Condition** | **Severity** | **Action** | |---|---|---| | **Surge margin < 0** | 🔴 CRIT | Open antisurge to maximum; reduce demand | | **Discharge temp >250°F** | ⚠ WARN | Throttle inlet; check cooler | | **Discharge pressure > 1200 psia** | ⚠ WARN | Relief likely venting; reduce demand | | **Suction pressure < 50 psia** | ⚠ WARN | Feed line choking; check upstream | --- ## 6. Configuration **JSON (gas_compressor_config.json)** ```json { "compressor": { "type": "centrifugal_variable_speed", "design_flow_mmcfpd": 100, "discharge_pressure_setpoint_psia": 1000, "speed_rated_rpm": 8000 }, "antisurge": { "surge_margin_safety_factor": 1.05, "recirculation_valve_type": "proportional", "estimated_surge_ratio_base": 12 }, "pid_tuning": { "discharge_kp": 0.5, "discharge_ki": 0.05, "antisurge_kp": 1.0, "antisurge_ki": 0.1 }, "safety": { "temperature_max_f": 250, "pressure_max_psia": 1200, "suction_min_psia": 50 } } ``` --- **Document Version:** 1.0 **Last Updated:** 2026-04-13 **Status:** Ready for Production

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library