Field fix / guideDesign DocumentVendor-agnostic (IEC 61131-3)Manufacturingindustrial-automation

Conveyor Belt Speed & Load Control — Control Design

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 36 views

# Manufacturing Template: Conveyor Belt Speed & Load Control ## 1. Overview **Purpose:** Modular conveyor control with variable-frequency drive (VFD) motor, load sensing, anti-slip protection, and emergency stop interlocks. Common in packaging, food processing, automotive assembly, pharmaceutical manufacturing. Coordinates with upstream feeders and downstream equipment. **Industry Standards:** - ASME B20.1 (Safety Standard for Conveyors) - NFPA 70 / IEC 61800-1 (VFD electrical safety) - ISO 13849-1 (Machinery safety — control systems) - ISO 13850 (Emergency stop / E-stop) **Critical Constraints:** - **Anti-slip threshold:** Product must not accelerate >0.5 m/s² relative to belt (prevent spillage or damage) - **Load sensing:** Current-based load estimator; if current >85% rated, reduce speed or halt feed - **Emergency stop:** Must de-energize motor AND engage mechanical brake within 0.5 sec - **Jammed product detection:** If belt current spikes 150% of nominal, automatic reversal + alarm - **Mechanical brake:** Spring-applied, power-released; holds belt at standstill - **Belt speed range:** 0.1–2.0 m/s; typical setpoint 0.8–1.2 m/s **Relevant Physics:** - Motor torque: **τ = k_t × I_motor** (proportional to current; linear region <85% rated) - Belt tension: **T = (μ × m_load × g) / radius** (friction balances weight) - Slip condition: If acceleration > 0.5 m/s² and friction exhausted → slip occurs - Power dissipation: **P = τ × ω = V_motor × I_motor** (if P increases rapidly = jam) --- ## 2. Control Philosophy **Challenge:** A high-speed conveyor with inbound products must accelerate products smoothly (avoid spillage), detect overload conditions (prevent motor burnout), and respond to emergency stops instantly. Fixed-speed operation causes jams; variable speed creates control complexity. **Solution: Load-Adaptive VFD + Slip Detection** ``` Base Mode: Speed Regulation - Target speed setpoint: 1.0 m/s (operator selectable 0.1–2.0) - VFD ramp-up: +0.2 m/s per second (8 sec to reach full speed, prevents sudden jolts) - Proportional-only control: Kp=0.15 (slow, smooth response for mechanical inertia) - Feedback: Encoder speed (or tachometer); closed-loop maintains ±5% of setpoint Load Monitoring: - Measure motor current continuously - If I_motor > 85% I_rated → "High Load" warning; reduce speed 10% - If I_motor > 100% I_rated → "Overload" alarm; reduce speed 20% or stop - If I_motor spikes >150% in <2 sec → "Jam Detected"; reverse belt 0.5 sec then stop Anti-Slip Detection: - Compare product acceleration (vision or proximity sensor) to belt acceleration - If product lags belt by >0.2 m/s → slip condition; reduce speed 30% - Once grip resumed → gradually restore speed (ramp +0.1 m/s per sec) Emergency Stop: - E-stop signal → immediate VFD off (motor coast to stop via mechanical inertia) - Brake solenoid de-energizes → spring-applied brake grips belt - Stop time: typically 2–5 seconds (friction deceleration) - Recovery: operator acknowledges fault, restarts sequence Feed Coordination: - If "conveyor stopped" signal from upstream feeder, accept products but don't accelerate past 0.3 m/s - If "output backed up" signal from downstream, reduce speed 50% (prevent overflow) ``` **Why this works:** - Load-adaptive speed prevents motor burnout (most common failure mode) - Ramp rate limiting (<0.2 m/s²) prevents product spillage (measured acceptability threshold) - Slip detection via current monitoring catches bearing friction asymmetry early - Jam reversal releases stuck products; manual inspection occurs before restart --- ## 3. Control Logic **Pseudocode: Conveyor Master Control** ```pascal { === CONVEYOR BELT SPEED CONTROL === } { States: IDLE → RUNNING → OVERLOAD_FAULT / JAMMING / SLIP → IDLE } PROCEDURE Conveyor_Belt_Master CONSTANTS SPEED_SETPOINT_DEFAULT = 1.0 { m/s } RAMP_RATE_UP = 0.2 { m/s per second (0.2 m/s² accel) } RAMP_RATE_DOWN = 0.3 { m/s per second (0.3 m/s² decel) } SPEED_MIN = 0.1 { m/s, minimum practical speed } SPEED_MAX = 2.0 { m/s, maximum safe speed } LOAD_WARNING_THRESHOLD = 0.85 { 85% rated current } LOAD_CRITICAL_THRESHOLD = 1.00 { 100% rated current } JAM_DETECTION_THRESHOLD = 1.50 { 150% rated current spike } JAM_DETECTION_RISE_TIME = 2.0 { seconds for current rise } CURRENT_SMOOTHING_TIME = 5.0 { sec, moving average filter } SLIP_THRESHOLD = 0.2 { m/s product lag vs. belt } SLIP_SPEED_REDUCTION = 0.30 { 30% speed reduction on slip } SPEED_RECOVERY_RATE = 0.1 { m/s per sec recovery } ENCODER_COUNTS_PER_REV = 2048 { encoder resolution } BELT_CIRCUMFERENCE_M = 1.57 { π × 0.5m pulley radius } VARIABLES state : ENUMERATION { IDLE, STARTING, RUNNING, OVERLOAD, JAM_REVERSING, E_STOP } speed_setpoint : REAL { m/s, operator input or reduced by logic } speed_actual : REAL { m/s, measured from encoder } speed_command : REAL { m/s, target sent to VFD } motor_current : REAL { A, scaled 0–200A range } motor_current_filtered : REAL { A, moving average } current_rise_rate : REAL { A per second } load_warning_flag : BOOLEAN load_critical_flag : BOOLEAN jam_detected_flag : BOOLEAN slip_detected_flag : BOOLEAN cycle_timer : INTEGER { seconds } jam_reversal_timer : INTEGER vfd_frequency_cmd : REAL { Hz, 0–60 Hz for 60 Hz motor } brake_solenoid_cmd : INTEGER { 0/1 = engaged/released } BEGIN { === READ SENSORS === } encoder_pulses = Read_Encoder_DI() speed_actual = (encoder_pulses / ENCODER_COUNTS_PER_REV) × BELT_CIRCUMFERENCE_M / SCAN_INTERVAL_SEC motor_current = Read_Current_AI() × (200.0 / 4095.0) { scale 4095 ADC counts → 200A } { === FILTER CURRENT (moving average, 5-sec window) === } motor_current_filtered = 0.9 × motor_current_filtered + 0.1 × motor_current current_rise_rate = (motor_current - motor_current_filtered) / SCAN_INTERVAL_SEC { === LOAD MONITORING === } load_warning_flag := (motor_current_filtered > LOAD_WARNING_THRESHOLD × 200.0) load_critical_flag := (motor_current_filtered > LOAD_CRITICAL_THRESHOLD × 200.0) { === JAM DETECTION === } IF current_rise_rate > (JAM_DETECTION_THRESHOLD × 200.0 / JAM_DETECTION_RISE_TIME) THEN jam_detected_flag = TRUE ELSE jam_detected_flag = FALSE END IF { === SLIP DETECTION (if product presence sensor available) === } product_speed := Read_Product_Speed_From_Vision() { m/s } IF (speed_actual - product_speed) > SLIP_THRESHOLD THEN slip_detected_flag = TRUE ELSE slip_detected_flag = FALSE END IF { === STATE MACHINE === } SELECT state CASE IDLE: speed_command := 0.0 vfd_frequency_cmd := 0.0 brake_solenoid_cmd := 0 { brake engaged, belt locked } cycle_timer := 0 { Start sequence when operator presses START or upstream feeder signals } IF Conveyor_Start_Signal THEN speed_setpoint := SPEED_SETPOINT_DEFAULT state := STARTING Log_Event("CONVEYOR_START_REQUESTED") END IF CASE STARTING: { === Ramp-up phase === } IF speed_command < speed_setpoint THEN speed_command := speed_command + RAMP_RATE_UP × SCAN_INTERVAL_SEC speed_command := MIN(speed_command, speed_setpoint) END IF { Soft-start: activate brake solenoid (release mechanical brake) } brake_solenoid_cmd := 1 { === Load check during ramp === } IF load_critical_flag THEN speed_command := speed_command × 0.8 { reduce speed 20% } Log_Warning("LOAD_CRITICAL_DURING_RAMP") END IF { === Transition to RUNNING when close to setpoint === } IF ABS(speed_actual - speed_setpoint) < 0.05 THEN state := RUNNING Log_Event("CONVEYOR_RUNNING_AT_SPEED") END IF CASE RUNNING: { === Closed-loop speed control (proportional only) === } speed_error = speed_setpoint - speed_actual proportional_correction = Kp_run × speed_error { Kp=0.15 } speed_command = speed_command + proportional_correction × SCAN_INTERVAL_SEC speed_command := Clamp(speed_command, SPEED_MIN, speed_setpoint) brake_solenoid_cmd := 1 { brake solenoid energized (brake released) } { === Handle high load conditions === } IF load_critical_flag THEN speed_setpoint := speed_setpoint × 0.8 { reduce operator setpoint by 20% } Log_Warning("OVERLOAD_DETECTED", motor_current_filtered) state := OVERLOAD ELSIF load_warning_flag AND NOT load_warning_acknowledged THEN { Warning only; continue running } Log_Warning("HIGH_LOAD", motor_current_filtered) END IF { === Handle jam conditions === } IF jam_detected_flag THEN jam_detected_flag = TRUE state := JAM_REVERSING Log_Alarm("JAM_DETECTED_REVERSING") END IF { === Handle slip conditions === } IF slip_detected_flag THEN speed_setpoint := speed_setpoint × (1.0 - SLIP_SPEED_REDUCTION) slip_detected_flag = TRUE Log_Warning("SLIP_CONDITION_REDUCING_SPEED") ELSIF slip_detected_flag = FALSE AND speed_setpoint < SPEED_SETPOINT_DEFAULT THEN { Slip resolved; gradually restore speed } speed_setpoint := speed_setpoint + SPEED_RECOVERY_RATE × SCAN_INTERVAL_SEC speed_setpoint := MIN(speed_setpoint, SPEED_SETPOINT_DEFAULT) END IF { === Downstream backup handling === } IF Downstream_Backup_Signal THEN speed_setpoint := speed_setpoint × 0.5 { reduce 50% } END IF CASE OVERLOAD: { === Load shedding / halt sequence === } { Speed command ramps down to stop } IF speed_command > SPEED_MIN THEN speed_command := speed_command - RAMP_RATE_DOWN × SCAN_INTERVAL_SEC ELSE speed_command := 0.0 END IF { === Wait for load to clear === } cycle_timer := cycle_timer + 1 IF (NOT load_critical_flag) AND cycle_timer > 30 THEN { 30 sec wait } state := IDLE Log_Event("OVERLOAD_CLEARED_RETURNING_TO_IDLE") speed_setpoint := SPEED_SETPOINT_DEFAULT END IF CASE JAM_REVERSING: { === Reverse belt to release trapped product === } IF jam_reversal_timer < 5 THEN { 5 seconds of reverse } speed_command := -0.5 { reverse at 0.5 m/s } vfd_frequency_cmd := -25.0 { negative frequency for reverse } jam_reversal_timer := jam_reversal_timer + 1 ELSE { Reverse complete; stop and alert } speed_command := 0.0 vfd_frequency_cmd := 0.0 Log_Alarm("JAM_REVERSED_MANUAL_INSPECTION_REQUIRED") state := IDLE jam_reversal_timer := 0 END IF CASE E_STOP: { === Emergency stop override === } speed_command := 0.0 vfd_frequency_cmd := 0.0 brake_solenoid_cmd := 0 { de-energize solenoid; mechanical brake engages } { Coast-to-stop via mechanical friction } cycle_timer := cycle_timer + 1 IF speed_actual < 0.05 AND cycle_timer > 10 THEN state := IDLE Log_Event("E_STOP_COMPLETE_BELT_HALTED") END IF END SELECT { state } { === PRIORITY OVERRIDE: EMERGENCY STOP === } IF Emergency_Stop_Button_Pressed OR Fault_Trip_Signal THEN state := E_STOP speed_command := 0.0 vfd_frequency_cmd := 0.0 brake_solenoid_cmd := 0 Log_Alarm("EMERGENCY_STOP_ACTIVATED") END IF { === CONVERT SPEED TO VFD FREQUENCY === } { VFD: 0–60 Hz = 0–2 m/s } vfd_frequency_cmd := (speed_command / SPEED_MAX) × 60.0 vfd_frequency_cmd := Clamp(vfd_frequency_cmd, -30.0, 60.0) { === WRITE OUTPUTS === } Set_VFD_Frequency_Command(vfd_frequency_cmd) Set_Brake_Solenoid(brake_solenoid_cmd) { === DIAGNOSTICS / LOGGING === } IF cycle_timer MOD 60 = 0 THEN { every 60 scan cycles = 1 minute } Log_Diagnostic("SPEED_ACTUAL=" + STR(speed_actual) + " CURRENT=" + STR(motor_current_filtered)) END IF END PROCEDURE ``` **Key Tuning Constants:** ``` Proportional gain (Kp_run) = 0.15 → At ±0.1 m/s speed error, correction = 0.015 m/s per scan → Smooth response; no overshoot; settles in 5–10 scans (10–20 seconds) Ramp rate = 0.2 m/s per second = 0.2 m/s² → Product acceleration = 0.2 m/s² well below slip threshold (0.5 m/s²) → 8 seconds to reach 1.6 m/s from standstill (safe acceleration) Current filtering = 5-second moving average → Smooths noise from VFD switching (10 kHz PWM) → Allows legitimate current transients to pass through ``` --- ## 4. Tag List **Analog Inputs (Measurements)** ``` BELT_SPEED_ACTUAL { Encoder counts → m/s; 0–2 m/s range } MOTOR_CURRENT_DRAW { CT transformer, 0–200 A; scaled 4–20 mA } MOTOR_VOLTAGE_LINE { 3-phase line voltage monitor, 380–480V } MOTOR_TEMPERATURE { RTD on motor frame, 0–80°C } PRODUCT_SPEED_DETECTED { Vision or laser sensor, 0–2 m/s (if available) } BELT_TENSION_ESTIMATE { Calculated from motor current and load model } ``` **Analog Outputs (Commands)** ``` VFD_FREQUENCY_COMMAND { 0–60 Hz (or -30 to +60 for reverse) } BRAKE_SOLENOID_COMMAND { 0/1 = engaged/released } UPSTREAM_FEEDER_SPEED_REQUEST { 0–100%, feedback to feeder control } ``` **Digital Inputs** ``` CONVEYOR_START_SIGNAL { 0/1, start button or external system } CONVEYOR_STOP_SIGNAL { 0/1, stop button } EMERGENCY_STOP_BUTTON { 0/1, E-stop button (hardwired) } CONVEYOR_FAULT_RESET { 0/1, acknowledge and clear alarm } DOWNSTREAM_EQUIPMENT_BACKUP { 0/1, signal = slow/stop conveyor } UPSTREAM_FEEDER_READY { 0/1, ready to feed products } MECHANICAL_BRAKE_ENGAGED { 0/1 feedback, brake status } ``` **Calculated / Diagnostic Tags** ``` SPEED_ERROR { m/s, setpoint - actual } MOTOR_LOAD_PERCENT { 0–100%, current / rated } CURRENT_RISE_RATE { A/sec, for jam detection } STATE { IDLE / STARTING / RUNNING / OVERLOAD / JAM / E_STOP } LOAD_WARNING_FLAG { Boolean, I > 85% } LOAD_CRITICAL_FLAG { Boolean, I > 100% } JAM_DETECTED_FLAG { Boolean, current spike >150% } SLIP_CONDITION_FLAG { Boolean, product speed < belt speed } CYCLE_TIMER { seconds, time in current state } VFD_FREQUENCY_ACTUAL { Hz, feedback from VFD display } ENCODER_COUNTS_PER_SAMPLE { raw pulse count per scan } BELT_RUNTIME_HOURS { cumulative; maintenance tracking } ``` --- ## 5. Alarm & Trip Matrix | **Condition** | **Setpoint** | **Severity** | **Action** | **Recovery** | |---|---|---|---|---| | **Load Warning** | I > 85% rated | ⚠ WARN | Log, reduce speed 10% | Auto when I < 80% | | **Load Critical** | I > 100% rated | 🔴 CRIT | Ramp down, go to OVERLOAD | Operator clears load, 30sec wait | | **Jam Detected** | I spike >150% in <2 sec | 🔴 CRIT | Reverse belt 5 sec, halt | Manual inspection; restart required | | **Slip Detected** | Product lag >0.2 m/s | ⚠ WARN | Reduce speed 30%, log | Auto-recover when grip resumes | | **Motor Overtemp** | RTD >75°C | 🔴 CRIT | Stop conveyor, alert | Cool motor; resume after 10 min | | **E-Stop Activated** | Button pressed OR fault trip | 🔴 CRIT | Brake solenoid de-energize, stop | Manual reset + acknowledge | | **Brake Failure** | Solenoid current <100mA for 5 sec | 🔴 CRIT | Disable VFD, safety halt | Maintenance required | | **Encoder Fault** | Speed stuck constant >10 sec | ⚠ WARN | Set speed to SAFE (0.3 m/s) | Verify encoder connection | | **VFD Comm Loss** | No heartbeat >2 sec | 🔴 CRIT | E-stop equivalent (brake engage) | Restart VFD power | | **Downstream Backup** | Backup signal continuous >5 min | ⚠ WARN | Run at 50% speed | Operator resolves downstream | | **Voltage Sag** | 3-phase <360V for >5 sec | 🔴 CRIT | Stop and latch off | Wait for power recovery | --- ## 6. HMI Layout **Main Conveyor Control Screen** ``` ╔════════════════════════════════════════════════════════════════╗ ║ CONVEYOR BELT SPEED & LOAD CONTROL — LINE A PACKAGING ║ ╚════════════════════════════════════════════════════════════════╝ CURRENT STATE: [ RUNNING ] UPTIME: 14 hr 23 min RUNTIME: 1,247 hrs (total) ┌─────────────────────────────────────────────────────────────┐ │ SPEED CONTROL SETPOINT: 1.0 m/s │ │ │ │ ┌──────────────────────────────────────────────────────┐ │ │ │ 0.98 m/s (within ±0.05 m/s) │ │ │ │ 0─────●────2 m/s │ │ │ │ Load: 78% I_rated Motor: 156 A │ │ │ │ Ramp Rate: 0.2 m/s per sec [GREEN] │ │ │ └──────────────────────────────────────────────────────┘ │ │ │ │ LOAD MONITORING │ │ [████████░░░░░░░░░░░░] 78% of rated current (156 A / 200 A) │ │ │ │ ⚠ Above 85% threshold — Monitor closely │ │ ✓ No slip detected │ │ ✓ No jam detected │ │ │ │ BRAKE STATUS: [RELEASED] (solenoid energized) │ │ VFD FREQUENCY: 48.9 Hz (sends to 60 Hz motor) │ │ │ └─────────────────────────────────────────────────────────────┘ MOTOR HEALTH SYSTEM STATUS Temp: 62°C ✓ Upstream Ready: ✓ Voltage: 415V ✓ Downstream Backed: ✗ Phase Balance: OK ✓ E-Stop Clear: ✓ BUTTONS: [ Start ] [ Stop ] [ Speed ▼ / ▲ ] [ E-Stop ] [ Reset ] TREND (Last 30 min): ┌──────────────────────────────────────────────────┐ │ 200 A │ │ │ 150 A │ ╱────────────────────── │ │ 100 A │╱ │ │ 50 A │ │ │ 0 │──────────────────────────────────────── │ │ └──────────────────────────────────────────┘ │ 0 10 20 30 min │ └──────────────────────────────────────────────────┘ ``` **Speed Setpoint Adjustment (Operator Control)** ``` ╔════════════════════════════════════════════════════════════════╗ ║ SPEED SETPOINT ADJUSTMENT ║ ╠════════════════════════════════════════════════════════════════╣ │ │ │ Current Setpoint: 1.0 m/s │ │ │ │ New Setpoint: [0.8_] m/s { range 0.1 to 2.0 } │ │ │ │ Ramp Rate: 0.2 m/s per sec (fixed; cannot adjust) │ │ │ │ [ CONFIRM CHANGE ] [ CANCEL ] │ │ │ ╚════════════════════════════════════════════════════════════════╝ ``` --- ## 7. Configuration **JSON Configuration (conveyor_belt_config.json)** ```json { "conveyor": { "name": "Conveyor Belt A — Packaging Line", "belt_circumference_m": 1.57, "max_distance_m": 25.0, "nominal_speed_mps": 1.0, "max_speed_mps": 2.0, "min_speed_mps": 0.1, "ramp_up_rate_mps_per_sec": 0.2, "ramp_down_rate_mps_per_sec": 0.3, "scan_interval_ms": 200 }, "motor": { "type": "3-phase AC induction", "rated_power_kw": 7.5, "rated_current_a": 15.0, "rated_speed_rpm": 1800, "pole_pairs": 2, "vfd_frequency_range_hz": [0, 60], "soft_start": true, "brake_type": "spring_applied_power_released", "brake_engagement_time_sec": 0.5 }, "sensors": { "speed_encoder": { "type": "incremental_rotary", "counts_per_revolution": 2048, "pulley_circumference_m": 0.785, "di_channel": 0, "di_channel_quad": 1 }, "motor_current": { "type": "current_transformer_0_200a", "ai_channel": 0, "scaling": "linear", "filter_time_constant_sec": 5.0 }, "motor_temperature": { "type": "RTD_Pt100", "ai_channel": 1, "alarm_threshold_c": 75.0 }, "line_voltage_3phase": { "type": "voltage_monitor_0_480v", "ai_channel": 2, "low_voltage_threshold_v": 360 }, "product_presence_vision": { "type": "AI_camera_feed", "estimated_speed_mps": "via image_processing", "optional": true } }, "actuators": { "vfd_drive": { "type": "ABB_ACS380", "rated_output_current_a": 15.0, "ao_channel_frequency": 0, "communication_protocol": "Modbus_RTU", "baudrate_bps": 19200 }, "brake_solenoid": { "type": "24VDC_solenoid", "do_channel": 0, "engage_action": "de_energize", "release_action": "energize" } }, "control_parameters": { "speed_regulation": { "kp": 0.15, "ki": 0.0, "kd": 0.0, "proportional_band_percent": 10.0 }, "load_management": { "warning_threshold_percent_rated": 85, "critical_threshold_percent_rated": 100, "speed_reduction_on_warning": 0.10, "speed_reduction_on_critical": 0.20 }, "jam_detection": { "current_spike_threshold_percent": 150, "rise_time_window_sec": 2.0, "reversal_duration_sec": 5, "reversal_speed_mps": 0.5 }, "slip_detection": { "product_lag_threshold_mps": 0.2, "slip_speed_reduction_factor": 0.30, "recovery_ramp_rate_mps_per_sec": 0.1 } }, "safety": { "emergency_stop_response_sec": 0.5, "motor_overheat_threshold_c": 80.0, "brake_current_check_ma": 100, "brake_current_timeout_sec": 5, "e_stop_solenoid_de_energize_ms": 10, "downstream_backup_speed_reduction": 0.50, "encoder_loss_safe_speed_mps": 0.3 } } ``` --- ## 8. Implementation Checklist ### Pre-Commissioning (Days 1–2) **Mechanical** - [ ] Belt tension verified with torque wrench; tension = 50–100 N at midspan (depends on load) - [ ] Pulley alignment checked with laser alignment tool; <1 mm runout acceptable - [ ] Bearings lubricated per OEM spec; no grinding noise at full speed - [ ] Mechanical brake tested manually; application force >500 N holds belt against weight - [ ] Brake release solenoid bench-tested; pulls plunger at 24 VDC ±10% **Electrical** - [ ] 3-phase motor phase sequence verified (A→B→C rotation direction correct) - [ ] VFD motor output terminals checked after soft-start board (should see PWM signal ~10 kHz) - [ ] Current transformer secondary grounded (CT secondary short-circuit protection) - [ ] Encoder connection to PLC verified; all 4 lines (power, GND, A, B) seated - [ ] E-stop circuit hardwired directly to brake solenoid AND VFD stop input **Software** - [ ] Speed setpoint limits set: 0.1–2.0 m/s in HMI - [ ] Ramp rate constants uploaded: RAMP_RATE_UP=0.2, RAMP_RATE_DOWN=0.3 - [ ] All alarm thresholds entered: warning 85%, critical 100%, jam 150% - [ ] Manual speed control tested: slider 0–2 m/s → VFD frequency output changes linearly ### Hot Commissioning — Day 3 (No-Load Startup) **Initial VFD Test (Belt Stationary)** - [ ] Power VFD; confirm LED "ready" indicator - [ ] Set frequency command to 10 Hz; verify motor doesn't rotate (no load/brake applied) - [ ] Ramp frequency to 30 Hz; listen for smooth motor tone (no crackling) - [ ] Reduce to 0 Hz; confirm smooth coast to stop (no clunking) **Brake Solenoid Test** - [ ] Energize solenoid with 24 VDC; confirm clunking noise (plunger pulls) - [ ] De-energize; confirm spring action (belt held by friction) - [ ] Verify current draw changes <50 mA on/off transition **Speed Control Test (Belt Moving, No Product)** - [ ] Release brake and start VFD at 10 Hz (0.33 m/s) - [ ] Gradually increase frequency; verify speed increases smoothly - [ ] At 30 Hz (1.0 m/s), verify speed stabilizes within ±5% - [ ] Check encoder accuracy: count pulses; calculate speed; compare to displaywelcome ### Full Load Commissioning — Days 4–5 (With Products) **Ramp-Up Phase Test** - [ ] Start conveyor at low speed (0.3 m/s); manually place product on belt - [ ] Verify product accelerates with belt; product acceleration <0.5 m/s² (no slip visible) - [ ] Increase speed to 1.0 m/s; verify smooth ramp over 8 seconds - [ ] Monitor current: should not exceed 50% during no-load acceleration **Load Test** - [ ] Run conveyor empty; measure baseline current (should be ~20–30 A) - [ ] Add product weight; gradually increase to design load - [ ] At 85% current (127 A), verify system reduces speed by 10% and logs warning - [ ] At 100% current (150 A), verify system ramps to stop and transitions to OVERLOAD state **Jam Test (Controlled)** - [ ] Block belt with lever; motor current spikes - [ ] Verify current rise >150% within 2 seconds → jam detection triggers - [ ] Verify belt reverses at 0.5 m/s for 5 seconds - [ ] Verify jam reversal completes; belt stops and waits for manual reset **Slip Simulation (if vision available)** - [ ] Load conveyor with low-friction product (plastic parts) - [ ] Accelerate to 1.5 m/s; observe product slipping visibly behind belt - [ ] Camera detects product speed <belt speed by 0.2 m/s - [ ] Verify system reduces speed by 30% automatically - [ ] Verify speed recovers gradually when slip ceases **E-Stop Response Test** - [ ] Belt running at 1.0 m/s - [ ] Press E-stop button - [ ] Measure time to stop: should be <5 seconds (mechanical friction deceleration) - [ ] Verify solenoid de-energizes (heard release sound) - [ ] Verify brake holds (manual push on belt should not move) ### Baseline Data (Days 6–7) **24-Hour Run Recording** - [ ] Log all transitions: IDLE → STARTING → RUNNING → OVERLOAD → IDLE - [ ] Capture CSV: timestamp, speed_setpoint, speed_actual, motor_current, state - [ ] Calculate: ramp time (should be consistent ≤10 sec), settling time (< 20 sec) - [ ] Measure power consumption during 8-hour production run --- ## 9. Expected Performance ### Steady-State Speed Regulation | **Metric** | **Target** | **Acceptable** | **Measured** | |---|---|---|---| | Speed setpoint accuracy | ±2% | ±5% | _______ | | Speed ripple (oscillation) | <±0.02 m/s | <±0.05 m/s | _______ | | Response to 20% load step | Settle <5 sec | Settle <15 sec | _______ | | Motor current baseline | 25 A ±5 A | 20–35 A | _______ | | Proportional band width | ±0.15 m/s | ±0.30 m/s | _______ | ### Ramp-Up Phase (0→1.0 m/s) | **Metric** | **Target** | **Acceptable** | **Measured** | |---|---|---|---| | Total ramp time | 6–8 sec | <15 sec | _______ | | Smoothness (no jerks) | Continuous | <2 visible jerks | _______ | | Product acceleration | <0.5 m/s² | <0.8 m/s² | _______ | | Overshoot above setpoint | None | <5% | _______ | | Current during ramp | <40 A | <60 A | _______ | ### Load Handling | **Metric** | **Target** | **Acceptable** | **Measured** | |---|---|---|---| | Load warning trigger | 85% I_rated (127 A) | ±5% | _______ | | Load critical trigger | 100% I_rated (150 A) | ±5% | _______ | | Speed reduction response | <3 sec | <10 sec | _______ | | Jam detection current | 150% I_rated spike | ±10% | _______ | | Jam reversal duration | 5 sec ±0.5 sec | 4–6 sec | _______ | ### System Reliability | **Metric** | **Target** | **Measured** | |---|---|---| | Uptime (mean time between failures) | >200 hours | _______ | | False jam detections per 100 hr | <2 | _______ | | Encoder error rate | <0.1% | _______ | | Motor thermal stability | ±3°C variation | _______ | --- ## 10. Advanced Variations ### 10.1 Multi-Zone Conveyor (Coordinated Speed) If Line A feeds into Line B: - Measure queue depth between zones (proximity sensors) - If queue at junction >threshold, reduce downstream speed - Feedforward upstream queue depth into speed setpoint calculation ### 10.2 Dynamic Load Balancing (Multiple Parallel Conveyors) - Monitor load (current) on 4 parallel conveyor lines - Distribute incoming product evenly: if Line A has high load, reduce speed; if Line B idle, increase speed - Centralized load-balancing algorithm ### 10.3 Predictive Maintenance - Track motor current trend over weeks - If current increases >10% at same load → bearing wear; schedule inspection - If encoder slip events increase → belt tension drifting; schedule tension check ### 10.4 Product Speed Matching (With Downstream Assembly) - If downstream robot arm speed = 1.2 m/s, conveyor automatically matches 1.2 m/s - Reduces product jitter at handoff - Requires vision feedback or communication link to downstream PLC --- **Document Version:** 1.0 **Last Updated:** 2026-04-13 **Status:** Ready for Production **Approval:** Manufacturing Engineering (pending)

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library