Escalator Load Control — PLC Control Template

Shared by TSIMEREZIVO Team · 4 Oct 2026 · 37 views

# Escalator Load Control — Usage Guide ## Overview Safety-oriented escalator supervision template that trips on overload, motor overcurrent, or E-stop and applies the brake until a manual reset is performed. ## Commissioning 1. Verify calibrated load and current inputs 2. Confirm overload and overcurrent thresholds match OEM limits 3. Test brake application and reset sequence with machine isolated --- ## Control Logic — Vendor-Agnostic Pseudocode # Escalator Load Control — Logic ## Standards: IEC 61131-3 | EN 115 | IEC 61508 SIL1 ## Scan Rate: 50ms | Pattern: load supervision with overcurrent trip ``` ROUTINE: EscalatorLoadControl SCAN_RATE: 50ms // SECTION 1 — LOAD AND CURRENT SUPERVISION OVERLOAD := LOAD_PV >= LOAD_TRIP_SP OVERCURRENT := MOTOR_AMPS >= MOTOR_AMP_TRIP_SP // SECTION 2 — RUN CONTROL IF START_CMD AND NOT SAFETY_TRIP THEN RUN_CMD := TRUE END_IF IF STOP_CMD THEN RUN_CMD := FALSE END_IF // SECTION 3 — SAFETY TRIP IF OVERLOAD OR OVERCURRENT OR ESTOP_ACTIVE THEN RUN_CMD := FALSE BRAKE_CMD := TRUE SAFETY_TRIP := TRUE END_IF IF RESET_CMD AND NOT OVERLOAD AND NOT OVERCURRENT AND NOT ESTOP_ACTIVE THEN BRAKE_CMD := FALSE SAFETY_TRIP := FALSE END_IF // SECTION 4 — ALARMS IF OVERLOAD THEN SET_ALARM(ALM_OVERLOAD, HIGH) END_IF IF OVERCURRENT THEN SET_ALARM(ALM_OVERCURRENT, HIGH) END_IF IF ESTOP_ACTIVE THEN SET_ALARM(ALM_ESTOP, CRITICAL) END_IF // SECTION 5 — HMI HMI_LOAD := LOAD_PV HMI_AMPS := MOTOR_AMPS HMI_TRIP := SAFETY_TRIP END_ROUTINE ``` --- ## Tag List ```csv Tag Name,Description,Data Type,Direction,Engineering Unit,Range Min,Range Max,Default Value,Address START_CMD,Escalator Start Command,BOOL,input,,,,FALSE, STOP_CMD,Escalator Stop Command,BOOL,input,,,,FALSE, RESET_CMD,Safety Reset Command,BOOL,input,,,,FALSE, ESTOP_ACTIVE,E-Stop Active,BOOL,input,,,,FALSE,DI:0:0.0 LOAD_PV,Measured Escalator Load,REAL,input,kg,0,5000,0,AI:0:0.0 MOTOR_AMPS,Escalator Motor Current,REAL,input,A,0,200,0,AI:0:0.1 LOAD_TRIP_SP,Load Trip Setpoint,REAL,internal,kg,0,5000,2500, MOTOR_AMP_TRIP_SP,Motor Current Trip Setpoint,REAL,internal,A,0,200,120, OVERLOAD,Overload Condition,BOOL,calculated,,,,FALSE, OVERCURRENT,Overcurrent Condition,BOOL,calculated,,,,FALSE, RUN_CMD,Escalator Run Command,BOOL,output,,,,FALSE,DO:1:0.0 BRAKE_CMD,Escalator Brake Command,BOOL,output,,,,FALSE,DO:1:0.1 SAFETY_TRIP,Safety Trip Latched,BOOL,internal,,,,FALSE, ALM_OVERLOAD,Escalator Overload Alarm,BOOL,calculated,,,,FALSE, ALM_OVERCURRENT,Escalator Overcurrent Alarm,BOOL,calculated,,,,FALSE, ALM_ESTOP,E-Stop Alarm,BOOL,calculated,,,,FALSE, HMI_LOAD,HMI: Escalator Load,REAL,output,kg,0,5000,0, HMI_AMPS,HMI: Motor Current,REAL,output,A,0,200,0, HMI_TRIP,HMI: Safety Trip,BOOL,output,,,,FALSE, ``` --- ## Alarm Matrix ```csv Alarm Tag,Condition,Setpoint,Priority,Type,Response,Delay,Auto Acknowledge ALM_ESTOP,ESTOP_ACTIVE = TRUE,N/A,critical,safety,Emergency stop active. Escalator stopped and brake applied.,0s,No ALM_OVERLOAD,LOAD_PV >= LOAD_TRIP_SP,2500kg,high,safety,Passenger load exceeds safe design basis. Escalator stopped pending reset.,0s,No ALM_OVERCURRENT,MOTOR_AMPS >= MOTOR_AMP_TRIP_SP,120A,high,equipment,Drive current above limit. Stop escalator and inspect drivetrain load.,0s,No ```

More like this

Rate, comment, and get full access

Members can download files, rate contributions, and discuss fixes with the engineers who posted them — free.

Join the library