- Read more
Thickener Rake Torque & Underflow Clarity — Control Design
A thickener settling tank, 20–50 m diameter allows coarse solids to settle under gravity while water overflows as clarified product. A rotating rake mechanism slowly scrapes settled solids toward a central pump cone unde…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Flotation Cell Pulp Density & Air Control — Control Design
Froth flotation cells separate valuable minerals sulfides, oxides from gangue worthless rock by floating mineral particles to the surface and collecting froth overflow. Cell performance depends critically on maintaining …
TSIMEREZIVO Team · 35 views · 0 downloads
- Read more
Soft-Start Electronic Motor Ramp — Control Design
Smooth acceleration of 3 phase AC induction motors using solid state soft starter to reduce inrush current, mechanical shock, and transmission wear. Applications: conveyor drive, pump motor, fan, compressor startup, ener…
TSIMEREZIVO Team · 47 views · 0 downloads
- Read more
Injection Mold Cavity Temperature Control — Control Design
Regulate injection mold cavity temperature via circulating heating/cooling water and proportional control valves. Critical for part dimensional stability, surface quality, and cycle time optimization in injection molding…
TSIMEREZIVO Team · 36 views · 0 downloads
- Read more
Batch Reactor Temperature Control — Control Design
Multi stage reaction vessel temperature regulation via jacket heating and cooling water circulation. Typical applications include pharmaceutical synthesis, chemical polymerization, food processing, cosmetics blending.
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Dual Equipment Switchover (Automatic Failover) — Control Design
Switch load automatically from Primary → Secondary motor if Primary fails OR Primary demand exceeds capacity.
TSIMEREZIVO Team · 37 views · 0 downloads
- Read more
Emergency Shutdown (E-Stop) Logic — Control Design
Implement a hardwired emergency stop circuit that cuts power to all dangerous motors/actuators
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Pressure Reducing Valve (Pilot-Operated) — Control Design
Reduce a high pressure supply to a lower, regulated downstream pressure via a pilot operated proportional valve.
TSIMEREZIVO Team · 69 views · 0 downloads
- Read more
Proportional Control Valve Position Feedback Loop — Control Design
Position a proportional control valve spool accurately 0 100% using feedback based regulation. Ensures valve opening matches command despite internal friction and spool nonlinearities.
TSIMEREZIVO Team · 54 views · 0 downloads
- Read more
Flow Control Loop (PID-Based) — Control Design
Maintain constant flow rate via proportional valve position or pump speed modulation. Independent of downstream pressure variations.
TSIMEREZIVO Team · 45 views · 0 downloads
- Read more
Pump Control (Single — On/Off with Protection) — Control Design
Start/stop a single electric motor pump with automatic overload protection, dry run prevention, and fault reporting.
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Pressure Control Loop (PID-Based) — Control Design
Maintain system pressure at setpoint via proportional valve modulation. Prevents overpressure conditions and minimizes pressure oscillations.
TSIMEREZIVO Team · 43 views · 0 downloads
- Read more
Temperature PID Control Loop — Control Design
Precision temperature regulation via proportional integral derivative PID feedback control. Applies 0 100% output modulation to heating or cooling element based on error between setpoint and actual temperature.
TSIMEREZIVO Team · 49 views · 0 downloads
- Read more
Variable Frequency Drive (VFD) Motor Control — Control Design
Modulate AC motor speed via frequency control. Enables energy savings, process precision, and soft start capability.
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Pump Control (Lead/Lag - Duty Cycling) — Control Design
Two identical pumps sharing duty load. Automatically alternates every 24 hours configurable to equalize wear and extend equipment life.
TSIMEREZIVO Team · 50 views · 0 downloads
- Read more
Single Tank Level Control — Control Design
Simple level control for a single tank with pump or valve control. The most fundamental control loop in industrial automation.
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
HVAC Control — AHU and Chiller Plant — Control Design
Building Management System BMS control of an Air Handling Unit AHU and chilled water plant serving a commercial or industrial facility. Covers supply air temperature, mixed air economizer, variable volume supply air, and…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Tank To Tank Transfer — PLC Control Template
Metered transfer between two tanks with permissive gate, volume accumulation, source/destination level cutoffs, and timeout protection. Suitable for: raw material transfers, product blending feeds, CIP chemical dosing ta…
TSIMEREZIVO Team · 43 views · 0 downloads
- Read more
Level Alarm And Control — PLC Control Template
Four tier tank alarm scheme with confirmation delays and hysteresis, combined with simple fill and drain pump control. This template is suited to Siemens STEP 7 / TIA style applications where discrete alarms and on/off c…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Fill Drain Logic — PLC Control Template
Multi mode tank control OFF / MANUAL / AUTO FILL / AUTO DRAIN / BATCH SEQUENCE with dual valve discrepancy monitoring, ISA 88 sequence state machine, fill/drain timeout, and ISA 18.2 alarm hierarchy. Suitable for: proces…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Water Level Pump Control — PLC Control Template
Hysteresis band level control with 4 tier ISA 18.2 alarm hierarchy, 3 point median filtering, wire break detection, leak rate monitoring, and manual/auto mode. Suitable for raw water tanks, buffer tanks, sump wells, cond…
TSIMEREZIVO Team · 98 views · 0 downloads
- Read more
Three Input Permissive Pump — PLC Control Template
Implements the industry standard AND gate permissive pattern with 3 configurable process permissives plus hardwired E Stop and overload, a 5 bit diagnostic word for HMI display, and individual alarm messages per unsatisf…
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Priority Liquid Level — PLC Control Template
3 stage cascaded priority pump control with redundant transmitter selection, runtime equalised pump assignment, hysteresis confirmed staging, and ISA 18.2 alarm hierarchy. Designed for high demand applications: municipal…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Latching Interlock Pump — PLC Control Template
This template implements production grade pump motor control with full IEC 61131 3 seal in latch, 7 condition permissive interlock gate, manual/auto/off mode, hard reset fault latch, star delta soft start sequencing, run…
TSIMEREZIVO Team · 50 views · 0 downloads