Engineering Library
Procedures, PLC and HMI code, drawings, and field-proven fixes shared by working controls and instrumentation engineers. Community contributions publish immediately and can be flagged for review. Membership is free — sign in to download, rate, and contribute.
126 published contributions
- Read more
Membrane Filtration with Automated Backwash Sequencing — Control Design
Operate crossflow ultrafiltration UF or microfiltration MF membrane systems with pressure driven permeate production and air assisted backwashing to restore permeability. Membrane fouling increases transmembrane pressure…
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Multi-Pump Distribution System with Pressure Regulation — Control Design
Manage water distribution from treatment plant to customers via a variable speed pump network . System must maintain constant downstream pressure despite fluctuating demand day: 700 m³/h peak; night: 80 m³/h base . Uses …
TSIMEREZIVO Team · 66 views · 0 downloads
- Read more
Activated Sludge Aeration Basin Control — Control Design
Maintain dissolved oxygen DO setpoint in activated sludge reactor tank through automatic aeration control. The aeration basin is the heart of wastewater treatment , where microorganisms consume organic pollutants BOD und…
TSIMEREZIVO Team · 45 views · 0 downloads
- Read more
Aeration Basin Control — Control Design
Dissolved oxygen DO control in an activated sludge aeration basin for biological wastewater treatment. Covers blower/diffuser DO control, MLSS mixed liquor suspended solids monitoring, ammonia based aeration control ABAC…
TSIMEREZIVO Team · 47 views · 0 downloads
- Read more
Pump Station Control — Control Design
Automated control of a multi pump wet well station for raw sewage, stormwater, or potable water transfer. Covers duty/standby pump sequencing, wet well level control, and dry run protection.
TSIMEREZIVO Team · 51 views · 0 downloads
- Read more
Load / Frequency Control (AGC / LFC) — Control Design
Automatic Generation Control AGC and Load Frequency Control LFC for a generating unit participating in primary, secondary, and tertiary frequency response. Covers Area Control Error ACE computation, generation ramp manag…
TSIMEREZIVO Team · 37 views · 0 downloads
- Read more
Pulverized Coal Mill Outlet (PA) Flow Control — Control Design
Regulate primary air PA flow and temperature from the coal mill to maintain consistent coal in air concentration fuel feed to the furnace. The mill grinds raw coal into powder ~200 µm , mixes with hot air to fluidize par…
TSIMEREZIVO Team · 54 views · 0 downloads
- Read more
Economizer Outlet Temperature Control — Control Design
Maintain boiler feedwater temperature exiting the economizer exhaust gas heat exchanger at 210–220°C to preheat incoming cold feed water from the deaerator 160°C . This recovers 10–15% of the boiler's thermal energy that…
TSIMEREZIVO Team · 48 views · 0 downloads
- Read more
Air/Fuel Ratio Trim Cascade Control — Control Design
Fine tune air/fuel ratio lambda for optimal combustion energy recovery while meeting NOₓ emissions limits. This is the secondary loop extension to Template 01 Furnace Combustion Pressure , explicitly managing stoichiomet…
TSIMEREZIVO Team · 64 views · 0 downloads
- Read more
Boiler Feedwater Pump Pressure Control — Control Design
Maintain boiler feedwater pump discharge pressure at precisely 180–200 bar to overcome boiler steam drum pressure 175 bar at design plus pipe friction losses ~15–20 bar while minimizing energy waste. Too high = relief va…
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Deaerator Heater Level Control — Control Design
Maintain the deaerator feed water tank at a constant level typically 50–60% of vessel to ensure reliable suction pressure for the boiler feedwater pump NPSH—Net Positive Suction Head availability . The deaerator also hea…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Main Condenser Pressure Control — Control Design
Maintain the main condenser absolute pressure at 0.08 bar 80 mbar to maximize turbine expansion and power output. The condenser converts exhaust steam from the turbine back to liquid water through cooling. Lower absolute…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Furnace Combustion Pressure Control (O₂ Trim) — Control Design
Maintain furnace combustion air pressure within ±0.5 inches water column ±125 Pa setpoint
TSIMEREZIVO Team · 42 views · 0 downloads
- Read more
Gas Separation Vessel — Control Design
Three phase separator removes liquids oil + water from raw gas stream under subsonic conditions. Liquid level is controlled via dump valve to prevent slugging downstream compressor inlet while maintaining interface betwe…
TSIMEREZIVO Team · 51 views · 0 downloads
- Read more
Crude Oil Tank Level & Custody Transfer Metering — Control Design
Automatically measure crude oil tank inventory and compute net barrels accounting for temperature, API gravity, water content for custody transfer ownership handoff between operator and buyer . Tank level measurement mus…
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Gas Compression & Discharge Throttling — Control Design
Operate centrifugal or reciprocating gas compressor to maintain pipeline discharge pressure setpoint typically 800–1500 psia while protecting equipment from surge compressor pre surge condition and limiting discharge tem…
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Wellhead Pressure Management & Production Optimization — Control Design
Automatically regulate wellhead backpressure tubing head pressure to optimize production rate while protecting subsurface equipment and preventing sand production. Most oil/gas wells produce under pressure differential: …
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Thickener Rake Torque & Underflow Clarity — Control Design
A thickener settling tank, 20–50 m diameter allows coarse solids to settle under gravity while water overflows as clarified product. A rotating rake mechanism slowly scrapes settled solids toward a central pump cone unde…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Crusher Jaw Gap & Feed Rate Optimization — Control Design
A jaw crusher belt fed ore hopper → primary crusher → stockpile must maintain optimal jaw gap 2–6 cm typical to maximize throughput while preventing overload motor stall, frame damage . Jaw gap is adjustable via eccentri…
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Packaging Line Sequencing & Coordination — Control Design
Synchronize multi zone conveyor line with intermittent and continuous equipment feeders, labelers, casepacker, palletizer using zone based state machines and encoder based product tracking. Ensures smooth flow, prevents …
TSIMEREZIVO Team · 42 views · 0 downloads
- Read more
Vision-Guided Inspection & QA — Control Design
Automated optical inspection of manufactured parts using machine vision camera + image processing to detect defects, classify products, and trigger downstream quality actions accept/reject/rework . Applications: electron…
TSIMEREZIVO Team · 42 views · 0 downloads
- Read more
Pneumatic Valve Proportional Actuation — Control Design
Proportional control of directional control valves solenoid piloted spool valves using pulse width modulation PWM to achieve smooth actuation of pneumatic cylinders. Applications: press control, clamping, tool changer ac…
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Robotic Arm Multi-Axis Position Tracking — Control Design
Coordinate multi axis typically 6 robotic arm positioning via simultaneous inverse kinematics, proportional servo valve control, and position feedback from joint encoders. Applications: welding, material handling,assembl…
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Injection Mold Cavity Temperature Control — Control Design
Regulate injection mold cavity temperature via circulating heating/cooling water and proportional control valves. Critical for part dimensional stability, surface quality, and cycle time optimization in injection molding…
TSIMEREZIVO Team · 36 views · 0 downloads
Worked on a project? Share what you learned.
Upload procedures, code, drawings — or post the fix that took you a day to find. Your experience is the library.
Create a free account