Engineering Library
Procedures, PLC and HMI code, drawings, and field-proven fixes shared by working controls and instrumentation engineers. Community contributions publish immediately and can be flagged for review. Membership is free — sign in to download, rate, and contribute.
126 published contributions
- Read more
Ladder Logic (LD) Programming — Engineering Guide
Ladder Logic LD Programming
TSIMEREZIVO Team · 52 views · 0 downloads
- Read more
Boiler Drum Level — 3-Element Control — Engineering Guide
Boiler Drum Level — 3 Element Control
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Modbus TCP Flow Meter Integration — Engineering Guide
Modbus TCP Flow Meter Integration
TSIMEREZIVO Team · 52 views · 0 downloads
- Read more
Conveyor Pull-Cord Safety Circuit — Engineering Guide
Conveyor Pull Cord Safety Circuit
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
I/O Rack & Module Mapping — Engineering Guide
I/O Rack & Module Mapping
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Boiler Feedwater Pump Pressure Control — Control Design
Maintain boiler feedwater pump discharge pressure at precisely 180–200 bar to overcome boiler steam drum pressure 175 bar at design plus pipe friction losses ~15–20 bar while minimizing energy waste. Too high = relief va…
TSIMEREZIVO Team · 43 views · 0 downloads
- Read more
Deaerator Heater Level Control — Control Design
Maintain the deaerator feed water tank at a constant level typically 50–60% of vessel to ensure reliable suction pressure for the boiler feedwater pump NPSH—Net Positive Suction Head availability . The deaerator also hea…
TSIMEREZIVO Team · 45 views · 0 downloads
- Read more
Main Condenser Pressure Control — Control Design
Maintain the main condenser absolute pressure at 0.08 bar 80 mbar to maximize turbine expansion and power output. The condenser converts exhaust steam from the turbine back to liquid water through cooling. Lower absolute…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Superheater Outlet Temperature Control (Spray Water Attemperator) — Control Design
Maintain superheated steam outlet temperature at exactly setpoint ±3°C typical using proportional
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Soft-Start Electronic Motor Ramp — Control Design
Smooth acceleration of 3 phase AC induction motors using solid state soft starter to reduce inrush current, mechanical shock, and transmission wear. Applications: conveyor drive, pump motor, fan, compressor startup, ener…
TSIMEREZIVO Team · 47 views · 0 downloads
- Read more
Pneumatic Valve Proportional Actuation — Control Design
Proportional control of directional control valves solenoid piloted spool valves using pulse width modulation PWM to achieve smooth actuation of pneumatic cylinders. Applications: press control, clamping, tool changer ac…
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Emergency Shutdown (E-Stop) Logic — Control Design
Implement a hardwired emergency stop circuit that cuts power to all dangerous motors/actuators
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Proportional Control Valve Position Feedback Loop — Control Design
Position a proportional control valve spool accurately 0 100% using feedback based regulation. Ensures valve opening matches command despite internal friction and spool nonlinearities.
TSIMEREZIVO Team · 53 views · 0 downloads
- Read more
Temperature PID Control Loop — Control Design
Precision temperature regulation via proportional integral derivative PID feedback control. Applies 0 100% output modulation to heating or cooling element based on error between setpoint and actual temperature.
TSIMEREZIVO Team · 48 views · 0 downloads
- Read more
Pump Control (Lead/Lag - Duty Cycling) — Control Design
Two identical pumps sharing duty load. Automatically alternates every 24 hours configurable to equalize wear and extend equipment life.
TSIMEREZIVO Team · 49 views · 0 downloads
- Read more
Single Tank Level Control — Control Design
Simple level control for a single tank with pump or valve control. The most fundamental control loop in industrial automation.
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
FAT Procedure Template — Full Coverage
Project: ______________ System: ______________ FAT No: FAT ____
TSIMEREZIVO Team · 55 views · 0 downloads
- Read more
I/O Schedule Template
Maps every field signal to a controller channel. The master reference for wiring, marshalling, and program development.
TSIMEREZIVO Team · 45 views · 0 downloads
- Read more
Tank To Tank Transfer — PLC Control Template
Metered transfer between two tanks with permissive gate, volume accumulation, source/destination level cutoffs, and timeout protection. Suitable for: raw material transfers, product blending feeds, CIP chemical dosing ta…
TSIMEREZIVO Team · 42 views · 0 downloads
- Read more
Liquid Temperature PID — PLC Control Template
PID temperature control with multi sensor averaging, split range heat/cool valve output, anti windup, derivative on PV no setpoint kick , overtemperature safety trip SIL1 , and ISA 18.2 alarm hierarchy.
TSIMEREZIVO Team · 34 views · 0 downloads
- Read more
Liquid Filling Machine — PLC Control Template
Count by volume filling line control. A bottle present sensor stops the conveyor, a fill valve opens until the target volume is reached via pulse counting , then volume is validated against tolerance and the bottle is ei…
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Level Alarm And Control — PLC Control Template
Four tier tank alarm scheme with confirmation delays and hysteresis, combined with simple fill and drain pump control. This template is suited to Siemens STEP 7 / TIA style applications where discrete alarms and on/off c…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Fill Drain Logic — PLC Control Template
Multi mode tank control OFF / MANUAL / AUTO FILL / AUTO DRAIN / BATCH SEQUENCE with dual valve discrepancy monitoring, ISA 88 sequence state machine, fill/drain timeout, and ISA 18.2 alarm hierarchy. Suitable for: proces…
TSIMEREZIVO Team · 38 views · 0 downloads
- Read more
Dam Gate 5 Alarm Levels — PLC Control Template
Flood management template with five escalating alarm levels and corresponding gate position commands. Designed for reservoir outlet gates, spillway control, and storm water retention systems where simple, deterministic s…
TSIMEREZIVO Team · 36 views · 0 downloads
Worked on a project? Share what you learned.
Upload procedures, code, drawings — or post the fix that took you a day to find. Your experience is the library.
Create a free account