Engineering Library
Procedures, PLC and HMI code, drawings, and field-proven fixes shared by working controls and instrumentation engineers. Community contributions publish immediately and can be flagged for review. Membership is free — sign in to download, rate, and contribute.
126 published contributions
- Read more
Boiler Drum Level — 3-Element Control — Engineering Guide
Boiler Drum Level — 3 Element Control
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Importing & Creating Tags — Engineering Guide
Importing & Creating Tags
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Chemical Disinfection & Residual Monitoring — Control Design
Automatically inject chlorine or ozone into treated water to inactivate pathogens bacteria, viruses, protozoa . Maintain residual disinfectant 0.2–0.5 mg/L free chlorine throughout distribution system. Continuously monit…
TSIMEREZIVO Team · 42 views · 0 downloads
- Read more
Activated Sludge Aeration Basin Control — Control Design
Maintain dissolved oxygen DO setpoint in activated sludge reactor tank through automatic aeration control. The aeration basin is the heart of wastewater treatment , where microorganisms consume organic pollutants BOD und…
TSIMEREZIVO Team · 45 views · 0 downloads
- Read more
Pump Station Control — Control Design
Automated control of a multi pump wet well station for raw sewage, stormwater, or potable water transfer. Covers duty/standby pump sequencing, wet well level control, and dry run protection.
TSIMEREZIVO Team · 51 views · 0 downloads
- Read more
Turbine Governor Control — Control Design
Speed and load control of a steam or gas turbine via the electro hydraulic governor. Covers isochronous speed control islanding , droop control grid connected , acceleration limiting, overspeed protection, and valve posi…
TSIMEREZIVO Team · 97 views · 0 downloads
- Read more
Boiler Drum Level Control (3-Element Control) — Control Design
Three element feedwater control for boiler drum level. Most safety critical control in power plants.
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Pulverized Coal Mill Outlet (PA) Flow Control — Control Design
Regulate primary air PA flow and temperature from the coal mill to maintain consistent coal in air concentration fuel feed to the furnace. The mill grinds raw coal into powder ~200 µm , mixes with hot air to fluidize par…
TSIMEREZIVO Team · 53 views · 0 downloads
- Read more
Economizer Outlet Temperature Control — Control Design
Maintain boiler feedwater temperature exiting the economizer exhaust gas heat exchanger at 210–220°C to preheat incoming cold feed water from the deaerator 160°C . This recovers 10–15% of the boiler's thermal energy that…
TSIMEREZIVO Team · 47 views · 0 downloads
- Read more
Air/Fuel Ratio Trim Cascade Control — Control Design
Fine tune air/fuel ratio lambda for optimal combustion energy recovery while meeting NOₓ emissions limits. This is the secondary loop extension to Template 01 Furnace Combustion Pressure , explicitly managing stoichiomet…
TSIMEREZIVO Team · 61 views · 0 downloads
- Read more
Main Condenser Pressure Control — Control Design
Maintain the main condenser absolute pressure at 0.08 bar 80 mbar to maximize turbine expansion and power output. The condenser converts exhaust steam from the turbine back to liquid water through cooling. Lower absolute…
TSIMEREZIVO Team · 46 views · 0 downloads
- Read more
Superheater Outlet Temperature Control (Spray Water Attemperator) — Control Design
Maintain superheated steam outlet temperature at exactly setpoint ±3°C typical using proportional
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Furnace Combustion Pressure Control (O₂ Trim) — Control Design
Maintain furnace combustion air pressure within ±0.5 inches water column ±125 Pa setpoint
TSIMEREZIVO Team · 41 views · 0 downloads
- Read more
Subsea Umbilical Fault Isolation — Control Design
A subsea production manifold is connected to topside via umbilical hydraulic control lines, power cables, fiber optics bundled . If umbilical ruptures, hydraulic pressure is lost, and all remotely operated valves ROVs go…
TSIMEREZIVO Team · 44 views · 0 downloads
- Read more
Gas Separation Vessel — Control Design
Three phase separator removes liquids oil + water from raw gas stream under subsonic conditions. Liquid level is controlled via dump valve to prevent slugging downstream compressor inlet while maintaining interface betwe…
TSIMEREZIVO Team · 50 views · 0 downloads
- Read more
Pipeline Flow Metering & Leak Detection — Control Design
Continuously measure crude/gas flow through transmission pipeline orifice plate, turbine, or ultrasonic meter and detect leaks by comparing expected flow from surface + subsurface meters against actual outlet flow. A 2% …
TSIMEREZIVO Team · 36 views · 0 downloads
- Read more
Crude Oil Tank Level & Custody Transfer Metering — Control Design
Automatically measure crude oil tank inventory and compute net barrels accounting for temperature, API gravity, water content for custody transfer ownership handoff between operator and buyer . Tank level measurement mus…
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Gas Compression & Discharge Throttling — Control Design
Operate centrifugal or reciprocating gas compressor to maintain pipeline discharge pressure setpoint typically 800–1500 psia while protecting equipment from surge compressor pre surge condition and limiting discharge tem…
TSIMEREZIVO Team · 40 views · 0 downloads
- Read more
Wellhead Pressure Management & Production Optimization — Control Design
Automatically regulate wellhead backpressure tubing head pressure to optimize production rate while protecting subsurface equipment and preventing sand production. Most oil/gas wells produce under pressure differential: …
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Proportional Control Valve Position Feedback Loop — Control Design
Position a proportional control valve spool accurately 0 100% using feedback based regulation. Ensures valve opening matches command despite internal friction and spool nonlinearities.
TSIMEREZIVO Team · 53 views · 0 downloads
- Read more
Pump Control (Single — On/Off with Protection) — Control Design
Start/stop a single electric motor pump with automatic overload protection, dry run prevention, and fault reporting.
TSIMEREZIVO Team · 39 views · 0 downloads
- Read more
Pressure Control Loop (PID-Based) — Control Design
Maintain system pressure at setpoint via proportional valve modulation. Prevents overpressure conditions and minimizes pressure oscillations.
TSIMEREZIVO Team · 43 views · 0 downloads
- Read more
Pump Control (Lead/Lag - Duty Cycling) — Control Design
Two identical pumps sharing duty load. Automatically alternates every 24 hours configurable to equalize wear and extend equipment life.
TSIMEREZIVO Team · 49 views · 0 downloads
- Read more
Single Tank Level Control — Control Design
Simple level control for a single tank with pump or valve control. The most fundamental control loop in industrial automation.
TSIMEREZIVO Team · 38 views · 0 downloads
Worked on a project? Share what you learned.
Upload procedures, code, drawings — or post the fix that took you a day to find. Your experience is the library.
Create a free account